![]() | Excellent air purification performance HEPA filter is capable of trapping airborne allergens and contaminants down to 0.3 microns. It reduces airborne bacteria, mold spores and particles that carry viruses. The unit's filter system has been optimized to remove indoor pollutants fast and effectively. |
![]() | Air quality indicator It shows the indoor air pollution level measured by the dust sensor. The color of air quality indicator changes according to the indoor air pollution level in real time (Blue → Purple → Red). |
![]() | Filter replacement indicator The product checks the filter replacement cycle and turns on the relevant indicator, improving customer convenience with regard to filter replacement. |
![]() | Timer The timer feature allows you to control how long you want the air purifier to run HEPA Odor before automatically powering off. FILTER RESET |
Front / Rear
Operation / Indication part
Air quality indicator
![]() | ![]() | ![]() |
Clean: Blue | Polluted: Purple | Highly polluted: Red |
Operation / Indication part
Air purification system
Please check before use!
The product is for 120 V~, 60 Hz only.
Make sure to connect the power plug to a grounded electric outlet (120 V~, 60 Hz) dedicated to the product.
How to Install Filter
Tips
Tips
Manual & Auto mode
Press the power button and then select the speed of the fan by pressing the speed button. Auto → 1 → 2→3.
► Auto mode
Automatically optimizes the speed setting 1 through 3 based on the level of indoor air quality detected by dust sensor. This mode is recommended for general users.
Timer activation/deactivation
The Timer feature instructs the air purifier to automatically power off after 1, 4, 8 or 12 hours.
When the product is shipped out, the air quality sensor is set to standard sensitivity. If the pollution level stays at the highest level after 2 hours of operation or stays at the lowest level for more than 1 hour when the air does not seem clean, users can adjust the sensitivity of the air quality sensor as follows.
Speed step 1 | Speed step 2 | Speed step 3 |
High | Standard | Low |
Tips
Cleaning the air quality sensor (every 2 months)
Cleaning the air inlet and outlet (every 2 months)
Clean the air inlet and outlet with a soft brush.
Cleaning the front cover
Separate the front cover from the product and remove the dust attached to the surface with a soft dry brush or cloth.
Cleaning the product body (every 2 ~ 4 weeks)
Use dry, soft cloth to clean the product.
Tips
Cleaning the pre-filter (every 2 ~ 4 weeks)
Tips
Filter cleaning and replacement cycles
Filter | Cycles | Method |
Pre-filter | Every 2~4 weeks | Cleaning |
Odor filter | Every 6 months | Replacement |
HEPA filter | Every 1 year | Replacement |
Resetting the filter replacement indicator
Forcible reset mode
When you have replaced a filter before the filter replacement cycle is reached, you can forcibly reset the filter replacement cycle back to the factory default setting.
The air purifier may operate abnormally not because of the product malfunction but because of minor causes or the fact that the user is not familiar with the product use. In such a case, problems can be solved easily even without the help from the service center just by checking the following. If the problem still persists after you check the following, contact the service center.
Problems | Check | Possible solutions |
No air is blowing |
| Connect the power cord to an electric outlet for 120 V~, 60 Hz. |
| Press the power button and then select the desired function. | |
| Use the air purifier after the power comes back on. | |
| Close the front cover properly. | |
The airflow speed does not change |
| Set the desired operating mode. |
The airflow speed is significantly weaker than before |
| Check the filter cleaning and replacement cycles and then clean/replace the filter(s) if necessary. |
A bad smell comes out of the air outlet |
| Check the filter cleaning and replacement cycles and then clean/replace the filter(s) if necessary. |
The color of the pollution level indicator always stays the same. |
| Clean the lens of the pollution sensor. |
| Adjust the sensitivity of the pollution sensor to Insensitive or standard. | |
| Adjust the sensitivity of the pollution sensor to sensitive or standard. | |
When other functional problems are detected |
|
Product specification | Air Purifier |
Model | AP-1216L |
Rated voltage | 120 V~, 60 Hz |
Phase | Single phase |
Power consumption | 55 W |
Product insulation grade | Grade 2 device |
Dust collection method | Mechanical dust collection method (HEPA filter) |
Safety feature | Fan motor is shut down when front cover is open. |
Installation place | Indoor use |
Maximum volume of air | 268.39 ft 3 /min |
Size | 10.83inch(W)X10.63inch(D)X32.88inch(H) |
Weight | 14.3lbs |
► Specifications are subject to change without notice.
Failing to follow the precautions below may result in serious injury or even death.
Failing to follow the precautions below may result in considerable physical injury or property damage.
Failing to follow the precautions below may result in slight physical injury or property damage.
READ AND SAVE THESE INSTRUCTIONS
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the P-1216L that isn't answered in the manual? Leave your question here.