Summary of Contents for Eaton TRIPP-LITE N600H-0288-6

  • Page 1 Fiber Splice Horizontal Models: Closure N600H-0288-6 Este manual está disponible en español en la página de Eaton: Tripplite.Eaton.com/support Ce manuel est disponible en français sur le site Web de Eaton : Tripplite.Eaton.com/support 04-066-9347C1-EN.indd 1 04-066-9347C1-EN.indd 1 1/2/2024 10:08:46 AM 1/2/2024 10:08:46 AM...
  • Page 2 1. Closure Assembly 1.1 Open the Closure Using a flat-head tool, pry open the buckles of the closure (Figure 1-1). Figure 1-1: Open the buckle of the closure 1.2 Install the Uncut Cable Turn around the limiting button to turn over all the splicing trays from the bottom (Figure 1-2).
  • Page 3 1. Closure Assembly Remove the nut component from the pass-through cable entry (Figure 1-3). Note: The cable entry is suitable for uncut cable or branching cable. Figure 1-3: Put down the nut component Loosen the two screws of the nut component, then open the nut component (Figure 1-4).
  • Page 4 1. Closure Assembly Loosen the four screws of the wedge (Figure 1-5). Figure 1-5: Put down the wedge Cut open the circular sealing ring in a horizontal direction (Figure 1-6). Figure 1-6: Cut open the sealing ring 04-066-9347C1-EN.indd 4 04-066-9347C1-EN.indd 4 1/2/2024 10:08:50 AM 1/2/2024 10:08:50 AM...
  • Page 5 1. Closure Assembly Loosen the two screws to remove the upper press clamping (Figure 1-7). Figure 1-7: Remove the upper clamping Remove the upper and lower linings if using a cable with a larger diameter (Figure 1-8). Figure 1-8: Remove upper and lower hinge for large diameter cable 04-066-9347C1-EN.indd 5 04-066-9347C1-EN.indd 5 1/2/2024 10:08:53 AM...
  • Page 6 1. Closure Assembly Strip the sheath of the uncut cable for a suitable length ≥4 ft. (1.2 m) (Figure 1-9). Bare fiber protecting sleeve Bare fiber Bare fiber loose tube Cable sheath Figure 1-9: Strip the uncut cable Cut the strength member of the cable from the stripped cable sheath to 2.4 in.
  • Page 7 1. Closure Assembly Run the cable through the hole: Insert the strength member, then secure the strength member with the screw (Figure 1-11). Note: To enhance cable surface friction, use sandpaper. Description Sandpaper Quantity 1 Pc. Figure 1-11: Secure the strength member 04-066-9347C1-EN.indd 7 04-066-9347C1-EN.indd 7 1/2/2024 10:08:54 AM...
  • Page 8 1. Closure Assembly Secure the upper press clamping (Figure 1-12). Figure 1-12: Secure the upper press clamping Secure the wedge (Figure 1-13). Figure 1-13: Secure the wedge 04-066-9347C1-EN.indd 8 04-066-9347C1-EN.indd 8 1/2/2024 10:08:56 AM 1/2/2024 10:08:56 AM...
  • Page 9 1. Closure Assembly Store the loose tube in the bottom case (Figure 1-14). Figure 1-14: Store the loose tube Manage cable with the magic band tie (Figure 1-15). Figure 1-15: Manage cable with magic band tie 04-066-9347C1-EN.indd 9 04-066-9347C1-EN.indd 9 1/2/2024 10:08:57 AM 1/2/2024 10:08:57 AM...
  • Page 10 1. Closure Assembly Install the pass-through cable on the other side (Figure 1-16). Figure 1-16: Install the pass-through cable on the other side 04-066-9347C1-EN.indd 10 04-066-9347C1-EN.indd 10 1/2/2024 10:08:57 AM 1/2/2024 10:08:57 AM...
  • Page 11 1. Closure Assembly Using a pair of scissors or other cutting tool, cut a small hole into the grommet (Figure 1-17). Note: To enhance cable entry sealing, apply silicon oil into the grommet. Scissors optional, not included in accessories list. Description Silicon Oil Quantity...
  • Page 12 1. Closure Assembly Note: If using Ø14-Ø18.7 single grommet, a washer should be added to both sides. Description 13 Washer Quantity 8 Pcs. Description 16 Washer Quantity 8 Pcs. Description 19 Washer Quantity 8 Pcs. Figure 1-17: Cut small hole into grommet Run the pass-through cable through the single hole grommet, squeeze component, and nut component (Figure 1-18).
  • Page 13 1. Closure Assembly Install the screws of the nut component and fasten the screws (Figure 1-19). Figure 1-19: Fasten the screws Push and screw all the components for the pass-through cable inward (Figure 1-20). Figure 1-20: Install all the components 04-066-9347C1-EN.indd 13 04-066-9347C1-EN.indd 13 1/2/2024 10:08:59 AM...
  • Page 14 1. Closure Assembly For the unused pass-through cable hole, use a single-hole grommet to seal the cable entry (Figure 1-21). Note: If a single-hole grommet does not provide a seal, a choke plug should be inserted into this hole. Choke Plug Description (Ø12.5 mm) Quantity...
  • Page 15 1. Closure Assembly 1.3 Install the Branching Cable Turn over the splice tray and remove the nut for the branching cable from the cable hole (Figure 1-22). Note: The cable entry is only suitable for branching cable. Figure 1-22: Remove the nut Loosen the two screws to remove the upper press clamping (Figure 1-23).
  • Page 16 1. Closure Assembly Strip the branching cable to a suitable length of ≥4 ft. (1.2 m) (Figure 1-24). Bare fiber Bare fiber protective sleeve Figure 1-24: Strip the branching cable Cut the strength member of the cable from the stripped cable sheath 2.4 in. (60 mm) to fix the cable (Figure 1-25).
