Feellife Air Pro User Manual

Portable mesh nebulizer

Advertisement

Air Pro产品说明书
尺寸:120mm*100mm(H)
材质:100g书写纸
工艺:骑马钉-装订成册-单色印刷
User Manual for portable
Mesh Nebulizer
Air P ro
Model No.:
Version:V2
封面

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Air Pro and is the answer not in the manual?

Questions and answers

Виктор
May 28, 2025

Марка небулайзера "air pro _______ "цифра 8 римская.Что это значит?

Subscribe to Our Youtube Channel

Summary of Contents for Feellife Air Pro

  • Page 1 Air Pro产品说明书 尺寸:120mm*100mm(H) 材质:100g书写纸 工艺:骑马钉-装订成册-单色印刷 User Manual for portable Mesh Nebulizer Air P ro Model No.: Version:V2 封面...
  • Page 2: Table Of Contents

    Content 1. Important Safety Notes 2. Product 3. Installation and user Installation 8-10 4. How to use 10-11 5. Cleaing and Disinfection 11-12 6. Storage and Maintenance 12-14 7. Contraindications,Precautions,Notice and Warning 15-16 8. Trouble Shooting Tips After-sales Service 16-20 10.
  • Page 3: Important Safety Notes

    Thank you very much for purchasing Feellife Mesh Nebulizer. Be sure to read this user manual carefully before using the Unit, so that you can use it safely and correctly. Please keep this user manual properly in place for easy reading.
  • Page 4: Product

    1. Product Name: Portable Mesh Nebulizer 2. Model No.: Air Pro 3. Working Principle and Mechanism The portable nebulizer is driven by the rapid oscillation of the circuit, making thepiezoelectric ceramic.The working principle of the portable atomizer is driven by the rapid...
  • Page 5 Temperature:5℃ ~ 40℃ Working Relative Humidity:30% ~ 85% R.H. Environment Atmospheric pressure:86.0 kPa ~ 106.0 kPa Temperature:-10℃~ +50℃ Storage/delivery Relative Humidity:30% ~ 85%R.H. Environment Atmospheric pressure:86.0 kPa ~ 106.0 kPa The median particle size in this nebulizer is measured with 0.9% physiological salineunder conditions of a temperature of 25 ±...
  • Page 6: Installation And User Installation

    • For medical institutions and family for atomization. The atomizer for drug inhalation therapy. Applicable to adults, the elderly breathing, infants and children should be use dunder adult supervision. • The user should also be capable of understanding general operation of Air Pro and the content of user manual. 3.Installation and User Instructions...
  • Page 7 • Do not dismantle or repair the equipment or components, do not dismantle, replace the battery. If you need to replace the battery, please consult or purchase from Feellife Medical Inc.
  • Page 8: How To Use

    4.How to use • Ass liquid to the medication cup 1. Prepare: Cleaning and disinfecting the components and spray connector, medication cup when use. 2. Inject the liquid: open the medication cover and Inject liquid in to the medication cup, then screw the lip ( as the following Figure 1) Note: Follow the doctor's advice to inject the liquid, do not exceed the maximum capacity of the...
  • Page 9 a.Connect the mouthpiece b.Connect the mask Note: Clean, disinfect, dry all parts before installation Hold the nebulizer to keep medication contact with the vibrating mesh, using the following three ways of inhalation according to individual needs. c: By mask a:direct inhalation b: by mouthpiece 3) When finishing nebulization, press ON/OFF switch to power off.
  • Page 10: Cleaing And Disinfection

    4)The nebulizer can set the working time to 10 minutes, and it will shut down automatically after 10 minutes. If you need to continue to use, press the ON / OFF switch. Please make sure there is enough liquid in the medication cup. 5) Use clear water to clean the medication cup, Spray Connector, medication cover, and accessories, and then disinfect.
  • Page 11: Storage And Maintenance

