Download Print this page

Simx Lighting ECOSPOT ELITE LHT1219 BLACK Installation Instructions

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS
ECOSPOT ELITE
TWIN 2x8W LED SPOTLIGHT
PIR Sensor Model: LHT1219 BLACK
Non-PIR Model: LHT1223 BLACK
SINGLE 9W LED SPOTLIGHT
PIR Sensor Model: LHT1221 BLACK
Non-PIR Model: LHT1225 BLACK
Thank you for purchasing the Simx Lighting EcoSpot Elite LED spotlight.
This product is suitable for exterior wall mount locations. It requires a 230V AC power supply to operate and should be
installed by a registered electrician. Please read this manual before installation and retain for future reference.
TECHNICAL SPECIFICATIONS
Power Source
Max. Rated Load
Max. Inrush Current
PIR Detection
PIR Detection Range (approx)
Time ON Adjustment
Max. PIR Switching
Manual Override
IP Rating
Spotlight Adjustment
Lumens
by Colour Temp
CRI
Safety
Mounting
Construction
Operating Temperature
Warranty
PIR Sensor
220-240V AC
Single Models: 9W
Twin Models: 16W (2x8W)
<30A
120°
10m
10 sec - 12 min
50W (PF>0.9)
OFF/ON (>1.5 sec)
IP55
Pan left and right 50°
Tilt down and up 45°
3000K
550 lm per Lamp (1100 lm)
4000K
650 lm per Lamp (1300 lm)
6500K
600 lm per Lamp (1200 lm)
-10°C to + 40°C
Non-PIR
-
-
-
-
-
-
IP65
>90
Class I
Wall
Cast Alloy
3 years
DIMENSIONS (mm)
Twin Spotlight
100
140
102
Single Spotlight
135
110
Pan/Tilt
45º
50º
157
90
50º

Advertisement

loading
Need help?

Need help?

Do you have a question about the ECOSPOT ELITE LHT1219 BLACK and is the answer not in the manual?

Questions and answers

Summary of Contents for Simx Lighting ECOSPOT ELITE LHT1219 BLACK

  • Page 1 PIR Sensor Model: LHT1221 BLACK Non-PIR Model: LHT1225 BLACK Thank you for purchasing the Simx Lighting EcoSpot Elite LED spotlight. This product is suitable for exterior wall mount locations. It requires a 230V AC power supply to operate and should be installed by a registered electrician.
  • Page 2 SIMX LIGHTING • ECOSPOT ELITE SPOTLIGHT INSTALLATION MANUAL IMPORTANT This product is suitable for use only with a supply voltage of 220-240V AC 50Hz. All electrical work must be carried out in accordance with local and national electrical codes as applicable.
  • Page 3 SIMX LIGHTING • ECOSPOT ELITE SPOTLIGHT INSTALLATION MANUAL INSTALLATION • Reattach and screw securely the cover to the base. Ensure cables are not pinched in closing the unit. • Reconnect mains power. • Test circuit and setup PIR settings (see CALIBRATION section).
  • Page 4 SIMX LIGHTING • ECOSPOT ELITE SPOTLIGHT INSTALLATION MANUAL Setting up the sensor (refer to Fig. 3) If the lights are required to operate from dusk, wait for the desired light level, then slowly turn the Lux control knob towards daylight while someone walks across the centre of the detection area.

This manual is also suitable for:

Ecospot elite lht1223 blackEcospot elite lht1221 blackEcospot elite lht1225 black