  • Page 17 1. Closure Assembly Attach the branching cable into the hole: insert the strength member, then secure the strength member with the screw (Figure 1-26). Figure 1-26: Attach the strength member Secure the upper press clamping (Figure 1-27). Note: When bare fiber cable is used, an EVA tube should be applied to protect the bare fiber and insulation tape should be used to wrap the EVA tube and cable.
  • Page 18 1. Closure Assembly Store and manage the cable (as shown in steps 17 and 18 in section 1.2 Install the Uncut Cable), then push and screw all the components for the branching cable inward (Figure 1-28). Figure 1-28: Push all the components For the unused branching cable hole, loosen the nut, then insert the sealing plug, squeeze component and the nut.
  • Page 19 1. Closure Assembly 1.4 Splice and Store the Fiber Cut the loose tube with a loose tube stripper. Pull out the loose tube, then clean the bare fiber with cleaning paper (Figure 1-30) Description Cleaning Paper Quantity 1 Pc. Figure 1-30: Strip the fiber 04-066-9347C1-EN.indd 19 04-066-9347C1-EN.indd 19 1/2/2024 10:09:03 AM...
  • Page 20 1. Closure Assembly Insert the bare fiber into the EVA tube, then secure the EVA tube and fiber in the splice tray with a tie (Figure 1-31). Description Nylon Cable Tie 20 Pcs. Quantity (use as required) Description EVA Tube Quantity 1 Roll Figure 1-31: Secure the EVA tube and fiber...
  • Page 21 1. Closure Assembly Coil the bare fiber in the splicing tray (Figure 1-32). Single Splicing Description Protective Tube Quantity 288 Pcs. Figure 1-32: Coil the bare fiber 04-066-9347C1-EN.indd 21 04-066-9347C1-EN.indd 21 1/2/2024 10:09:03 AM 1/2/2024 10:09:03 AM...
  • Page 22 1. Closure Assembly Close the cover of the splicing tray and tie them up with the bondage belt (Figure 1-33). Figure 1-33: Close the splicing tray cover 04-066-9347C1-EN.indd 22 04-066-9347C1-EN.indd 22 1/2/2024 10:09:04 AM 1/2/2024 10:09:04 AM...
  • Page 23 1. Closure Assembly 1.5 Close the Closure Put the cover on the bottom case. Take note of the direction of the cover. Close the buckles that connect the cover and the bottom case according to the sequence shown in Figure 1-34. Figure 1-34: Close the buckles 04-066-9347C1-EN.indd 23 04-066-9347C1-EN.indd 23...
  • Page 24 2. Closure Installation 2.1 Aerial Installation (Default Installation Configuration) The aerial installation accessory is shown in Figure 2-1. Description Aerial Mounting Hardware Quantity 1 Set Figure 2-1: Aerial installation accessory Fix the aerial clasps into the slots at the edge of the bottom base (Figure 2-2). Figure 2-2: Install the clasps 04-066-9347C1-EN.indd 24 04-066-9347C1-EN.indd 24...
  • Page 25 2. Closure Installation Mount the closure to the wire and fasten the bolts (Figure 2-3). Figure 2-3: Mount the closure to the wire 04-066-9347C1-EN.indd 25 04-066-9347C1-EN.indd 25 1/2/2024 10:09:09 AM 1/2/2024 10:09:09 AM...
  • Page 26 2. Closure Installation 2.2 Wall Installation (Optional) The wall-mounting accessory is shown in Figure 2-4. Figure 2-4: Wall-mounting accessory Drill two holes in the wall using a percussion drill (Figure 2-5). Wall Figure 2-5: Drill holes in the wall 04-066-9347C1-EN.indd 26 04-066-9347C1-EN.indd 26 1/2/2024 10:09:09 AM 1/2/2024 10:09:09 AM...
  • Page 27 2. Closure Installation Position the two holes 14 in. (360 mm) apart (Figure 2-6). Unit: mm Figure 2-6: Position of the holes Hammer the expansion bolt completely into the drilled holes. Rotate the bolt clockwise to make the expansion sleeve wholly expanded, then rotate the nut counterclockwise and remove the spring washer, flat washer and nut (Figure 2-7).
  • Page 28 2. Closure Installation Fix the wall-mounted clasps into the slots at the edge of the bottom base (Figure 2-8). Figure 2-8: Install the clasps Put the closure with the wall-mounted clasps onto the wall (Figure 2-9). Figure 2-9: Put the closure onto wall 04-066-9347C1-EN.indd 28 04-066-9347C1-EN.indd 28 1/2/2024 10:09:10 AM...
  • Page 29: Warranty

    (3) years from the date of initial purchase. Our obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. Visit Tripplite.Eaton.com/ support/product-returns before sending any equipment back for repair. This warranty does not apply to equipment which has been damaged by accident, negligence or misapplication or has been altered or modified in any way.
  • Page 30 04-066-9347C1-EN.indd 30 04-066-9347C1-EN.indd 30 1/2/2024 10:09:10 AM 1/2/2024 10:09:10 AM...
  • Page 31 04-066-9347C1-EN.indd 31 04-066-9347C1-EN.indd 31 1/2/2024 10:09:10 AM 1/2/2024 10:09:10 AM...
  • Page 32 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com © 2023 Eaton Eaton is a registered All Rights Reserved trademark. Publication No. 23-04-066 / 93-47C1_RevA All trademarks are property May 2023 of their respective owners. 04-066-9347C1-EN.indd 32 04-066-9347C1-EN.indd 32...