Page 1
INSTRUCTION MANUAL Delivery table type LM-03 FREYA 3 Serial no.: ..................Revision 2.00 Publication date: 26.03.2015 FAMED śYWIEC Sp. z o.o. Annexes: 2, 3, 4, Index of Spare Parts.
Page 2
Instruction Manual for the Delivery Table FREYA 3 In line with the Council Directive 93/42/EEC of 14 June 1993 on medical devices, this is a class I device. The manufacturer declares that this device is compliant with the essential requirements contained in Annex I to the directive and Act on medical devices.
Page 3
Instruction Manual for the Delivery Table FREYA 3 Dear Customer! Congratulations on the right choice. We wish you satisfaction of operating our medical device. Please, do carefully read this manual, as it contains vital information and notes from the manufacturer, related to the proper installation, operation and maintenance.
Page 4
Instruction Manual for the Delivery Table FREYA 3 press your hand against the table elements near the moving elements of the structure. • If the patient lies on the table without being supervised by the medical staff, then the table should remain in the lowest position.
Page 5
Instruction Manual for the Delivery Table FREYA 3 While rolling the table, do not hold the plastic covers of the base nor lying surface frame, because it may damage the covers! Labour in the horizontal position should take place on the shortened lying surface, at least two steps from the max.
Instruction Manual for the Delivery Table FREYA 3 ABLE OF CONTENTS 1. PROPER USE AND APPLICATION ................7 1.1..............................7 PPLICATION 1.2..........................7 ENERAL REQUIREMENTS 1.3........................... 7 SER RESPONSIBILITIES 1.4............................. 7 ECHNICAL DATA 1.5....................... 8 ESCRIPTION OF THE UNITS AND FUNCTIONS 1.6.
Instruction Manual for the Delivery Table FREYA 3 Proper use and application 1.1. Application The delivery table LM-03 is intended for lying and sitting, for patients at all the stages of labour. This table comes equipped with the permanent and extended lying surfaces. The lying surface height, and angles of the backrest and seat sections, Trendelenburg and reverse Trendelenburg, are electrically adjusted.
Instruction Manual for the Delivery Table FREYA 3 1.5. Description of the units and functions Fig. 1 Item in fig. 1 Description Set base Permanent lying surface frame Extended lying surface frame Backrest section Side rail Headboard Basin Electrical columns for lifting the lying surface...
Instruction Manual for the Delivery Table FREYA 3 1.6. Medical device description The delivery table structure enables a quick position change into the armchair position, which reduces the preparation time for labour and ensures safety of the labour positions. The lying surface is made of lacquered steel with stainless elements.
Instruction Manual for the Delivery Table FREYA 3 • Avoid safety risks which may result from the improper use of the power cables/cords, e.g. tensioning the cables/cords, their squeezing in between moving parts, running over them. Below is the warning: "Warning! - Follow the instructions for safe use ".
2.2. Unpacking and first start-up If the device is mounted by the service team of FAMED śYWIEC Sp. z o.o., then the user is exempt from performing the activities described at this point. NOTE! The delivery table supplied by the manufacturer is pre-installed, in a box with these dimensions: length:~ 69 in (1,750 mm) x width:~47 in (1,200 mm) x height:~43 in (1,100 mm) and weight: ~38 st (240 kg).
Page 12
Instruction Manual for the Delivery Table FREYA 3 remove the equipment from the package, remove the caster locking elements, release the central caster locking device, with the help of another person, slowly and carefully remove the table off the pallet, subsequently –...
Instruction Manual for the Delivery Table FREYA 3 Operation During normal use, the table must obligatorily be connected to the mains. Additionally, the proper connection is indicated by a lit indicator (in the option where it is included), located in the base cover, above the power cord output from the delivery table base.
Page 14
Instruction Manual for the Delivery Table FREYA 3 When cleaning and disinfecting the delivery table, exercise extreme caution. Should the central panel keyboard be spilled over with water, some agents or other fluids, dry it, and wipe its edges dry with a cloth.
Page 15
Instruction Manual for the Delivery Table FREYA 3 If the patient is not attended to by the medical staff, lock the table functions activation of which may pose a threat to the patient safety. NOTE! 3.1.3. Control panels in the rails The side rails of the delivery table are equipped with control panels on the outer side (see Fig.
Instruction Manual for the Delivery Table FREYA 3 3.2. Lying surface lifting and lowering The lying surface height can be adjusted by means of an electric actuator. The lying surface stops automatically on reaching the minimum or maximum height. Control method: ♦...
