Panasonic SF4D-TM1 User Manual
Panasonic SF4D-TM1 User Manual

Panasonic SF4D-TM1 User Manual

Communication module for the sf4d series
Hide thumbs Also See for SF4D-TM1:
Table of Contents

Advertisement

Quick Links

Need technical support for the SF4D communication module?
Contact Ramco Innovations today!
Call our toll free number or email us at nsales@ramcoi.com
WUME-SF4DTM1-4
Ramco Innovations
2018.9
www.PanasonicSensors.com
Communication Module for the
SF4D Series
SF4D-TM1
User's Manual
(800) 280-6933

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SF4D-TM1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Panasonic SF4D-TM1

  • Page 1 Need technical support for the SF4D communication module? Contact Ramco Innovations today! Call our toll free number or email us at nsales@ramcoi.com Communication Module for the SF4D Series SF4D-TM1 User’s Manual 2018.9 WUME-SF4DTM1-4 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 2 (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 3 Thank you for purchasing an SF4D-TM1 communication module for the SF4D series. Before using this product, read and understand this User's Manual and the manual for the light curtain. Use the product correctly and in the optimum manner. Keep this manual in a convenient place for quick reference.
  • Page 4: Table Of Contents

    4-13 Exiting the software tool ····························································· 40 ······································· 41 4-15 Muting function ········································································ 42 4-15-1 Timing settings ·····································································42 ··························································43 4-16 Blanking function ······································································ 44 4-17 Interlock / external device monitor function ···································· 45 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 5 5-7-3 Indication linked to interlock ······················································83 5-7-4 Indication linked to test function ·················································83 5-7-5 Interrupt display function ··························································83 5-7-6 Synchronization method and application indication ························84 ·························84 5-8 Operation monitor function ··························································· 85 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 6 5-9-3 Locking the initialization function ················································86 5-9-4 Locking writing of settings from a PC ··········································86 ············ 87 5-11 Initialization function ·································································· 88 ································································89 ············································91 ············································································ 92 7-2 Dimensions ··············································································· 93 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 7: Chapter 1 Introduction

    Chapter 1 Introduction 1-1 Safety Cautions ···········································································8 1-2 Contents of Package ·································································· 10 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 8: Safety Cautions

    The machine de- Expert engineer as work is performed. Operator In the event that the device does not operate correctly, the operator should immediately © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 9 Do not wire in parallel with a high-voltage line or power line, or run through the same con- duit. Risk of malfunctioning due to induction. Maintenance Other matters © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 10: Contents Of Package

    1-2 Contents of Package Main unit: 1 pc. Quick Instruction Manual (Japanese, English, Chinese) 1 pc. for each language General Information for Safety, Compliance, and Instructions (23 languages) 1 pc. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 11: Chapter 2 Before Using The Device

    2-3-3 Connecting to a PC ·································································17 2-3-4 Disconnecting from the light curtain ············································18 2-3-5 Connecting to the light curtain and PC ········································19 2-3-6 Disconnecting from the light curtain and PC ·································20 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 12: Features

    This function writes settings saved in the device to a light curtain. Saved data initialization function This function initializes the settings and log data that are saved in the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com...
  • Page 13 To change the overall settings of the © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com...
  • Page 14: Description Of Parts

    Lights up when the WRITE key is pressed. Blinks during WRITE communica- WRITE indicator (Orange) tion. 10 ERROR indicator (Yellow) Lights up when an error occurs. For connection to the light curtain. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 15: Connections

    2-3-1 Connecting to the light curtain Step 1: Turn OFF the light curtain power and remove the indicator cover. Light curtain Indicator cover Connector Step 4: The device starts. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 16: Disconnecting From The Light Curtain

    Step 1: Turn OFF the light curtain power. Step 2: All indicators on the device turn OFF. tain. Step 4: Attach the indicator cover to the light curtain. CAUTION fore attaching to the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 17: Connecting To A

    Connections 2-3-3 Connecting to a PC (Purchase separately) Device Step 2: The device starts. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 18: Disconnecting From The Light Curtain

    Connections 2-3-4 Disconnecting from the light curtain Step 2: All indicators on the device turn OFF. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 19: Connecting To The Light Curtain And

    2-3-5 Connecting to the light curtain and PC Step 1: Turn OFF the light curtain power and remove the indicator cover. Light curtain Indicator cover Connector (Purchase separately) Device Step 4: The device starts. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 20: Disconnecting From The Light Curtain And

    Step 1: Turn OFF the light curtain power. Step 2: Step 4: All indicators on the device turn OFF. Step 5: Attach the indicator cover to the light curtain. CAUTION © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 21: Chapter 3 Procedures For Operation

