Pondmaster ProLine PUV-4000 Care And Operating Instructions

Low pressure filter system

Advertisement

For Your Information:
POnDfflASTER
LOW PRESSURE FILTER SYSTEM
FEATURES
--+---- L
A
-
Quick Connect Hose Fitting
- For easy tool-free hose
removal and reassembly.
B
-
Clear Multiport Valve
- Control and visually monitor
water clarity during backwash/rinse operation.
C
-
Waste Port Valve
- Convenient ball valve directs waste
water.
D
-
UV Lamp
(PUV Models only) - Internal long thin bulb
assembly forces water close to bulb for longer contact time
with rays. Can be added to all models.
E
-
Bio-Matrix Media
- Reusable media affords maximum
surface area for beneficial bacterial growth.
F -
Agitator
- Efficiently unlocks waste from media with
minimum water loss during backwash/rinse.
G
-
Optional Bottom Valve
(Not Shown) - Available and
recommended to facilitate seasonal draining.
H
-
UV Lamp Ballast
(PUV Models only) - Top mount for
convenient access. Can be added to all models.
I -
Agitator Handle
- Dual purpose - Manually turns internal
agitator; also allows safe monitoring of UV Lamp status.
J -
Pressure Gauge
- Displays internal pressure to indicate
when routine backwash is necessary.
K
-
Stainless Steel Clamp
- Stainless steel security with Hex
Locknut.
L -
Heavy Duty Poly Canister
- Weather proof - - designed
for burial near pond.
Each piece of Bio-Matrix Media has
2.25 square inches of surface area
available for beneficial bacterial colonization.
Basic Setup Guide
®
PUV-4000, PUV-2000, PUV-1000- Biological, Mechanical and Ultraviolet Filtration
P - 4000, P - 2000, P - 1000 - Biological and Mechanical Filtration (UV Clarifier not included)
TOWASTE
AREA
@
BOTTOM DRA IN•
Simplifies winter Maintenance; drains water from the bottom.
@
Uses ultraviolet light to inhibit algae from reproducing.
ULTRAVIOLET CL A RIFIER•
©
PRO BIOLOGICAL FILTER AND FALLS•
@
Keeps debris away from intake. Skims, protects pump.
PRO SKIMMER•
©
CHECK VALVE•
Best installed between pump and filter.
(E)
VALVED BYPA SS
(Not Shown)• Split water flow between filter and a waterfall.
To set up the filter you will need to supply the following items.
f)
- - 1112" Flexible hose (recommended)
Hoses
GATHER
Stainless Steel Hose Clamps
MATERI AL S
Plumber's Teflon tape
In-Line Check Valve
1
112"
insert
MPT by BARB
OTHER SUPPLIES MAY BE NECESSARY FOR OPTIONS AND ACCESSORIES CHOSEN.
IJ
This filter must be connected to an external water pump.The water pump can be
submersible or above ground depending on your preference. Pondmaster makes
CHOOSE
several perfectly matched pumps and accessories to complete your filter system.
LOCATION
Please note the following:
and
• The intake for the water pump should be positioned at the opposite end of the
DETAILS
pond from the water return.
• The filter drum must be buried up to an inch below the pressure clamp. If
positioned above ground use the backfill from digging the pond.
TYPICAL INSTALL ATION
-"
BACK-FILL SOIL AND
LANDSCAPE R
PRESSURIZED
BOTTOM
BOTTOM DRAIN
N
INSTALLED
���
BURIED
TO WASTE/ DRY WELL
