USER MANUAL Operating table SU-14 Factory number: ........…........…........Edition 10.00 Issuance date: March 2017 FAMED ŻYWIEC Spółka z o.o. Appendixes: 2, 3, List of Spare Parts.
Page 2
User manual for Operating table SU-14 As provided in the Directive on Medical Equipment 93/42/EEC of 14 June 1993 this is first risk class product. The producer declares that the product meets basic requirements of the directive contained in Appendix 1.
Page 3
User manual for Operating table SU-14 Dear Clients, Congratulations on choosing the right product, we wish you would find a lot of satisfaction while operating it. Please read this manual very carefully as it includes all the vital information and notes from the producer concerning proper installation and maintenance of the product as well as its service.
Page 4
When changing operation table's position you must avoid any collisions between the table and accessories. • Not original accessories may be applied only after consulting with Famed Żywiec company about their use. • Operation table's electrical conductivity must be checked once a year. The check should be carried out by trained service personnel.
Page 5
User manual for Operating table SU-14 • When batteries need to be exchanged, do always exchange a set of two batteries, exchange of a single battery causes limitation to operating time of a table and quick wear of a new battery.
User manual for Operating table SU-14 Contents PROPER USE AND APPLICATION ......................7 USE ................................. 7 GENERAL REQUIREMENTS ....................... 7 DUTIES OF THE USER .......................... 7 DESCRIPTION OF PRODUCT ....................... 7 COMPONENTS AND FUNCTIONS DESCRIPTION ................8 TECHNICAL DATA ..........................9 USE PARAMETER.…………………………………………………………………………………….
Proper use and application 1.1 Use Operating table SU-14 is designed for supporting the patient during carrying out treatments and operations. The table with the proper accessories can be used for treatments and operations in the range of general surgery, vascular surgery, cardio surgery, neurosurgery, urology, proctology, gynecology, laryngological, ophthalmology, endoscopies, laparoscopy, traumatic, oncology, dental, plastic surgery and others.
User manual for Operating table SU-14 Nr on fig.1 Description headrest backrest segment seat segment footrest segment basis headrest angle change lever table top handle blocking control of headrest backrest position angle change lever footrest blockade control footrest angle change lever...
Fig. 3 1.10 Electromagnetic compatibility Medical device the operating table SU-14 is an electric appliance. Electric appliances are a source of electromagnetic radiation and themselves are under its influence Therefore, use of an electric appliance requires some safety precautions connected with electromagnetic compatibility.
Page 12
User manual for Operating table SU-14 In tables: item 7 Characteristics of electromagnetic environment – electromagnetic environment in which medical device the table SU-14 should be used. Recommendations and warnings which should be followed by the users were also presented.
A label for foreign countries Fig. 3 Label “Transport position” Unpacking and first use If the Product is installed by service point of FAMED ŻYWIEC company, User is released from the responsibility to carry out procedures described in this section. Caution! The table is shipped by the producer in an assembled form in a wooden, open-work chest or in a cardboard box with the following dimensions L: 1340 x W:700 x H:890 mm and weight 160 kg.
Page 14
User manual for Operating table SU-14 Package may be marked with following signs: Caution! - multiuse package - package for recycling - low-density polyethylene packaging LDPE Packaging waste disposal should be carried out in accordance to environmental regulations, that are in force where the packaging containing the Product was delivered.
User manual for Operating table SU-14 Operation and use Controlling elements 3.1.1 Wire- connected control – Height adjusting Longitudinal movement – Side inclination – – Memory buttons – Record for memory button Fig.5 wire-connected control The wire-connected control is permanently connected to the controlling box at the table basis. The table is switch on through place the switching in “I „position (Fig.
User manual for Operating table SU-14 Raising and levering of table top The height of table top is changed within the range defined in technical data by pressing the button [1] or [2] of controller (wire-connected controller, wireless controller or side control panel). When the extreme position is reached, table top stops automatically.
