NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems
Hardware User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Spectrum-3 SN4000 1U and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nvidia Spectrum-3 SN4000 1U

  • Page 1 NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 2: Table Of Contents

    Troubleshooting Specifications Specifications Appendixes Appendixes Accessory and Replacement Parts Accessory and Replacement Parts Thermal Threshold Definitions Thermal Threshold Definitions Interface Specifications Interface Specifications Disassembly and Disposal Disassembly and Disposal NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 3 Document Revision History Document Revision History NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 4 1711615283860 Api V2 Figure 9. Image2020 5 8 22 43 4 Version 1 Modificationdate 1711615282603 Api V2 Figure 10. Image2020 5 8 22 42 32 Version 1 Modificationdate 1711615281757 Api V2 NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 5 1711615304350 Api V2 Figure 21. Image2021 10 3 15 19 56 Version 1 Modificationdate 1711615307830 Api V2 Figure 22. Image2019 3 5 17 9 55 Version 1 Modificationdate 1711615323433 Api V2 NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 6 1711615325197 Api V2 Figure 33. Image2019 3 5 17 35 21 Version 1 Modificationdate 1711615326880 Api V2 Figure 34. Image2019 3 5 17 35 41 Version 1 Modificationdate 1711615326603 Api V2 NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 7 1711615325197 Api V2 Figure 41. Image2022 5 31 17 51 49 Version 1 Modificationdate 1656514150203 Api V2 Figure 42. Image2018 11 14 14 50 31 Version 1 Modificationdate 1711615408117 Api V2 NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 8 Relevant for Models: SN4410, SN4600/SN4600C and SN4700 About this Manual This manual describes the installation and basic use of NVIDIA Ethernet switches based on the NVIDIA® Spectrum®-3 ASIC. Ordering Information See Ordering Information. Intended Audience This manual is intended for IT managers and system administrators.
  • Page 9 A list of the changes made to this document are provided in Document Revision History. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 10: Ordering Information

    NVIDIA Spectrum-3 based 400GbE 1U Open Ethernet Switch Last 9N312- 410- with ONIE, 24 QSFP-DD28 and 8 QSFP-DD ports, 2 Power Time 00RB- WS2R Supplies (AC), x86 CPU, standard depth, C2P airflow, Rail Kit NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 11 NVIDIA Spectrum-3 based 100GbE 2U Open Ethernet Last 9N302- 600- Switch with ONIE, 64 QSFP28 ports, 2 Power Supplies (AC), Time 00R7- CS2RO x86 CPU, standard depth, C2P airflow, Rail Kit SN4700 Part Numbers NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 12 NVIDIA Spectrum-3 based 200GbE 2U Open Ethernet Switch 9N302- with ONIE, 64 QSFP56 ports, 2 Power Supplies (AC), x86 (End of VS2RO CPU, standard depth, C2P airflow, Rail Kit Life) NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 13 NVIDIA Spectrum-3 based 400GbE 1U Open Ethernet Switch 9N301- with Onyx, 32 QSFPDD ports, 2 Power Supplies (AC), x86 (End of 00RB- WS2R CPU, standard depth, C2P airflow, Rail Kit Life) NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 14: Introduction

    Introduction The SN4000 series switches are the 4th generation of NVIDIA Spectrum® switches, purpose-built for leaf/spine/super-spine datacenter applications. Allowing maximum flexibility, SN4000 series provides port speeds spanning from 1GbE to 400GbE, and a port density that enables full rack connectivity to any server at any speed. In addition, the uplink ports allow a variety of blocking ratios to suit any application requirement.
  • Page 15 For a full list of all available ordering options, see Ordering Information. SN4410 Front View SN4600 Front View SN4600C Front View SN4600/SN4600C Rear View SN4700 Front View SN4410/SN4700 Rear View NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 16 Front Yes, 2 Yes, 6 SN4600 Front Front Front Yes, 2 Yes, 3 SN4600C Front Front Front Yes, 2 Yes, 3 SN4700 Front Front Front Yes, 2 Yes, 6 NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 17 Certifications For a list of certifications (such as EMC, Safety and others) per system for different regions of the world, please contact your NVIDIA representative. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 18: Installation

