NEFF D76M35N0GB Installation Instructions Manual
NEFF D76M35N0GB Installation Instructions Manual

NEFF D76M35N0GB Installation Instructions Manual

How to use and look after your built-in cooker hoods

Advertisement

Quick Links

Installation instructions and
how to use and look after your
built-in cooker hoods
NEFF (UK) Ltd

Advertisement

Table of Contents
loading

Summary of Contents for NEFF D76M35N0GB

  • Page 1 Installation instructions and how to use and look after your built-in cooker hoods NEFF (UK) Ltd...
  • Page 2 Fig. 1 Abb. 1 ELECTRO...
  • Page 3: Table Of Contents

    Table of contents General Information .................... Information on protection of the environment ................Before using the appliance for the first time ..................Safety Instructions ....................Intended use ................................Technical safety ..............................Special information for gas cookers ......................Proper use ................................
  • Page 4: General Information

    Please Before switching on your new appliance, plea- help us by disposing of the packaging in an se read the operating instructions carefully. environmentally friendly manner. They contain important information on safety Packaging parts can be hazardous for children.
  • Page 5: Safety Instructions

    – if they are not physically or mentally and whose exhaust gases are conveyed to the capable of doing so, exterior by a flue. – or if they do not have the knowledge and experience to operate the appliance RISK OF POISONING correctly and safely.
  • Page 6: Special Information For Gas Cookers

    15 minutes at maximum thermal load. Due to the effect of the heat there is a risk of burns if An intake/exhaust air wall box alone does not the surfaces of the housing are touched! ensure compliance with the limit value.
  • Page 7: Proper Use

    Do not flambé under the extractor hood or work with a naked flame. When switched on, the extractor hood draws flames into the filter. There is a risk of fire due to deposits on the grease filter! Do not leave pans, frying pans or deep-fat fryers unattended if you are cooking food with oils or fats, e.g.
  • Page 8: Operating Modes

    The extractor hood can be used in exhaust air and circulating air mode. Appliance dimensions Exhaust air Exhaust-air mode The air which is drawn in is cleaned by the grease filters and conveyed to the exterior by a pipe system. Circulating-air mode...
  • Page 9: Operation

    The description of the operation applies to blower when you start cooking and not to several appliance models. It is possible that switch it off again until several minutes after you individual features are described which do not have finished cooking. In this way the kitchen apply to your appliance.
  • Page 10: Cleaning And Care

    Under normal operation (daily 1 to 2 hours), or a mild window cleaner only. the metal-mesh grease filters must be cleaned – Do not scrape off dried dirt, but moisten with 1x month. a damp cloth..in the dishwasher –...
  • Page 11: Removing And Installing The Grease Filters

    Installing and removing the activated grease filters carbon filters 1. Open the lock and fold down the grease 1. Remove the grease filters (see Removing filters. In doing so, hold the underside of the and installing the metal-mesh grease filters).
  • Page 12: Changing The Bulbs

    Changing the halogen bulbs Halogen bulbs become very hot during operation. Even some time after the appliance has been switched off, there is still a risk of burns! Before changing the halogen bulbs, ensure that they have cooled down fully.
  • Page 13: Installation Instructions

    Attach reducing connector directly to the air- NOTE: If long, rough exhaust air pipes, a lot of pipe connector. pipe bends or pipe diameters less than 150 mm are used, the air capacity will be less...
  • Page 14: Electrical Connections

    – Neutral situations. Brown – Live If you fit your own plug, the colours of these The extractor hood may be connected to a wires may not correspond with the identifying correctly installed earthed socket only. marks on the plug terminals.
  • Page 15: Installation

    Installation The extractor hood is designed to be Installation preparations mounted on the wall. 1. Mark a centre line on the wall from the ceiling to the lower edge of the extractor During installation, optional accessories may hood. also require fitting.
  • Page 16: Attachment

    Locking screws and locking caps 1. Mark the holes for the safety screws. Detach the extractor hood, drill holes for the safety screws and press in wall plugs flush with the wall.
  • Page 17: Installing The Flue Ducts

    Note the position of the slots in the flue duct! – Exhaust-air mode: Slots of the inner flue duct downwards. 5. Screw the inner flue duct with 2 screws to – Circulating-air mode: Slots of the inner flue the sides of the fixing bracket. duct upwards.
  • Page 18 Notes...
  • Page 19 Notes...
  • Page 20 Notes...
  • Page 21 Notes...
  • Page 22 Notes...
  • Page 23 Accessories Z5131X5 Z5132X5 Z5133X5...
  • Page 24 NEFF (UK) Ltd. Grand Union House, Old Wolverton Road, Old Wolverton Milton Keynes, MK12 5PT Tel: 01908 328300 9000 414 351 Fax: 01908 328399 Printed in Germany 0309 Es...

This manual is also suitable for:

D77m35n0gbD79m35n0gb

Table of Contents