    3-1 Procedures for operating the device ··············································· 22 3-2 Copy functions ·········································································· 23 3-2-1 Copy functions: READ function ·················································23 3-2-2 Copy functions: WRITE function ················································24 3-2-3 Saved data initialization function ················································25 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 22: Procedures For Operating The Device

    When using the device as a standalone unit, you can copy functions set in the light curtain and initialize the device. Description of parts Power indicator (Green) ERROR indicator (Yellow) Data indicator (Orange) WRITE indicator (Orange) READ indicator (Orange) WRITE key READ key © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 23: Copy Functions

    The READ indicator (orange) turns OFF and the data indicator (or- ange) lights up. The settings and log data in the connected light curtain are copied to the device. inside the light curtain. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 24: Copy Functions: Write Function

    The control output (OSSD 1 / 2) of the light curtain turns OFF. The WRITE indicator (orange) turns OFF. The settings saved in the device are written to the light curtain. inside the light curtain. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 25: Saved Data Initialization Function

    The READ indicator (orange) and WRITE indicator (orange) light The data indicator (orange) turns OFF. The settings and logs saved in the device are erased and initialized. inside the light curtain. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 26 Procedures for Operation (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 27: Chapter 4 Software Tool

    4-18-1 How to set the application indicator function ·······························46 4-18-2 How to set the interrupt display function ····································47 ··············································· 48 4-20 Input / output wire setting function ················································ 49 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 28 The software tool is only for use with the device. Enter "SF4D-TM1 2. USB cable Length 3m or less USB A type (male) - USB mini-B type (5 pins, male) © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 29: System Requirements

    Follow the instructions in the installation program to install the software tool. continue the installation. 4-4 Uninstallation Select "Start" - "Control Panel" - "Programs and Functions" to uninstall. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 30: Connection And Disconnection Procedures

    PC and to the light curtain. Device connection destination Power indicator (green) Light curtain Blinking Connected Connected Connected Connected CAUTION permanently to the light curtain. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 31: Starting And Exiting The Software Tool

    Read data from communication module: Refer to "4-10 Reading data from the communi- cation module" Operation monitor: Refer to "4-11 Monitoring light curtain operation" Refer to " " © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 32 3. Select the type. 5. Copy the settings of the currently selected channel to all other channels. 7. Cancel the settings and return to the start screen. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 33 Software Tool Check the contents. To return to the start screen, click "Cancel". © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 34 Software Tool © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 35: Reading Data From The Light Curtain

    To ensure safety, turn OFF the control output (OSSD 1 / 2) while data is read from the light cur- tain. If OFF, the next screen will appear. Check the contents. To return to the start screen, click "Cancel". © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 36 Software Tool © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 37: Reading Data From The Communication Module

    The following screen will appear. Check the contents. To return to the start screen, click "Cancel". © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 38 Software Tool © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 39: Monitoring Light Curtain Operation

    4. The input / output state appears. turns OFF. 6. Return to the start screen. The screen color changes in response to the light reception state of the light curtain. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 40: Exiting The Software Tool

    Open as explained in " ". 4-13 Exiting the software tool Method 1 Select "Exit" from " Method 2 Click " " in the upper right corner of the screen. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 41 Software Tool " at the right 2. Click “ tings. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 42: Muting Function

    Select the muting sensor input order. Select a muting sensor. Run a muting demonstration. Click " " to start. Initialize the settings. For function details, refer to "5-3 Muting function (12-core cable)". © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 43 Software Tool 4-15-2 Each beam axis setting ure settings individually for each channel. 6. Initialize the settings. For function details, refer to "5-3 Muting function (12-core cable)". © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 44: Blanking Function

    Software Tool 4-16 Blanking function screen appears. screen. 6. Initialize the settings. For function details, refer to "5-4 Blanking function". © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 45: Interlock / External Device Monitor Function

    4. To use the external device monitor, set the external device delay time. 5. Initialize the settings. For function details, refer to "5-5 Interlock Function" and "5-6 External device monitor setting (8-core cable, 12-core cable)". © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 46: Application Indicator Function And Interrupt Display Function

    4-18-1 How to set the application indicator function lection is restricted in some cases.) Step 4 Select "Lights" or "Blinking" for application indicator input 1 and application indicator in- put 2. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 47: How To Set The Interrupt Display Function