FROM PUMP
DANNER MFG. INC.• Islandia, New York 11749
Visit our web site at www.Dannermf g .com
See Additional instructions for important details
II
©
-N-
CHECKVALVE
g
----- final mounted position. Installation details of the UV Clarifier are included.
ATTACH QU ICK CONNECTS AND
Produces a dramatic waterfall effect.
WASTE VALVE
-- for connections to pump and filter drain
[m
�==:;;;;;;; � ....::_: :...:..: ::.:_
adapter
for waste valve
FILTER
OPTIONAL
PRO
1 I The
SKIMMER OPTIONAL
OPTIONAL
be in the
J ERFALL
SUBMERSIBLE
2)
Turn the
����:
U � , N
PUMP
the
3) Turn on the pump and check
the hoses and clamps.
[
a
U
POND
The Baseline number will vary based on your
particular setup; it should not exceed 5 PSI. The
�ts�
II II I I I
I II II II
PSI should continue to read close to the Baseline
until debris starts to accumulate in the filter. Do no
backwash until pressure rises 2 - 3 PSI over original baseline.
Your Pressurized Filter System works best within a certain range
C H OOSE
IMPORTANT
of flow and pressure. Exceeding these values will cause leakage
INFORMATION!
PUMP
or breakage of filter or its components.
PRESSURIZED FILTER
MAXIMUM PUMP
MAXIMUM BA SELINE
CAPACITY (GAL/HR)
PRESSURE (P.S.1.)
P1000 or PUV1000
2000
P2000 or PUV2000
2000
P4000 or PUV4000
4000
NOTE: If the pump you would like to use exceeds these values, use a Valved Bypass.
Unpack the Main filter unit. It is completely factory assembled and pressure tested. Do not
SET UP
open the cover. If your filter includes the UV Clarifier, place it aside until after the filter is in its
H OSES
ATTACH HOSES
WASTE
VALVE
OUT TO
WASTE
TEST
Before turning on pump, set valves as shown in the FILTER SETTINGS illustration.
SETUP
O ther settings will be used for maintenance.
WASTE
PORT VALVE
BACKWASH
IN
CLOSED
SETTINGS
/ POSITION
CLEAR
ULTIPORT
VE DURING
RMAL
Waste Port Valve
should
1 I The
Waste Port Valve
should be
position.
CLO SED
in the
OPEN
position.
Multiport Valve
to
Turn the
2)
Multiport Valve
FILTER
position.
BACKWASH
position.
3) Agitate the filter media by moving
the agitator handle back and forth.
]
The Pressure Gauge provides
G A U GE
a reading immediately once
filter is set up and running.
NOTE: PRESSURE SHOULD NOT BUILD BEYOND 8 PSI. IF IT DOES,
BACKWASH IMMEDIATELY TO PREVENT DAMAGE TO THE FILTER.
..
,, .., .., .., .., .., .., .., .., ..,
"
4'
DO NOT OPEN FI L TER!
,
It is completely assembled and
-
pressure tested at the factory
., .., .., .., .., .., .., .., .., ..,
tlllf
-
� See Section 9 of main instructions ,­
"'-
FOR POND SIZED
(GALLONS)
s
UP to 1000
5
UPto 2000
5
A bove2000
or WATERFALL
WASTE PORT
VALVE
RINSE
IN
OPEN
SETTINGS
/ POSITION
With
open
1)
Waste Port Valve
turn main valve to
RINSE
position.
to the
Turn the agitator handle left to
2)
right until water clears up.
3)
Turn the
Multiport knob
back
to the
position and close
FILTER
the
Waste Port Valve
to resume
filtering. Check Gauge weekly.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProLine PUV-4000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pondmaster ProLine PUV-4000

