Sennheiser EW 500 Manual page 80

Evolutionwireless 500 series
Hide thumbs Also See for EW 500:
Table of Contents

Advertisement

Available languages

Available languages

PHAnto
Switching the phantom powering on/off (SKP 500 only)
The SKP 500 transmitter can supply condenser microphones with 48 V
phantom powering (P 48). Please note: Dynamic microphones can be operated
in phantom powering mode without harm. However, if no condenser
microphone module is being used, you should switch off the phantom
powering. With the phantom powering switched on, the operating time of
the battery will be reduced to approx. 5 hours.
The phantom powering can be switched on or off via the operating menu:
Select the "PHAnto" menu by pressing the
appears on the display; after a short pause the current setting is
displayed.
Press the
button to switch the phantom powering on – if you press
the
button, the phantom powering is switched off. The new setting
– i.e. "ON" or "OFF" – starts flashing on the display.
Press the
SET
button to return to the top menu level. The display
then switches back to the standard display.
SET
button until "PHAnto"
77