  • Page 2: Installation

    Installation This appliance must be installed by an authorised person in accordance with this instruction manual AS/NZS 5601.1 – Gas installations (installation and pipe sizing), local gas fitting regulations, local electrical regulations, Building Code of Australia and any other government authority. ! Before operating your new appliance please read A = 3 ×...
  • Page 3: Positioning And Levelling

    The appliance may only be installed in permanently- • If the cooker is installed ventilated rooms, in accordance with current national underneath a wall HOOD legislation. The room in which the appliance is cabinet, there must be installed must be ventilated adequately so as to a minimum distance of Min.
  • Page 4: Electrical Connection

    Levelling Connecting the power supply cable to the mains. If it is necessary to level the Fit a normalized plug to the cable, which appliance, screw the corresponds to the load indicated on the data plate; adjustable feet into the places if the cooker is connected directly to the mains, an provided on each corner of the omnipolar circuit-breaker with a minimum opening of...
  • Page 5: Gas Connection

    ! The manufacturer declines any liability should If a flexible hose is used, it should be as short as these safety measures not be observed. possible with a maximum length of 1.5 metres; Gas connection This appliance is suitable for use with This appliance is suitable for use with This appliance is suitable for use with This appliance is suitable for use with...
  • Page 6: Adapting To Different Types Of Gas

    ! Should the gas pressure used be different (or vary Duplicate Data Plate Where the data plate is obscured by cabinetry when slightly) from the recommended pressure, a suitable the cooker is in the installed position, place a pressure regulator must be fitted to the inlet hose in duplicate data plate on a surface of the cabinetry accordance with current national regulations relating adjacent to the cooker.
  • Page 7: Post Installation Checks

    Post Installation Checks For other minor adjustments or if the appliance does not Perform post installation checks and ensure proper perform correctly: contact Arisit Pty Ltd 1300 762 219 and safe operation before leaving. Test all burners individually and in combination. Leak Check •...
  • Page 8: Technical Specifications

    Gas Inlet Fitting 1/2” BSP (male) thread WS6TMC2CXAUS at rear of cooker Location of gas inlet 185 mm from top of cooker 85 mm from left edge of cooker WIRING DIAGRAM - WS6TMC2CXAUS TECHNICAL DATA Appliance 93x59.5x59.5 cm dimensions (HxWxD) Oven dimensions...