If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
Use carefully. They contain important you may find descriptions of individual information concerning your personal features that do not apply to your safety as well as on use and care of the specific appliance. appliance. This extractor hood complies with all Please retain the operating and relevant safety regulations.
Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or Light Fan settings roasting is taking place, is reduced.
Page 6
filters"). inwards and fold the filters down. 2. Insert the activated carbon filter. At the same time take hold of the under- side of the grease filters with your other hand. 3. Engage the lug.
Cleaning and care Replacing the light bulbs Isolate the extractor hood by pulling out 1. Switch off the extractor hood and pull the mains plug or switching off the fuse. out the mains plug or switch off the electricity supply at the fuse box.
Only one side of the extractor hood Please ask your dealer or inquire at your may be installed next to a high-sided unit local authority about current means of or high wall. Gap at least 50 mm.
flue that is interlocking, etc. currently used for other purposes, nor into a shaft that is used for ventilating rooms in If the air intake is inadequate, there is a which stoves or fireplaces are also located.
Pipe connection Before installing the one-way flap, Screw the ensure that the lettering or stamp is on the enclosed air-pipe outside. connector over the air outlet.
Weight in kg: A separator must be installed in the household circuit. A suitable separator is a Exhaust air Recirculating air switch that has a contact gap of more than 18,5 60 cm 16,5 3 mm and interrupts all poles. Such devi-...
4. Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling. Insert plugs into the holes so that they are flush with the wall.
Page 13
Installation 08. Screw in the two lower hexagon head 11. Remove the protective film from the cap screws. two flue ducts. Before the 4 screws are tightened Take care not to damage the down, align the extractor hood properly. stainless steel surfaces which are susceptible to scratches etc.
Need help?
Do you have a question about the D8642N0GB and is the answer not in the manual?
Questions and answers