    4-18-2 How to set the interrupt display function (Selection is restricted in some cases.) Step 3 Select "Lights" or "Blinking" for muting and override. For function details, refer to "5-7 Application Indicator Function". © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 48 3. Select the type. 5. Copy the settings of the currently selected channel to all other channels. 7. Cancel the settings and return to the start screen. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 49: Input / Output Wire Setting Function

    3. The "line synchronization" or "optical synchronization" type automatically appears. not have function assignments. not have function assignments. For function details, refer to "5-1 Input / output wire settings" and "5-2 Input / output speci- ". © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 50 Software Tool (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 51: Chapter 5 Functions

    5-7-2 Indication linked to control output (OSSD 1 / 2) ·····························83 5-7-3 Indication linked to interlock ······················································83 5-7-4 Indication linked to test function ·················································83 5-7-5 Interrupt display function ··························································83 5-7-6 Synchronization method and application indication ························84 ·························84 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 52 5-9-2 Locking the read function ·························································86 5-9-3 Locking the initialization function ················································86 5-9-4 Locking writing of settings from a PC ··········································86 ············ 87 5-11 Initialization function ·································································· 88 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 53 To change the overall settings of the © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com...
  • Page 54: Input / Output Wire Settings

    Selecting the synchronization method for the combination of cable and input / output Synchronization method Line synchronization Line synchronization Optical synchronization Optical synchronization Optical synchronization Line synchronization Optical synchronization Optical synchronization Optical synchronization © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 55 In addition, the test input information to the light curtain emitter is not shared with the receiver, output of the receiver will also prevent operation. When test input is valid, the light curtain emitter © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com...
  • Page 56 OFF when light reception is reception is OFF during muting muting OFF when light is received is received OFF when locked out locked out © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 57 (Black) Control output 1 (OSSD 1) (White) Control output 2 (OSSD 2) (Blue) 0V (Pink) Muting input A (Yellow) Muting input B (Red) Auxiliary output 2 *Symbols Switch S1 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 58 (Pink) Muting input A (Yellow) Muting input B (Red) Auxiliary output 2 *Symbols Switch S1 0 to +2.5V (sink current 5mA or less): Emission halt, Open: Emission © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 59 Terminal Lead wire When "Parallel interference prevention color is selected Emitter Application indicator input 2 Parallel interference prevention input Receiver Auxiliary output 2 Parallel interference prevention output © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 60 OFF when light reception is reception is OFF during muting muting OFF when light is received is received OFF when locked out locked out © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 61 (Black) Control output 1 (OSSD 1) (White) Control output 2 (OSSD 2) (Blue) 0V (Pink) Muting input A (Yellow) Muting input B (Red) Parallel interference prevention output (Gray) not used © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 62 (White) Control output 2 (OSSD 2) (Pale purple) External device monitor input (Blue) 0V (Pink) Muting input A (Yellow) Muting input B (Red) Parallel interference prevention output © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 63 OSSD positive logic OFF when test input is valid input is valid OFF when light re- OFF when light is received is received OFF when locked out locked out © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 64 (Red) Auxiliary output 2 *Symbols Switch S1 Test / reset input (emitter) Switch S2 Test / reset input (receiver), application indicator input 1 / 2, interlock setting input © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 65 Switch S2 Test / reset input (receiver), application indicator input 1 / 2, interlock setting input 0 to +2.5V (source current 5mA or less): Valid, Open: Invalid © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 66 Invalid light re- light re- Valid Invalid Lockout operation put 1 setting ception ception OFF when test input is valid input is valid OFF when locked out locked out © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 67 Test / reset input (emitter) Switch S2 Test / reset input (receiver), application indicator input 1 / 2, muting input A / B Switch S3 Override input © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 68 Invalid light re- light re- Valid Invalid Lockout operation put 1 setting ception ception OFF when test input is valid input is valid OFF when locked out locked out © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 69 Test / reset input (receiver), application indicator input 1 / 2, muting input A / B 0 to +2.5V (source current 5mA or less): Valid, Open: Invalid Switch S5 Override input 0 to +2.5V (source current 5mA or less): Invalid, Open: Valid © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 70 OSSD negative logic OSSD positive logic OFF when test input is valid is valid OFF when light OFF when light is received received OFF when locked © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 71 (Pale purple) External device monitor input (Brown) + V (Black) Control output 1 (OSSD 1) (White) Control output 2 (OSSD 2) (Blue) 0V *Symbols K1, K2: Safety relay unit, etc. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 72 (Blue) 0V (Brown) + V (Black) Control output 1 (OSSD 1) (White) Control output 2 (OSSD 2) 24V DC (Blue) 0V *Symbols K1, K2: Safety relay unit, etc. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 73 (Black) Control output 1 (OSSD 1) (White) Control output 2 (OSSD 2) (Blue) 0V *Symbols Switch S1 Test input Switch S2 Application indicator input 1 K1, K2: Safety relay unit, etc. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 74 0 to +2.5V (source current 5mA or less): Emission halt, Open: Emission Switch S2 Application indicator input 1 0 to +2.5V (source current 5mA or less): Valid, Open: Invalid K1, K2: Safety relay unit, etc. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 75: Muting Input A / B Wire And Override Function