    Due to thermal considerations, the switch systems must be installed in a horizontal position. do not install the systems vertically. images/downloa d/thumbnails/2 705813081/ima ge2022-8-24_15- images/download/thumbnails/2705813081/image 46-8-version-1- 2022-8-24_15-48-2-version-1-modificationdate- modificationdat 1711615152657-api-v2.png 1711615154340 -api-v2.png images/downloa images/download/thumbnails/2705813081/image d/thumbnails/2 2022-8-24_15-43-36-version-1-modificationdate- 705813081/ima 1711615155400-api-v2.png ge2022-8-24_15- NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 19 The installation procedure for the system involves the following phases: Procedure Follow the safety warnings Safety Warnings Pay attention to the air flow consideration within the Air Flow system and rack NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 20 Power (rear) side inlet to connector Connector (front) side inlet to power side outlet - marked with blue power side outlet - marked with red power supplies/fans FRUs’ handles. supplies/fans FRUs’ handles. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 21 OPN designation is “-R”. Power side inlet to connector side outlet. Blue latches are placed on the power inlet side. OPN designation is “-F”. Package Contents NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 22 1 x Harness: HAR000631 – Harness RS232 2M cable – DB9 to RJ-45 2 x Cable retainers for each power supply unit Note If anything is damaged or missing, contact your sales representative at Networking-support@nvidia.com. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 23: Sn4600/Sn4600C Fixed Rail Kit

    2x Rack mount ears (C) 8x M6 Standard cage nuts (D) 8x M6 Standard pan-head Phillips screws (E) 4x Flat Head Phillips 100 DEG 6-32X1/4" ST.ST PATCH 360 (F) Rack Rail Kit Parts NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 24 The FRU side is extractable. Mounting the rack brackets inverted to the FRU side (Option 2) will allow you to slide the FRUs, in and out. Short Racks (430-580 mm) Installation Options Rear side (FRUs) Front side (ports) NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 25 Rear side (FRUs) Front side (ports) Short Racks (430-580 mm) Installation - Side View Front side (ports): Rear side (FRUs): Standard Racks (580-800 mm) Installation - Side View Front side (ports): NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 26 2. Secure the chassis in the rails by screwing 2 flat head Phillips screws (F) in the designated points with a torque of 1.5±0.2 Nm. Attaching the Rails to the Chassis NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 27 4. Install 8 cage nuts (D) in the desired 1U slots of the rack: 4 cage nuts in the non- extractable side and 4 cage nuts in the extractable side. Installing the Cage Nuts NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 28 5. Attach the two rack mount blades (B) to the back side (FRU side) of the rack by inserting four M6 screws (E) in the designated cage nuts. Do not tighten the screws yet. Attaching the Brackets to the Rack NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 29 (B) on the rack. Use four M6 screws (E) to fix the rack mount ears (C) to the rack. Do not tighten the screws yet. Sliding the Blades in the Rails Warning NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 30: Sn4410/Sn4700 Fixed Rail Kit

    430-800 mm The following parts are included in the fixed rail kit (see figure below): 2x Rack mount rails (A) 2x Rack mount blades (B) 2x Rack mount ears (C) NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 31 The FRU side is extractable. Mounting the rack brackets inverted to the FRU side (Option 2) will allow you to slide the FRUs, in and out. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 32 In short racks, the system’s ventilation openings should be framed by the designated windows in the rails, as shown below. Short Racks (430-580 mm) Installation - Side View Front side (ports): Rear side (FRUs): NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 33 2. Secure the chassis in the rails by screwing 2 flat head Phillips screws (F) in the designated points with a torque of 1.5±0.2 Nm. Attaching the Rails to the Chassis NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 34 2 flat head Phillips screws (F) in the designated points with a torque of 1.5±0.2 Nm. Attaching the Brackets to the Chassis NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 35 5. Attach the two rack mount blades (B) to the back side (FRU side) of the rack by inserting four M6 screws (E) in the designated cage nuts. Do not tighten the screws yet. Attaching the Brackets to the Rack NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 36 Sliding the Blades in the Rails 7. When fully inserted, fix the switch by tightening the 8 screws (E) inserted in Step 5 and Step 6 with a torque of 4.5±0.5. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 37: Cable Installation

