INSTRUCTIONS
MODELS AVX-D-PS,
AVX-D-2-PS, AVX-D-3-PS
LOW JITTER
ANALOG
DELAY GENERATORS
SERIAL NUMBER: ____________
E L E C T R O S Y S T E M S
W A V E F O R M
E L E C T R O N I C S
S I N C E
1 9 7 5
L T D .
BOX 5120, LCD MERIVALE
X
OTTAWA, ONTARIO
CANADA
K2C 3H4
TEL: (613) 226-5772
FAX: (613) 226-2802

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AVX-D-PS and is the answer not in the manual?

Questions and answers

Summary of Contents for Avtech AVX-D-PS

  • Page 1 BOX 5120, LCD MERIVALE OGDENSBURG, NY FAX: 1-800-561-1970 OTTAWA, ONTARIO U.S.A. 13669-0265 CANADA K2C 3H4 TEL: (315) 472-5270 e-mail: info@avtechpulse.com TEL: (613) 226-5772 FAX: (613) 226-2802 http://www.avtechpulse.com/ FAX: (613) 226-2802 INSTRUCTIONS MODELS AVX-D-PS, AVX-D-2-PS, AVX-D-3-PS LOW JITTER ANALOG DELAY GENERATORS SERIAL NUMBER: ____________...
  • Page 2: Warranty

    Avtech product is found to be defective, Avtech shall at its option repair or replace said defective item. This warranty does not apply to units which have been dissembled, modified or subjected to conditions exceeding the applicable specifications or ratings.
  • Page 3: Table Of Contents

    GENERAL INFORMATION................... 13 BASIC TIMING CONTROL.....................13 "-ED" OPTION........................13 MECHANICAL INFORMATION..................14 TOP COVER REMOVAL......................14 ELECTROMAGNETIC INTERFERENCE................14 MAINTENANCE......................14 REGULAR MAINTENANCE....................14 CLEANING..........................14 PERFORMANCE CHECKSHEET................. 15 Manual Reference: T:\instructword\avx-d\AVX-D,all_PS_models,edition4.sxw. Last modified February 6, 2004. Copyright © 2004 Avtech Electrosystems Ltd, All Rights Reserved.
  • Page 4: Introduction

    The three models in the AVX-D analog delay generator series feature low-jitter variable delays in the ranges of 30 ns to 150 ns (Model AVX-D-PS), 30 ns to 10 us (Model AVX- D-2-PS), and 1 us to 100 us (Model AVX-D-3-PS). Model AVX-D-PS offers a very low jitter of ±...
  • Page 5: Specifications

    SPECIFICATIONS Model: AVX-D-PS AVX-D-2-PS AVX-D-3-PS Delay range 30 ns to 10 us 1 us to 100 us 30 ns to 150 ns (3-position (2-position range range switch) switch) Jitter (Ext trig in to ± 30 ps to ± 10 ps ±...
  • Page 6: Ec Declaration Of Conformity

    EC DECLARATION OF CONFORMITY Avtech Electrosystems Ltd. P.O. Box 5120, LCD Merivale Ottawa, Ontario Canada K2C 3H4 declare that this pulse generator meets the intent of Directive 89/336/EEC for Electromagnetic Compatibility. Compliance pertains to the following specifications as listed in the official Journal of the European Communities:...
  • Page 7: Installation

    INSTALLATION VISUAL CHECK After unpacking the instrument mainframe and the transformer module, examine to ensure that they have not been damaged in shipment. Visually inspect all connectors, knobs, and handles. Confirm that a power cord and an instrumentation manual (this manual), are with the instrument.
  • Page 8: Fuses

    FUSES This instrument contains four fuses. All are accessible from the rear-panel. Two protect the AC prime power input, and two protect the internal DC power supplies. The locations of the fuses on the rear panel are shown in the figure below: FUSES #1 AND #2 FUSE #4 FUSE #3...
  • Page 9: Dc Fuse Replacement

    DC FUSE REPLACEMENT The DC fuses may be replaced by inserting the tip of a flat-head screwdriver into the fuse holder slot, and rotating the slot counter-clockwise. The fuse and its carrier will then pop out. FUSE RATINGS The following table lists the required fuses: Nominal Manufacturer’s Distributor’s...
  • Page 10: Front Panel Controls

    FRONT PANEL CONTROLS 1. POWER Switch . This is the main power switch. When turning the instrument on, there may be a delay of several seconds before the instrument appears to respond. 2. OVERLOAD Indicator . When the instrument is powered, this indicator is normally green, indicating normal operation.
  • Page 11 systems using SMA connectors, the PE6026 SMA feed-thru 50 Ohm terminator is suggested. 4. TRIG Connector. A replica of the IN pulse appears on this output. This TTL-level output will drive loads of 50Ω or greater. The output pulse width is approximately equal to the input pulse width.
  • Page 12: Rear Panel Controls

    REAR PANEL CONTROLS DELAY 1.AC POWER INPUT . An IEC-320 C14 three-pronged recessed male socket is provided on the back panel for AC power connection to the instrument. One end of the detachable power cord that is supplied with the instrument plugs into this socket. 2.AC FUSE DRAWER .
  • Page 13: General Information

    GENERAL INFORMATION BASIC TIMING CONTROL This instrument has one pulse input and two pulse outputs. The TRIG output is delayed by a fixed amount (< 20 ns) relative to the IN pulse. The output pulse width is approximately equal to the input pulse width. The OUT output is delayed relative to the input pulses on the IN connector by a time set by the DELAY controls.
  • Page 14: Mechanical Information

    Always disconnect the power cord before opening the instrument. There are no user-adjustable internal circuits. For repairs other than fuse replacement, please contact Avtech (info@avtechpulse.com) to arrange for the instrument to be returned to the factory for repair. Caution: High voltages are present inside the instrument during normal operation.