  • Page 1 / POSITION This filter must be connected to an external water pump.The water pump can be assembly forces water close to bulb for longer contact time submersible or above ground depending on your preference. Pondmaster makes CHOOSE CLEAR with rays. Can be added to all models.
  • Page 2 LOW PRESSURE FILTER SYSTEM CARE AND OPERATING INSTRUCTIONS MODELS UPC# PUV-4000 05045 PUV-2000 05025 PUV-1000 05015 P- 4000 05040 P-2000 05020 P-1000 05010...
  • Page 3: Before You Begin

    DNA. Please note that UV light does not kill algae that cling to the sides of ponds. If your pond has string algae you can add Pond master Pond Fix with activated barley to inhibit growth of floating Algae and Pondmaster Oxy Scrub to remove algae from rock surfaces. BEFORE YOU BEGIN: •...
  • Page 4: Electrical Precautions

    FEATURES - For easy tool-free A - Quick Connect Valve Fitting hose removal and reassembly. � -- ® - Control and visually B - Clear Multiport Valve ® monitor water clarity during backwash/rinse operation. - Convenient ball valve directs C - Waste Port Valve waste water away from pond during rinse or backwash.
  • Page 5 @ BO T TOM D RA IN ( ITEM#1501 0) Pondmaster Pressurized Filters can be fitted with an optional bottom drain. Not to be confused with the backwash/rinse valve and hose used for weekly maintenance, the bottom drain is used to simplify annual winter maintenance by draining water from the bottom of the filter drum directly, without having to remove the water through the top - - either by siphoning or using a wet vac with a thin extension tube.
  • Page 6 This filter must be connected to an external water pump. The water pump can be submersible or above ground depending on your preference. Pondmaster makes several perfectly matched powerful pumps and accessories to complete your filter system. Please note the following: •...
  • Page 7 IMPORTANT INFORMATION! PUMP CHOOSING THE CORRECT PUMP Your Pressurized Filter System works best within a certain range of flow and pressure. See Table below. Exceeding these values will cause leakage or breakage of the filter or its components and void the warranty. PRESSURIZED FILTER MAX PUMP OUTPUT MAXIMUM BASELINE FOR POND SIZED...
  • Page 8 FILTER OPERATING INSTRUCTIONS VERY IMPORTANT INFORMATION ON HOW TO USE THIS FILTER. Unlike other filters, this filter works best when the media is "dirty". untouched in order to After initial setup the filter must be allowed to run 3 to 4 weeks grow the bacterial colonies on the filter media that will biologically filter the water.
  • Page 9 WINTERIZATION ....WHERENECESSARY CAUTION: During harsh winters, water left in the drum may freeze, expand and crack the drum. necessary, the filter can be drained and winterized at the end of the season. If you live in an area that doesn't experience freezing temperatures, you may never need to do this.
  • Page 10: Disassembly And Reassembly

    **IMPORTANT** DISASSEMBLY and REASSEMBLY DISASSEMBLY: REMOVE BALLAST, It should never be necessary to open the cover and --- BULB disassemble the filter. Regular backwash and rinse maintenance will control the bacterial colonies inside the filter drum; bulb replacement of the UV Clarifier requires QUARTZ SLEEVE unscrewing the ballast from the top without removing the cover.
  • Page 11 CARE AND OPERATING INSTRUCTIONS FOR UV CLARIFIER WARNING! TURN OFF THE POWER BEFORE HANDLING OR SERVICING THE UNIT. DANGER! NEVER LOOK DIRECTLY AT THE LAMP RAYS. T he UV lamp and quartz sleeve are not installed and are located in separate boxes inside the main carton. Note that a When handling the UV lamp, do not touch the glass micro-switch...
  • Page 12: Troubleshooting

    TROUBLESHOOTING General Note: Avoid opening filter cover. Most problems can be corrected without accessing the interior of the filter. " PROBLEM POSSIBLE CAUSE SOLUTION Filter output is Media needs backwashing. Backwash filter. See section 7. sluggish. Pump intake is clogged. Check pump and clear debris.
  • Page 13: Parts And Accessories

    15075 Small Drum (25) # 05015 13" height PUV-1000 WARRANTY # 05025 Pondmaster Filtration systems are warranted against failure due PUV-2000 to defects in materials and/or workmanship for one year from # 05045 15070 Large Drum (25) 19" height date of purchase.This warranty covers defects occurring under...

Table of Contents