Instruction Manual for the Delivery Table FREYA 3 3.4. Seat section angular position adjustment The seat angular position is adjusted by an electric actuator (fig. 1, item 8b). The seat section stops automatically on reaching the extreme angles. Control method: ♦...
Instruction Manual for the Delivery Table FREYA 3 3.7. Locking the delivery table functions The adjustment functions of the delivery table can be locked: lying surface height, longitudinal tilting, angle of the backrest and thigh sections. (Un)locking of the table functions can be performed by means of the central control panel, locking panel, or by use of the controller with the key (see descriptions of the control elements at 3.1 Electronic control system description).
Instruction Manual for the Delivery Table FREYA 3 3.12. Installation and removal of the foot support The foot support is used during labour and serves as a support for the labouring woman's feet. The support (fig. 1, item 16) can be twisted and pulled out of the extended lying surface frame, thus adjusting the foot support angle.
Instruction Manual for the Delivery Table FREYA 3 While rolling, the power cord should be coiled on the holder (fig 1, item 21), in order to avoid damage. The table should be rolled by at least two persons. Do not roll the loaded table (with a patient on) on inclined planes and outdoors.
Instruction Manual for the Delivery Table FREYA 3 3.16. Installation and removal of the lying surface mouldings In order to facilitate cleaning and disinfection, you can remove the mouldings of the permanent lying surface (fig.1, item 19) or seat (fig.1, item 20), as well as the extended lying surface mouldings (fig. 1, item 17).
Page 22
Instruction Manual for the Delivery Table FREYA 3 The mattresses are made of polyurethane foam encased in waterproof fabric. The mattresses can be encased in eco-leather/artificial leather or vapour-permeable fabric. The mattresses encased in eco-leather/artificial leather should be cleaned and disinfected acc. to the information provided in annex 2 to this instruction manual.
Instruction Manual for the Delivery Table FREYA 3 Utility parameters The schematic figure below presents the most important utility functions of the delivery table and their marking. Page 23...
6.2. Cleaning and disinfection For cleaning and disinfecting, use agents recommended by FAMED śYWIEC Sp. z o.o. in annex 2 to this instruction manual (admitted to trading and using in the country where they are applied). After disinfection, rinse the medical device with water so as to remove any stains.
Instruction Manual for the Delivery Table FREYA 3 The central control panel and side rail control panels should be dry cleaned. Washing and disinfecting should be performed only when necessary, with as little liquid as possible. When cleaning and disinfecting the controller, exercise extreme caution.
Page 26
Instruction Manual for the Delivery Table FREYA 3 Technical inspection scope Frequency functionality check every 12 months general technical state check So as to ensure safe and reliable functioning within the device lifetime, the user shall perform technical state inspections every six months acc. to the table below.
Instruction Manual for the Delivery Table FREYA 3 6.6. Troubleshooting Malfunction Possible cause Remedy table will not move locked casters, unlock the central locking device table will not be steered directional lock, unlock the central locking device CPR function will not start...
Instruction Manual for the Delivery Table FREYA 3 Electromagnetic environment characteristics Electromagnetic emissions The medical device: Delivery Table LM-03, is intended for use in the electromagnetic environment characterised by the following features: The user is to ensure that the medical device:...
Page 29
Instruction Manual for the Delivery Table FREYA 3 Electromagnetic immunity The medical device: Delivery Table LM-03, is intended for use in the electromagnetic environment characterised by the following features. The user is to ensure that the medical device: Delivery Table LM-03, is used in this type of environment.
Instruction Manual for the Delivery Table FREYA 3 Delivery table identification In case of any questions pertaining to the table and orders of spare parts, please provide the serial number, which can be found on the identification plate and in the warranty card.
Instruction Manual for the Delivery Table FREYA 3 8.2. Labels Central caster locking device Central control panel Backrest CPR lever see pt. 8.1 Identification plate Maximum load 34 st (215 kg) / 39 st (250 kg) Maximum load of the extended lying surface frame...
Page 32
Instruction Manual for the Delivery Table FREYA 3 Power supply 230 V~ Foot controller socket (option) Height adjustment pedal (option) Backrest inclination adjustment pedal (option) Seat inclination adjustment pedal (option) Warning! - Follow the instructions for safe use. Follow the instructions...
Page 33
Instruction Manual for the Delivery Table FREYA 3 Medical FREYA 3 device: June 2016 Revision: Index of spare parts SJW-4-01-02 Basic spare parts Item Part name Marking Delivery of parts Pcs. Category PVC impact absorber φ100/ φ15.5 Famed śywiec Sp. z o.o.