Sensor cable
Safety Instructions
The sensor must be considered a LIVE cable; therefore any extension made
to the sensor wiring should be treated in the same way as normal mains
voltage cabling.
The sensor can be extended up to a total of 500 meters using 0,75-1,5 mm2
installation cable.
If temperature wire sensor is applied on conductive surface it must be
installed with additional electrical insulation.
Caution: temperature sensor, heated surface and heating cable could have
really high temperature.
Sensor, conduit, fixing materials, etc. should be specified to be able to
withstand temperatures applied by application.
Caution: Temperature sensor with silicon cable should not be installed in
concrete, aggressive and corrosive environment, etc.