User manual for Operating table SU-14 central position of the lever the backrest segment can be operated from the right, from the left and from behind the backrest segment. If a patient is very heavy, over 90 kg, the angle of backrest segment should be changed with particular care;...
User manual for Operating table SU-14 Inserting and Removing Footrest Footrest segments (Fig. 1, Pos. 4) can be attached and removed from the seat segment thanks to the mechanism activated by the lever (Fig. 1, Pos. 24). In order to remove the footrest segment, it should be grasped from underneath, the lever (Fig.1, Pos.
– By potential equalisation clamp. Operating table SU-14 should be used on antistatic floor. In case of lack of such floor, an electrostatic charge is drained through a potential equalization line. The potential equalising conductor is a standard table accessory.
User manual for Operating table SU-14 4 Installation and operation of accessories The following extra accessories may be provided with the operating table SU-14: Elements of accessories Symbol Screen frame WS-01.5 14 kg Screen frame with width regulation WS-01.6 14 kg Hand grip WS-02.5 17 kg...
User manual for Operating table SU-14 Criteria on whose basis it is assessed whether product operation is correct or not Correctness of table operation shall be checked every day before the beginning of its operation. Caution! The method of checking whether operation of the table is correct: 1.
The table may not be stored with batteries low Cleaning and disinfecting For cleaning and disinfecting use cleaners, disinfectants recommended by Famed Żywiec Sp. z o.o. in Annex 2 to this manual (allowed to turnover and use on the territory of the country, where they are used).
User manual for Operating table SU-14 Repairs and maintenance must be performed only by qualified personnel. If a product is operated outside Poland, one should inform about a necessity of a repair a producer or the dealer from whom the product was purchased.
User manual for Operating table SU-14 When to do the inspection: – the device has been repaired; – periodically (every 12 months) during technical inspection. To ensure safe and correct operation of the device during the service life, the user must perform technical checks listed below every 6 months.
Electromagnetic immunity Medical device operating table SU-14 is to be used in electromagnetic environment specified below. The customer or the users of medical device the SU-14 should assure that it is used in such an environment. IEC 60601-1-2 Immunity test Compliance level Electromagnetic environment –...
Page 26
Electromagnetic immunity Medical device operating table SU-14 is to be used in electromagnetic environment specified below. The customer or the user of medical device the SU-14 should assure that it is used in such an environment. IEC 60601-1-2 Immunity test Compliance level Electromagnetic environment –...
User manual for Operating table SU-14 8 Table identification When sending/ asking any questions concerning the table and when ordering spare parts, please give the serial number of the table placed on the nameplate and the guarantee certificate. 8.1 Nameplate Description of meanings of particular boxes of a name plate 1 –...
User manual for Operating table SU-14 8.2 Labels Page 28...
Page 29
Watch point 8.1 Name plate Transport position of the table (see point (see point 2.1) The method of battery charging Warning! - Follow the instructions for safe use. For clearing and disinfection you should not use agents containing active oxygen and chlorine Maximal workload 200 kg Central wheels blockade...
Page 30
Operating manual for Operating Table SU-12 Head rest adjustment Foot rest adjustment Hook for alimentation cable Follow the instructions Power socket Notice! The producer reserves the right to introduce in the product structural modifications resulting from technical progress which are not covered in this operating manual.
Page 31
August 2014 Edition: Spare Parts List SJW-4-01-02 Basic spare parts No. Name Code number Category Remarks Famed Żywiec Sp. z o.o. Column S09164004010310 Famed Żywiec Sp. z o.o. Control box S09164004020710 Famed Żywiec Sp. z o.o. Brake lever C043306000501/-02/ Famed Żywiec Sp. z o.o.
Page 32
Operating manual for Operating Table SU-12 Legend: Markers in column „Category” 1 - The elements endanger fast wear out 2 - The elements not endanger fast wear out 3 - The elements wear out depended of condition of exploitation Page 32...