Page 1
, EN 60204-1, 61000-6-2, EN 61000-6-4. .It is also in conformity with RoHS III normative (2011/65/UE and following 2015/863). Name: Giovanni Colasante Position: General Manager Person authorized to compile the technical file in Kolver Thiene, January 1st 2022 Giovanni Colasante...
Page 2
Please refer to the I/O instructions in this manual and contact Kolver for further assistance. NOTE: When using a PLC or a non-Kolver torque controller, it is imperative to make the correct connections, as improper wiring may damage the TLS1 and/or your torque controller.
Page 3
USAGE Turn the unit on through the ON/OFF button on the front panel. K o l v e r S . r . l . T L S V e r s i o n v 2 . 0 3 l o a d i n g .
MAIN MENU To enter the menu press ESC for 2 seconds. then press OK (the symbol will Select the line by pressing turn into ). Press to select the required value and then confirm through OK (or ESC if you don’t want to save the value). Repeat these operations for all the parameters you wish to set and then push ESC to return to the main screen.
Page 5
4) Length Tol. (Length Tolerance): you can set a tolerance value (± 1 mm) of length measurement. This range can be set from 1 to 200 mm (resolution 1 mm). Press OK to confirm. In case of LINART, this parameter will be ANGLE1 and it will be the tolerance of the Angle1 (see point 5) referring to the Sensor.
OPTIONS MENU - - - - M E N U - O P T I O N S - - - - c h a n g e E S C q u i t 1 ) U n i t m o d e l : K D U C E R ...
Page 7
SETTING OF THE POSITION SENSOR (LINAR arm only) After selecting the arm model you are going to use (Options Menu, point 1), you have to check the correct position of the sensor: 1. Enter in Options Menu, go to point 7 (Sensor Position) 2.
Page 8
PLC INSTRUCTIONS On the P1 I/O connector: • Supply 24 VDC constantly to Pin 1 and connect the negative (ground) terminal to Pin 5. This power source should be the same as the one that powers the output signals of your PLC. •...
Page 10
INPUT: this pin gives TLS1 the right tension for leds and output signals. The +24V SIGNAL maximum tension must be 24V 400mA. OUTPUT: special output for sending the “disable screwdriver” signal to Kolver controllers when the arm is out of position. STOP MOTOR OUT DO NOT USE WITH PLC (use the POSITION NOK active signal on P2) INPUT: NPN Screw OK signal.
Page 11
• CONNECTOR P2 – 7 pin NAME FUNCTION OUTPUT POSITION The screwdriver is NOT located on the correct screw. POSITION The screwdriver is located on the correct screw. PROGRAM END The required number of screws in the program have been completed. SCREW NOK This signal re-routes the signal from P1 - 4.
Page 12
• CONNECTOR P3 NAME FUNCTION INPUT INPUT 1 Pin to select the Program 1 INPUT 2 Pin to select the Program 2 INPUT 3 Pin to select the Program 3 INPUT 4 Pin to select the Program 4 INPUT 5 Pin to select the Program 5 INPUT 6 Pin to select the Program 6...
Page 13
SERIAL PRINT: On Connector P3, there is a RS232 pin for serial transmission: P3: PIN 6 = TX, PIN 7 = GND You can print on PC (for example through Hyper Terminal programs) or printer (for example our printer PRNTR1) the results of each screw done. The transmission characteristics are: 9600 (bits per second), 8 (data bits), n (no parity), 1 (bits stop 1).
EXPLODED VIEW SPARE PARTS Position Description Quantity Code Membrane TLS 1 896001 Upper panel TLS 1 896002 Spacer 15mm dest4.8mm 890004/T Connector 12 poli spacing 3,50 – F 890009 Connector F 7 pin spacing 3,50 – F 891030 Screw 3x5 872443 Connector I/O 5 pin spacing 3,50 –...
Page 15
7. No one, whether an agent, servant or employee of KOLVER, is authorized to add to or modify the terms of this limited guarantee in any way. However it’s possible to extend the warranty with an extra cost.
Need help?
Do you have a question about the TLS 1 Series and is the answer not in the manual?
Questions and answers