Safety Information - Pioneer VSX-D307 Service Manual

Audio/video multi-channel receiver
Hide thumbs Also See for VSX-D307:
Table of Contents

Advertisement

VSX-D307
1. SAFETY INFORMATION
This service manual is intended for qualified service technicians ; it is not meant for the casual do-it-
yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained
to properly and safely repair complex products such as those covered by this manual.
Improperly performed repairs can adversely affect the safety and reliability of the product and may
void the warranty. If you are not qualified to perform the repair of this product properly and safely, you
should not risk trying to do so and refer the repair to a qualified service technician.
WARNING
Lead in solder used in this product is listed by the California Health and Welfare agency as a known reproductive toxicant which may
cause birth defects or other reproductive harm (California Health & Safety Code, Section 25249.5).
When servicing or handling circuit boards and other components which contain lead in solder, avoid unprotected skin contact with
the solder. Also, when soldering do not inhale any smoke or fumes produced.
NOTICE
(FOR CANADIAN MODEL ONLY)
Fuse symbols -§§—#- (fast operating fuse) and/or -§—#4 (slow operating fuse) on PCB indicate that replacement parts must
be of identical designation.
REMARQUE
(POUR MODELE CANADIEN SEULEMENT)
Les symboles de fusible -§-—H (fusible de type rapide) et/ou -§E—# (fusible de type lent) sur CCI indiquent que les piéces
de remplacement doivent avoir la méme désignation.
(FOR USA MODEL ONLY)
1. SAFETY
PRECAUTIONS
ANY MEASUREMENTS
NOT WITHIN THE LIMITS
The following check should be performed for the
OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL
continued protection of the customer and service
SHOCK HAZARD AND MUST BE CORRECTED BEFORE
technician.
RETURNING THE APPLIANCE TO THE CUSTOMER.
LEAKAGE CURRENT CHECK
Measure leakage current to a known earth ground (water
2. PRODUCT
SAFETY
NOTICE
pipe, conduit, etc.) by connecting a leakage current tester
such as Simpson Model 229-2 or equivalent between the
earth ground and all exposed metal parts of the appliance
(input/output terminals, screwheads, metal overlays, control
shaft, etc.). Plug the AC line cord of the appliance directly
into a 120V AC 60Hz outlet and turn the AC power switch
on. Any current measured must not exceed 0.5mA.
Many electrical and mechanical parts in the appliance
have special safety related characteristics. These are
often not evident from visual inspection nor the protection
afforded by them necessarily can be obtained by using
replacement components rated for voltage, wattage, etc.
Replacement parts which have these special safety
characteristics are identified in this Service Manual.
Electrical components having such features are identified
\
by marking with a A\ on the schematics and on the parts list
o
Reading should
in this Service Manual.
;
Leakage Helen above
The use of a substitute replacement component which does
Oey thea
ltl
not have the same safety characteristics as the PIONEER
recommended replacement one, shown in the parts list in
Test all
this Service Manual, may create shock, fire, or other hazards.
euulaces
instructions are issued from time to time. For the latest
information, always consult the current PIONEER Service
Also test with
Manual. A subscription to, or additional copies of, PPONEER
AC Leakage Test