Basic Settings Tab - Omron SENSOR SUPPORT SOFTWARE S3 Operation Manual

Table of Contents

Advertisement

Display window for new sensor settings New settings of E3NT-L
8-2-2-3-2
Output mode
8-2-3

Basic settings tab

46
The output circuit is set in the Output mode box. The output circuit can be set
jointly for both outputs:
• PNP, plus-switching, open collector
• NPN, minus-switching, open collector
• Complementary, push-pull, plus/minus-switching (factory default setting)
The sensor is set by default to the push-pull output (complementary). In this
output setting, both output transistors are alternately active.
When the output circuit is set to PNP or NPN, the relevant output circuit that is
currently not in use is switched off.
Both output circuits are resistant to short-circuits and are polarity-safe.
The general parameters of the selected sensor are set in the Basic settings
menu.