    For a list of Supported Cables and Transceivers, please refer to the SN4000 Systems Datasheet. For full cabling guidelines, ask your NVIDIA representative for a copy of NVIDIA Cable Management Guidelines and FAQs Application Note. For more information about port LEDs, refer to Port LEDs.
  • Page 38 QSFP Cable Orientation Splitter (Breakout) Cables and Adapters When using an NVIDIA splitter cable, the following splitting options are available: SN4410 (see "SN4410 Splitting Options”): Each 100GbE port (ports #1-24) provides up to 24 100GbE NRZ; or up to 48 100GbE NRZ, using a QSFP-DD to QSFP28 splitter cable (1/10/25/40/50GbE speeds are supported as well).
  • Page 39 100GbE, without any limitations. Using Splitter (Breakout) Cables with NVIDIA Onyx (MLNX-OS) When using this feature, you should log into the NVIDIA Onyx (MLNX-OS) CLI and configure the individual ports to be ‘split-2’ or ‘split-4’. For further information on NVIDIA’s cable, visit https://www.nvidia.com/en-us/networking/interconnect/.
  • Page 40 For more details, see Switch Port Attributes sudo systemctl restart switchd in the Cumulus Linux User Guide. Examples of Splitter (Breakout or Fanout) Cables SN4410 Splitting Options SN4600/SN4600C Splitting Options NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 41: Initial Power On

    Warning The system platform will automatically power on when AC power is applied. There is no power system. Check all boards, power supplies, NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 42 LED light is on, make sure that the Fan Status LED shows green.If the Fan Status LED is not green, unplug the power connection and check that the fan module is inserted properly and that the mating NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 43: System Bring-Up

    Il faut de’brancher toutes les alimentations stabilise’es. System Bring-Up For bring-up of a switch system with NVIDIA Onyx (MLNX-OS) operating system installed, see Configuring Network Attributes Using NVIDIA Onyx (MLNX-OS). For bring-up of a switch system with Cumulus Linux operating system installed, see Configuring Network Attributes Using Cumulus Linux.
  • Page 44 Tera Term) on your host PC with the settings described in the table below. Once you perform that, you should get the CLI prompt of the system. Serial Terminal Program Configuration Parameter Setting Baud Rate 115200 Data bits NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 45 None Flow Control None Step 3. Login as admin and use admin as password. On the first login, the NVIDIA Onyx (MLNX-OS) configuration wizard will start. Step 4. To configure network attributes and other initial parameters to the system, follow the configuration wizard as shown in the Configuration Wizard Session table below.
  • Page 46 Mask length may not be zero if address is not zero (interface eth0) Step 5: Netmask? [0.0.0.0] 255.255.255.0 Step 6: Default gateway? [for example 192.168.10.1] 10.10.10.255 Step 7: Primary DNS server? NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 47 Netmask: 255.255.255.0 IPv6 enabled: yes Autoconf enabled: no Autoconf route: yes Autoconf privacy: no DHCPv6 running: no IPv6 addresses: 1 IPv6 address: fe80::202:c9ff:fe63:b55a/64 Speed: 1000Mb/s (auto) Duplex: full (auto) NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 48 Step 6. Check the software version embedded in your system, using the command ‘show version’. Compare this version to the latest version that can be retrieved from NVIDIA support site. To upgrade software, please refer to the NVIDIA Onyx (MLNX-OS) User Manual.
  • Page 49 3. Login as admin (default username is admin, password is admin). 4. Once you get the CLI prompt, you are ready to use the system. For additional information about NVIDIA Onyx (MLNX-OS), refer to the NVIDIA Onyx (MLNX- OS) User Manual located on the NVIDIA Networking Documentation Website.
  • Page 50: Fru Replacements

