Page 2
XR17V35x MPIO Tool User Manual Revision History Revision History Document No. Release Date Change Description 030UMR00 March 15, 2024 Initial release. MaxLinear Confidential March 15, 2024 030UMR00...
(MPIOs) for general usage. Each pin can be an input or output function via programming the device configuration registers. MaxLinear provides a Windows MPIO test tool for testing or debug usage. This user manual provides guidance to features and usage of this tool.
Connects or disconnects to the designated COM port. Note that when connecting, this tool checks whether the COM port is a XR17V35x device. If the Device ID is not a standard MaxLinear PCIe UART device number, the check and connection fail.
MPIO Read via Direction Change Connect to the XR17V35x COM port. If connected successfully, the button text changes from Connect to Disconnect as shown in the following figure. Figure 3: MPIO Read via Direction—Connect COM Port MaxLinear Confidential March 15, 2024 030UMR00...
Then, the direction button automatically changes to Input. The latest status when the MPIO4 changes as an input is displayed on the High/Low button as shown in the following figure. Figure 5: MPIO Read via Direction—Latest Status Display MaxLinear Confidential March 15, 2024 030UMR00...
In the MPIO4 as example (which is configured as an input in this case), click on the Read button as shown in Figure It makes the actual read for the corresponding input MPIO (in this case it is MPIO4). Figure 7: MPIO Read via Read—Do Read MaxLinear Confidential March 15, 2024 030UMR00...
XR17V35x MPIO Tool User Manual MPIO Read The latest status is displayed on the High/Low button as shown in the following figure. Figure 8: MPIO Read via Read—Read MPIO Status MaxLinear Confidential March 15, 2024 030UMR00...
In the MPIO4 as example (it is already an output), click on the High/Low button to select the intended state to be written. For example, select the High checkbox as shown in the following figure. Figure 10: MPIO Write—Set State to Write MaxLinear Confidential March 15, 2024 030UMR00...
XR17V35x MPIO Tool User Manual MPIO Write Click on the Write button to do the actual write configuration as shown in the following figure. Figure 11: MPIO Write—Do Write MaxLinear Confidential March 15, 2024 030UMR00...
Set the file name for the intended log file as shown as item 2 in Figure Click Save button as shown as item 3 in Figure 13 Once done, you can find the saved configuration file under the expected folder. Figure 13: Save Config—Save to File MaxLinear Confidential March 15, 2024 030UMR00...
Select the file name of the target log file as shown as item 2 in Figure Click Open button to do the actual load as shown as item 3 in Figure 16 Figure 16: Load Config—Load from File MaxLinear Confidential March 15, 2024 030UMR00...
If the file loaded is valid, the configuration is automatically applied and updated. In the example shown in Figure 17, the MPIO1, MPIO2, MPIO5, MPIO6, MPIO7, MPIO10, and MPIO12 directions are restored comparing to the configuration shown in Figure Figure 17: Load Config—Configuration from File Updated MaxLinear Confidential March 15, 2024 030UMR00...
The URLs provided are for informational purposes only; they do not constitute an endorsement or an approval by MaxLinear of any of the products or services of the corporation or organization or individual. MaxLinear bears no responsibility for the accuracy, legality or content of the external site or for that of subsequent links.
Need help?
Do you have a question about the XR17V35 Series and is the answer not in the manual?
Questions and answers