Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this
product must be performed by a qualified electrician. This product must be installed in accordance
with the applicable installation code by a person familiar with the construction and operation of the
product and hazards involved.
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting
any maintenance. Disconnect power at fuse or circuit breaker.
Risk of Fire- Refer to product label for specific minimum supply conductor requirements.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly.
Failure to comply with these instructions may result in death, serious bodily injury and property damage.
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind
that may arise from the improper, careless, or negligent installation, handling or use of this product.
NOTICE: Green ground wire provided in proper location. Do not relocate.
ATTENTION Receiving Department: Note actual fixture description of any shortage or noticeable damage on
delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be
filed within 15 days of delivery. All damaged material, complete with original packing must be retained.
Safety: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and
ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under
installation section.
APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area
of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to
installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation
and insertion of photo control or shorting cap (if so equipped). Best results will be obtained if installed and
maintained according to the following recommendations.
WARNING
WARNING
Brand Logo
reversed out of
Lumark AP
black
INS #
INS #

Advertisement

loading
Need help?

Need help?

Do you have a question about the Lumark AP CLCS and is the answer not in the manual?

Questions and answers

Summary of Contents for Cooper Lighting Solutions Lumark AP CLCS

  • Page 1 Failure to comply with these instructions may result in death, serious bodily injury and property damage. DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling or use of this product.
  • Page 2 Apply weatherproof silicone sealant around all edges between the fixture housing and mounting surface. Cooper Lighting Solutions IB514103EN Installation Instructions...
  • Page 3 If selectable lumen fixture, follow instructions above and set wattage switch to dimming setting at highest wattage. ote: Do not remove the bottom lens or touch the LED optics. All LEDs are preinstalled and ready to operate. Cooper Lighting Solutions IB514103EN Installation instructions...
  • Page 4 La désobéissance aux instructions suivantes représente un risque de blessures graves ou mortelles et de dommages matériels. EXONÉRATION DE RESPONSABILITÉ : Cooper Lighting Solutions n’assume aucune responsabilité pour les dommages ou pertes de toute nature pouvant découler d’une installation inappropriée, imprudente ou négligente et d’une mauvaise manipulation ou utilisation de ce produit.
  • Page 5 être placés correcteent et toutes les vis insérées et serrées fermeent. Appliquez de la silicone étanche sur tous les bords entre le boîtier du luminaire et la surface de montage. Cooper Lighting Solutions IB514103EN Instructions d’installations...
  • Page 6 à la puis sance la plus élevée. Remarque: Ne retirez pas la lentille inférieure, ni ne touchez les optiques DEL. Toutes les optiques DEL sont préintallées et prêtes àl’emploi. Cooper Lighting Solutions IB514103EN Instructions d’installation...
  • Page 7 El incumplimiento de estas instrucciones puede ocasionar la muerte, lesiones corporales graves y daños a la propiedad. RENUNCIA DE RESPONSABILIDAD: Cooper Lighting Solutions no asume ninguna responsabilidad por daños o pérdidas de ningún tipo que puedan surgir por la instalación, manipulación o uso inadecuado, descuidado o negligente de este producto.
  • Page 8 Aplique sellador de silicona impermeable alrededor de todos los bordes entre el alojamiento de la luminaria y la superficie de montaje. Cooper Lighting Solutions IB514103EN Instrucciones de instalación...
  • Page 9 No quite la lente inferior ni toque la óptica LED. Todos los LED se instalaron previamente y están listos para funcionar. Cooper Lighting Solutions IB514103EN Instrucciones de instalación...
  • Page 10 Garantías y Limitación de Responsabilidad Visite www.cooperlighting.com/LightingWarrantyTerms para conocer nuestros términos y condiciones. Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 Cooper Lighting Solutions is a www.cooperlighting.com registered trademark. All trademarks are property Canada Sales of their respective owners.