Advertisement

MODEL:
TLS1/CAR281
TLS1/CAR282
CODE:
010663/TLS1
KOLVER S.r.l.
declare that this unit for TLS1 arm is in conformity with the following standards and other normative
documents:
2006/42/CE, LVD 2014/35/UE, EMCD 2014/30/UE,
61000-6-2, EN 61000-6-4.
.It is also in conformity with RoHS III normative (2011/65/UE and following 2015/863).
Name:
Position:
Thiene, January 1st 2022
IDENTIFICATION DATA OF THE MANUFACTURER
36016 THIENE (VI) ITALIA
IDENTIFICATION DATA OF THE PRODUCT
U
TLS1/CAR501
010664/TLS1
010665/TLS1
TECHNICAL DATA OF THE PRODUCT
SUPPLY VOLTAGE: 12V DC
DIMENSIONS: 170 x 100 x 35 mm
DECLARATION OF CONFORMITY
Giovanni Colasante
General Manager
Person authorized to compile the technical file in Kolver
MANUAL
TLS1 2.03
KOLVER S.r.l.
VIA M. CORNER, 19/21
TLS1/CAR502
TLS1/LINAR1
010666/TLS1
010681/TLS1
WEIGHT: 0,5 Kg
EN 62841-2-2:2014, EN 62841-1: 2015
TLS1/LINAR2
TLS1/LINART
010682/TLS1
010683/TLS1
, EN 60204-1,
Giovanni Colasante
SAR/XYZ/TLS1
010690/XYZ-TLS1
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TLS 1 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kolver TLS 1 Series

  • Page 1 , EN 60204-1, 61000-6-2, EN 61000-6-4. .It is also in conformity with RoHS III normative (2011/65/UE and following 2015/863). Name: Giovanni Colasante Position: General Manager Person authorized to compile the technical file in Kolver Thiene, January 1st 2022 Giovanni Colasante...
  • Page 2 Please refer to the I/O instructions in this manual and contact Kolver for further assistance. NOTE: When using a PLC or a non-Kolver torque controller, it is imperative to make the correct connections, as improper wiring may damage the TLS1 and/or your torque controller.
  • Page 3 USAGE Turn the unit on through the ON/OFF button on the front panel. K o l v e r S . r . l . T L S V e r s i o n v 2 . 0 3 l o a d i n g .
  • Page 4: Program Menu

    MAIN MENU To enter the menu press ESC for 2 seconds. then press OK (the symbol  will Select the line by pressing turn into ). Press to select the required value and then confirm through OK (or ESC if you don’t want to save the value). Repeat these operations for all the parameters you wish to set and then push ESC to return to the main screen.
  • Page 5 4) Length Tol. (Length Tolerance): you can set a tolerance value (± 1 mm) of length measurement. This range can be set from 1 to 200 mm (resolution 1 mm). Press OK to confirm. In case of LINART, this parameter will be ANGLE1 and it will be the tolerance of the Angle1 (see point 5) referring to the Sensor.
  • Page 6: Options Menu

    OPTIONS MENU - - - - M E N U - O P T I O N S - - - - c h a n g e E S C q u i t  1 ) U n i t m o d e l : K D U C E R ...
  • Page 7 SETTING OF THE POSITION SENSOR (LINAR arm only) After selecting the arm model you are going to use (Options Menu, point 1), you have to check the correct position of the sensor: 1. Enter in Options Menu, go to point 7 (Sensor Position) 2.
  • Page 8 PLC INSTRUCTIONS On the P1 I/O connector: • Supply 24 VDC constantly to Pin 1 and connect the negative (ground) terminal to Pin 5. This power source should be the same as the one that powers the output signals of your PLC. •...
  • Page 9 Vers. 070524...
  • Page 10 INPUT: this pin gives TLS1 the right tension for leds and output signals. The +24V SIGNAL maximum tension must be 24V 400mA. OUTPUT: special output for sending the “disable screwdriver” signal to Kolver controllers when the arm is out of position. STOP MOTOR OUT DO NOT USE WITH PLC (use the POSITION NOK active signal on P2) INPUT: NPN Screw OK signal.
  • Page 11 • CONNECTOR P2 – 7 pin NAME FUNCTION OUTPUT POSITION The screwdriver is NOT located on the correct screw. POSITION The screwdriver is located on the correct screw. PROGRAM END The required number of screws in the program have been completed. SCREW NOK This signal re-routes the signal from P1 - 4.
  • Page 12 • CONNECTOR P3 NAME FUNCTION INPUT INPUT 1 Pin to select the Program 1 INPUT 2 Pin to select the Program 2 INPUT 3 Pin to select the Program 3 INPUT 4 Pin to select the Program 4 INPUT 5 Pin to select the Program 5 INPUT 6 Pin to select the Program 6...
  • Page 13 SERIAL PRINT: On Connector P3, there is a RS232 pin for serial transmission: P3: PIN 6 = TX, PIN 7 = GND You can print on PC (for example through Hyper Terminal programs) or printer (for example our printer PRNTR1) the results of each screw done. The transmission characteristics are: 9600 (bits per second), 8 (data bits), n (no parity), 1 (bits stop 1).
  • Page 14: Exploded View

    EXPLODED VIEW SPARE PARTS Position Description Quantity Code Membrane TLS 1 896001 Upper panel TLS 1 896002 Spacer 15mm dest4.8mm 890004/T Connector 12 poli spacing 3,50 – F 890009 Connector F 7 pin spacing 3,50 – F 891030 Screw 3x5 872443 Connector I/O 5 pin spacing 3,50 –...
  • Page 15 7. No one, whether an agent, servant or employee of KOLVER, is authorized to add to or modify the terms of this limited guarantee in any way. However it’s possible to extend the warranty with an extra cost.

Table of Contents