    Parallel interference prevention Line synchronization Incorporated Valid Optical synchronization / standard Optical synchronization Optical synchronization / muting Optical Incorporated Valid synchronization Optical synchronization / muting Optical Incorporated Valid synchronization © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 76: Muting Mode

    The input times of inputs A and B are from a minimum of 0.03, and 0.1 to 59.9 sec., and a The factory settings are 0 sec. for the minimum value and 3 sec. for the maximum value. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com...
  • Page 77: Muting Maximum Continuous Valid Time

    The continuous time is 1 to 600 sec. (increments of 1 sec.). 5-3-9 Each beam axis setting invalid, the control output (OSSD1 / 2) turns OFF and the muting state is canceled. axes. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 78: Blanking Function

    Initialization setting WARNING Before countermeasure Emitter Receiver Danger zone After countermeasure Emitter Receiver Protective structure CAUTION amount (green) remains OFF regardless of the intensity of light received. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 79: Floating Blanking Function

    : Response time of device (sec) SF4D C=8 × (d-14) <Minimum sensing object> Settings SF4D-F ø14mm ø24mm ø34mm ø44mm SF4D-H ø25mm ø45mm ø65mm ø85mm SF4D-A ø45mm ø85mm ø125mm ø165mm © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 80: Interlock Function

    Interlock setting input Manual reset wire setting Incorporated / valid Incorporated / valid Incorporated / invalid Incorporated / valid © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 81: Interlock Mode

    Set the maximum allowed response time for an external device connected to the light curtain. The factory setting is 300ms. If the set allowed delay time is exceeded, the light curtain lockout state activates. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com...
  • Page 82: Application Indicator Function

    2) In the case of optical synchronization, indication only takes place on the light curtain emitter. 3) The light curtain emitter and receiver are each equipped with application indicator input 1. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com...
  • Page 83: Indication Linked To Control Output (Ossd 1 / 2)

    (pink). 5-7-5 Interrupt display function cation of that state, regardless of whether the current application indicator state is , or Lockout Muting Override © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 84: Synchronization Method And Application Indication

    (OSSD 1 / 2) Interlock Test Lockout Muting Override Application indicator input, control output (OSSD 1 / 2), interlock, and test are exclusive selec- ture of the selected colors. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 85: Operation Monitor Function

    Test / Reset input Override input Application indicator input 1 Application indicator input 2 Maintenance mode Auxiliary output 1 (emitter) Auxiliary output 2 (receiver) Muting auxiliary output (emitter) © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 86: Protection Functions

    5-9-4 Locking writing of settings from a PC This stops the setting change function of the device's PC to prevent unintended changes to de- read from and written to the light curtain. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com...
  • Page 87 Manage the password carefully to ensure that you do not forget it. In the event that you forget the password, contact us. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 88: Initialization Function

    To change over- © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com...
  • Page 89 Chapter 6 Troubleshooting © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 90 When using optical synchronization, data was only written to either the emitter and the receiver. emitter or the receiver. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 91 ············································································ 92 7-2 Dimensions ··············································································· 93 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 92 Communication method PC (computer): USB Protective structure IP40 (IEC) 30 to 85% RH, Storage: 30 to 95% RH Elevation Connection method Weight (main unit only) Approx. 75g © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 93: Dimensions

    Dimensions 7-2 Dimensions (Units: mm) 20.4 (0.6) 15.4 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 94 Revision History First edition January 10, 2017 Second edition March 24, 2017 © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933...
  • Page 95 (e) which are operated continuously each day for 24 hours; and which otherwise require a high level of safety performance similar to that required in those equipment, 5. EXPORT CONTROL LAWS © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com...
  • Page 96 Overseas Sales Division (Head Office): 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591 panasonic.net/id/pidsx/global For sales network, please visit our website. © Panasonic Industrial Devices SUNX Co., Ltd. 2018 Ramco Innovations www.PanasonicSensors.com (800) 280-6933 September, 2018 PRINTED IN JAPAN...

Table of Contents