    For a list of the FRU replacements, see “Accessory and Replacement Parts”. Power Supplies NVIDIA systems that are equipped with two replaceable power supply units work in a redundant configuration. Either unit may be extracted without bringing down the system. Warning Make sure that the power supply unit that you are NOT replacing is showing green for the power supply unit LED.
  • Page 51 *Illustration only. The design may vary in different systems. To insert a power supply unit: 1. Make sure the mating connector of the new unit is free of any dirt and/or obstacles. Warning NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 52 4. Insert the power cord into the supply connector. 5. Insert the other end of the power cord into an outlet of the correct voltage. *Illustration only. The design may vary in different systems. Warning NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 53 40°C ambient temperature, and one of the system fans becomes faulty, it is recommended to replace the fan within 24 hours of failure. To remove a fan unit: Note NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 54 1. Make sure the mating connector of the new unit is free of any dirt and/or obstacles. 2. Insert the fan unit by sliding it into the opening until slight resistance is felt. Continue pressing the fan unit until it seats completely. Warning NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 55 The green Fan Status LED should light. If not, extract the fan unit and reinsert it. After two unsuccessful attempts to install the fan unit, power off the system before attempting any system debug. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 56: Interfaces

    1GbE to 200GbE/400GbE (for more details, see Specifications). To change the port speed configuration, use the command “speed” under interface configuration mode. Refer to the NVIDIA Onyx (MLNX-OS) User Manual for instructions on port speed re-configuration.
  • Page 57 Warning Make sure you use only FCC compliant Ethernet cables. The USB interface is USB 2.0 compliant and can be used by NVIDIA Onyx software to connect to an external disk for software upgrade or file management. The connector complies with the USB 3.0 type A standard.
  • Page 58 Use a flat object to push the reset button. When using an NVIDIA Onyx (MLNX-OS) based system, keeping the reset button pressed for more than 15 seconds will reset the system and the “admin” password, this should allow you to login without a password and set a new password for the “admin”...
  • Page 59: Data Interfaces

    Maximum Speed 400GbE 200GbE 100GbE PAM4 100GbE NRZ SN4410 40GbE 50GbE 25GbE 10GbE 1GbE 200GbE PAM4 100GbE NRZ 40GbE 100GbE PAM4 SN4600 50GbE 25GbE 10GbE 1GbE SN4600C 100GbE 40GbE NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 60 The following table specifies each system's ports max power capabilities: High Power Transceivers Support Model Family Ports Maximum High Power Support 1-24 SN4410 25-32 All ports SN4600 49-50, 53-54, 57-58, 6.5W 61-62 NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 61: Led Notifications

    The LED in the red oval shows the system’s status. Front (Ports Side): *The figure is provided for Illustration purposes only. The design may slightly vary in different systems. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 62 Both of these LEDs in the red ovals show the Front (Ports fans’ status. Side): *The figures are provided for Illustration purposes only. The design may slightly vary in different systems. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 63 Do not insert tools or body parts into the fan module cavity. Power Supply Status LEDs The LED in the red oval shows the power supply status. Front (Ports Side): NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 64 If the problem resumes, refer are not operational or not powered to Troubleshooting for further up/ the power cord is disconnected. instructions. Power Supply Unit Status Rear LED Assignments NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 65 (config) # show leds switch Module LED Status -------------------------------------------------------------------------- MGMT UID Blues To deactivate the UID LED on a switch system, run: (config) # led MGMT uid off switch NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 66 8 indication states. By pressing the button, the next indication state will be selected in a cyclic manner. The current state can be identified by the LED NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 67 Only one of the link types can be up at a given time. 8x/1xF 8x/1xG 8x/1xH The port LED behavior indicates the port state, as follows: SN4410/SN4700 Port LEDs Indications NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 68: Inventory Information

    The system’s inventory parameters (such as serial number, part number and GUID address) can be extracted from the inventory pull-out tab on the lower left side of the rear panel. Pull-out Tab SN4600/SN4600C: NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 69 SN4410/SN4700: NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 70: Software Management

