CX-Process Monitor Plus Specifications
CX-Process Monitor Plus Specifications
Item
Product name
Model
Applicable PLC-series
Applicable Unit
Personal computer
Applicable computer
CPU
OS
Memory
Hard disk drive
Monitor
CD-ROM drive
Mouse
Printer
Sound board
Software that must be installed at the same time
Connection with CPU
Connecting method
Unit (or Serial
Communications
Board/Unit)
Connection via Controller Link
Connection via Ethernet
Loop Control Unit/Board data specification method
Offline operation functions
User
Online
Configuration
operation
functions
Screen
6
CX-Process Monitor Plus
WS02-LCMC1-EV2
CS/CJ-series
•Loop Control Unit Ver. 2.0 or higher
•Loop Control Board
•Process-control CPU Unit
•Loop-control CPU Unit
IBM PC/AT or compatible
Min. required: Pentium MMX233 MHz or faster, Recommended: Celeron 400 MHz or faster
Microsoft Windows NT 4.0 (Service Pack 6a or higher), Windows 2000 Professional (Service Pack 4 or higher),
Windows XP Professional (Operation is not supported on Windows 95, 98, or ME.)
Min. required: 128 Mbytes, Recommended: 256 Mbytes or more
Min. required: 650 Mbytes of free space, Recommended: 800 Mbytes or more of free space
Min. required: XGA, Recommended: XGA or higher, min. 1024 x 768 dots, 256 colors
At least one
Recommended: Microsoft mouse or compatible pointing device
Any printer supported by Microsoft Windows
1 board
FinsGateway (One of the following must be installed according to the communications method with the PLC.)
•Serial Unit driver (Host Link)
•Controller Link driver (Controller Link)
•CLK (PCI) driver (Controller Link, PCI bus)
•ETN_UNIT driver (Ethernet)
Using FinsGateway
Serial Unit version
Using FinsGateway
CLK (PCI) Driver
Using FinsGateway
Controller Link
driver
Using FinsGateway
ETN_UNIT driver
CSV tags and tags for Monitor Plus (CSV monitor tags) are set using the CX-Process Tool.
These tags are used to specify Loop Control Unit/Board data.
Prepare user configuration screens for use in the online operation screen.
Overview Screen
Place buttons for progressing on the Control Screen, Trend Screen, and other screens. Four columns and
eight lines are displayed on each screen (32 screens max.). Alarm status for each loop is displayed on
the button on Control Screens.
Control Screen
Control blocks such as the PID blocks and Indication blocks, and some Operation blocks are displayed for up
to 8 loops in a single screen in the form of a field device. The maximum number of screens is 400.
This screen displays the SP, PV, and MV numeric values, displays a PV as a bar graph that can be scaled,
and can be used for changing the SP, MAN, and other setting values. When an alarm occurs, the color of the
bar graphs changes. You can progress to the Tuning Screen from the Control Screen.
Tuning Screen
This screen is for setting P, I, and D parameters in control blocks such as the PID blocks. The PV, SP, and MV
can be monitored while tuning the parameters. The maximum number of screens is 400 x 8 = 3,200.
When an alarm occurs, the color of the bar graphs changes.
Fine-tuning according to the degree specified by the user is possible for PID constants.
Trend Screen
The analog signals output from tag ITEMs for each function block can be collected at fixed intervals and
saved to a file. If necessary, up to 8 analog signals can be displayed on one screen in the form of
a multi-dot recorder.
Data collected
(logger function)
Data display
Descriptions
Connect the computer to the CPU Unit's peripheral port, RS-232C port,
or the RS-232C port of a Serial Communications Unit.
•Connecting Cable:
When connecting to the CPU Unit peripheral ports: Model CS1W-CN
When connecting to the CPU Unit's RS-232C port: Model XW2Z-
For details on the Connecting Cables, refer to CX-Process Monitor Plus Operation
Manual (Cat. No. W428).
•Communications protocol with PLC: Host Link (not supported on Peripheral bus)
Install the driver in a computer equipped with a Controller Link Support Board
(PCI slot) to support communications between the computer and PLCs equipped
with a Controller Link Unit.
Install the driver in a computer equipped with a Controller Link Support Board
(ISA slot) to support communications between the computer and PLCs equipped
with a Controller Link Unit.
Install the FinsGateway ETN_UNIT driver on the computer on which an Ethernet
board is mounted to enable communications with the PLC on which the Ethernet
Unit is mounted.
Stores 10, 20, 50, 100, or 300
Realtime trend
hours of data for up to 480
tags sampled at 1, 2, 5, 10, or
30-second intervals.
Historical trend
Stores 30, 150, 300, 900, or
1,800 days of data for up to
960 tags sampled at 1, 5, 10,
30, or 60-minute intervals.
Horizontal (time) axis: 2, 4, 8, 12 and 24-hour time units can be scrolled
Vertical (8-point common) axis: Graduation can be enlarged by a factor or 1, 2, 5 and 10.
Data is displayed from the time when the specified display start time is reached.
Display color: Red, yellow, green, blue, magenta, purple, cyan, or white
(2 m, 6 m)
-
(2 m, 5 m)
Data can be saved in CSV format
either using button commands,
or automatically at a set interval
(every 1, 2, 3, 4, 6, 8, 10, 12, 18,
20, 24, 48, 72, 96, 120, or 240
hours).