    Note: •Please avoid cleaning the main unit in water in case water entering; •Please keep the main unit and accessories dry and clean for the following safe use; •Please avoid using distilled water or multiple filtering water to start nebuliction. 2.Disinfection medication cup, Spray Connector, medication cover, mask, mouthpiece etc should be disinfected after use.
  • Page 12: Contraindications,Precautions,Notice And Warning

    )Storage instructions: .The device is valid for 5 years in the above mentioned storage condition. b.The nebulizer should be promptly cleaned and disinfected after use, the medication cup and other accessories should store into the packing box after completely drying. Stored in the required environmental condition, avoiding impact 2.
  • Page 13 2. Notice and suggestion The nebulizer is a medical device and is intended for human use only. Please follow the instructions in the manual or under the guidance of a doctor, infants and young children and special care crowd should be used under the supervision of the guardian. Please use original parts and accessories.
  • Page 14 Do not wash the whole unit with running water to avoid water come inside the device, especially the USB connector. Do not use the microwave ovens to dry or disinfect the unit, or may cause fire. Please place it in a place where children, infants and psychotic patients can not reach it. Please use qualified manufacturers of lithium battery power charger(output5.0V/1.0A).
  • Page 15: Trouble Shooting Tips

    Volatile oil are not allowed, may cause damage to module. Water-soluble medication and saline dilutions medication are allowed to nebulization,or may cause bronchospasm. Oily medication are not allowed. The device is not workable for respiration anesthesia system and respirator system. Do not spill liquid to the device to avoid leakage, the possibility of electric shock and cause malfunction, failure to use.
  • Page 16: After-Sales Service

    1) Please choose the babies mask to cover mouth and nose for better effect. 2) Please choose kids mask to cover mouth and nose for better Special care for babies effect. and childrens Note:Children and babies should be helped and watched by a adult when using the device.keep it away from the children when no use.
  • Page 17 IP22 Separate collection for Refer to instruction General No toxic and Anti-exposure manual/ booklet NOTE electrical and Waterproof Grade imperative harmful substances and elements On ME EQUIPMENT electronic equipment Note, Warning The application Avoid The Representative Upward Fragile refer to part of Type BF Moisture of European Union...
  • Page 18 RF emissions Class B CISPR 11 Harmonic emissions This device is suitable for use in all establishments, including Class A IEC 61000-3-2 domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings Voltage fluctuations/ used for domestic purposes.
  • Page 19 Power frequency Power frequency magnetic fields should be at leve (50/60 Hz) 3A/m 3A/m ls characteristic of a typical location in a typical magnetic field commercial or hospital environment. IEC 61000-4-8 Portable and mobile RF communications equipment should be used no closer to any part of this device, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
  • Page 20 Precautions 1) In order to regulate the requirements for EMC with the aim to prevent unsafe product situations,the EN60601-1-2 standard has been umplemented. The nebulizer Air Pro conforms to the EN60601-1-2:2007 standard for both immunity and emissions. 2) Portable and mobile RF communication equipment may affect the performance of the nebulizer, avoid strong electromagnetic interference when using, such as close to mobile phones, microwave ovens and so on.
  • Page 21: Warranty Card

    Serial Serial No.: No.: @feellife Email:info .com Serial Serial No.: No.: @feellife Email:info .com...
  • Page 22: Certificate Of Inspection

    CERTIFICATE OF INSPECTION Feellife Medical Inc Product:Portable mesh nebulizer Model:Air Pro Inspection date: Inspector:...
  • Page 23: Configuration List

    Configuration list If Included Item Quantity Unit Medication cup Adult mask Child mask Mouthpiece User manual Warranty card Certificate of inspection User Guidance Velvet bag Micro USB cable Warning badge Warning board...
  • Page 24 Manufacturer Information Manufacturer: FEELLIFE MEDICAL INC. Manufacturer Address: Room 1903, Building A, No.9 Furong Road, Tantou Community, Songgang Subdistrict, Bao' an District, Shenzhen 518104 Guangdong, China. Tel:+0086-755-2699 3192 After-sales service:FEELLIFE MEDICAL INC. Service life: 5 years Website: http://www.feellife.com Prolinx GmbH...

Table of Contents