    Info This document is preliminary and subject to change. The system includes an embedded management CPU card that runs NVIDIA Onyx® (MLNX-OS®) management software. This system includes a CLI, WebUI, SNMP, system management software, Ethernet protocols and IB management software (OpenSM).
  • Page 71 Software and firmware updates are available from the NVIDIA Support website. Check that your current revision is the latest one available on the NVIDIA Support website. If you do not have the latest revision, upgrade your software using the CLI or the GUI. Copy the updated software to a known location on a remote server within the user’s LAN.
  • Page 72: Troubleshooting

    Cause: Possible fan issue Solution: Fan Status LED is Amber Check that the fan is fully inserted and nothing blocks the airflow Replace the fan FRU if needed NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 73 Press enter to boot the selected image or 'p' to enter a password to unlock the next set of features. Highlighted entry is 0: " NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 74 System boot Software failure while upgrade failed See Monitoring and Troubleshooting in Cumulus using Cumulus on x86 based Linux User Guide. Linux systems NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 75: Specifications

    Two power cords are provided for each power supply unit in order to meet the electrical requirements of various regions. Please make sure to use the cord that meets the power requirements of your country or region. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 76 CB, cTUVus, CE, CU, S_Mark, FCC, VCCI, ICES, RCM, BSMI, Safety/ EMC: Regulato KCC, CCC RoHS: RoHS compliant Power Input Voltage: SN4600: 1x/2x, 15A/100 Vac, 15A/110Vac, 12A/120Vac, 10A/200- 240Vac, NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 77 1/10/25/40/50/100/200/400GbE per port Connector cage: 32 QSFP-DD Operational: 0° to 35°C Temperature: Non-Operational: -40° to 70°C Environm Operational: 10% - 85% non-condensing ental Humidity: Non-Operational: 10% - 90% non-condensing Altitude: 3050m NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 78 Typical power with passive cables (ATIS): 630W Consumption: CPU: Intel x86 2.20GHz Quad Core PCIe: 4x Gen 3.0 Main Devices Switch: NVIDIA Spectrum®-3 Memory: 16GB RAM , 60GB SSD Throughput 25.6Tb/s NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 79: Appendixes

    1U\2U systems into 4-poles, 430- 0C, SN4410, on Kits 00JN-000 800mm depth racks SN4700 930- MTEF- NVIDIA fan module, 80 x 80 [mm], Modules 9NFAN- SN4600 FANF-I P2C Airflow, For SN4600 switch 00IT-000 NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 80 RS232 Cable - DB9 to RJ45 2M SN4410, HAR00063 harness 2M for SX67X0 and SN4600/SN460 Harnesse SB78X0 0C, SN4700 ACC001449 N/A Power Cord Gray 250V 10A SN4410, 1830MM C14 TO C15 EUR + CCC SN4600/SN460 NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 81: Thermal Threshold Definitions

    For thermal threshold definitions in Cumulus Linux, see Configuring SNMP Traps in the Cumulus User Guide. Interface Specifications Small Form Factors Specifications NVIDIA switch systems come in a flexible range of form factors - SFP/QSFP, SFP28/QSFP28, SFP56/QSFP56 and SFP-DD/QSFP-DD. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 82: Disassembly And Disposal

    In order to connect a host PC to the Console RJ45 port of the system, a RS232 harness cable (DB9 to RJ45) is supplied. RJ45 to DB9 Harness Pinout Disassembly and Disposal Disassembly Procedure NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 83 Dispose of this product and all of its parts in a responsible and environmentally friendly way. Follow the instructions found here for proper disassembly and disposal of the switch, according to the WEEE directive. Lithium Battery NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 84 The battery can explode if not properly used, replaced, or disposed Dispose of the battery according to your local regulations. Do not attempt to recharge the battery, disassemble, puncture, or otherwise damage it. NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 85 Speeds in Specifications Added: January 11, 2021 A note in Specifications regarding the operational temperature of the SN4700 systems October 25, 2020 1.2 Updated: High Power/LR4 Transceivers Support in Interfaces NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...
  • Page 86 Revisi Date Description Global Power Consumption in Specifications October 8, 2020 Updated Accessory and Replacement Parts June 24, 2020 First release © Copyright 2024, NVIDIA. PDF Generated on 06/05/2024 NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual...