  • Page 1 SELF-CLEANING DESKTOP IONIZING AIR BLOWER AP - M001 Shanghai Anping Static Technology Co.,Ltd SELF-CLEANING DESKTOP IONIZING AIR BLOWER A P & T...
  • Page 2 Suitable for electronics, optoelectronics, semiconductor and other industries Effectively solve the problems caused by static electricity Static removal Prevent adhesion of objects Prevent material splash Prevent static electricity Prevent blockage of feeder Speciality Creates Value...
  • Page 3 High Efficiency Static Removal Keep a cl ea n p ro du ctio n e n v i ron m e n t an d sta y away f ro m stati c e l e ctr i ci t y 600mm 900mm 1200mm...
  • Page 4 Features Safe / Easy to use / Durable ▍ Automatic needle brushing ▍ Standard tungsten alloy needle Automatic needle brushing when start up. By default, the needle is automatically brushed Longer life time compare to titanium and every 24 hours for manual cleaning and main- silicon materials.
  • Page 5: Product Specifications

    Product Specifications Product Details / Product Parameter / Product Size ◈ Product appearance Metal mesh cover ABS screw handle (M6×12) U-shape bracket Air volume adjustment knob Power switch Power socket Working status indicator light ◈ Product Dimension Unit:mm ⑥ ⑤ ⑦...
  • Page 6 Product Specifications Product Details / Product Parameter / Product Size ◈ Product parameter Model AP-M001 Input voltage DC15V Power Working voltage ±DC4000-DC7000V Ion emission Steady-state DC Emitter electrode Tungsten Alloy Discharge structure Uncoupled electrical contact (discharge cylinder) Discharge range 750*300mm(L*W)...
  • Page 7: Use Of The Product

    Use of the product Installation Step / Installation Position / Packaging Accessories ◈ Installation step ◈ Installation Position Place the ionizing air blower in the work area where static electricity is to be eliminated and the installation angle is perpendicular to the surface of the charged body. 300~750mm 300~750mm Take out the power adapter from the packing box and...
  • Page 8: Troubleshooting

    Safety warning Please read the instruction manual carefully before installing and using this equipment. The whole set of equipment must be reliably grounded during use, and the connection resistance of the electrical connection to the AC equipment ground should be less than 1 ohm. Do not use this equipment in environment where humidity is >...
  • Page 9 It can be used only after the electrical performance index is normal. After-sales service AP-M001 ionizing air blower has undergone rigorous testing and aging treatment before ex-work. Its performance has completely reached the relevant indicators marked in the usage instruction.
  • Page 10 SPECIALITY CREATES VALUE Professional electrostatic intelligent monitoring/analysis and elimination solution provider RS485 通讯 Shanghai Anping Static Technology Co.,Ltd Tel:021-6451 7676 Website:www.ap-static.com Address:3-4/F,Building 27,No.69,Guiqing Road,Shanghai,China...

This manual is also suitable for:

Ap-dc2451-001Ap-dc2451