1.2 In the Box Gimbal Camera USB to TTL Cable x 1 pc x 1 pc Copper Cylinder M3 Screw x 4 pcs x 8 pcs Power Cable x 1 pc PWM Control Cable x 1 pc @2022 FOXTECH All Rights Reserved 1...
SYK 30 TIR EO/IR Camera Manual TTL / S.BUS Control Cable x 1 pc TTL Connect Cable x 3 pcs Ethernet Cable x 1 pc 2. Installation Instruction 2.1 Overview [14] [11] [10] [13] [12] @2022 FOXTECH All Rights Reserved 2...
Page 4
Please remove the obstacle immediately if gimbal camera is blocked during rotation. Don’t put the infrared thermal camera towards the sun in case any burn to the camera 2.2 Control Box Printing Front Side @2022 FOXTECH All Rights Reserved 3...
Page 5
SYK 30 TIR EO/IR Camera Manual POWER Left Side ETHERNET UART & S.BUS Right Side @2022 FOXTECH All Rights Reserved 4...
Page 6
SYK 30 TIR EO/IR Camera Manual 2.3 Device Dimensions Unit: mm 41.6 Control Box 127.7 @2022 FOXTECH All Rights Reserved 5...
Page 7
(3) According to the provided screw hole dimension you can make suitable mounting holes on the UAV mounting board, and fixes the other end of the copper cylinder on the mounting board of the UAV. Front @2022 FOXTECH All Rights Reserved 6...
Page 8
1. Make sure the two white stripes indicated in above picture are aligned with each other. (If the stripes are not aligned to each other, please pinch the connector part and turn it to left manually) @2022 FOXTECH All Rights Reserved 7...
Page 9
4. To unlock the board, you need to press on unlock button and rotate the gimbal camera clockwise till the white dot align to the red triangle. Then pull the gimbal out from the board. @2022 FOXTECH All Rights Reserved 8...
Page 10
Default: RTSP output, IP address: RTSP: //192.168.2.119:554, output resolution: 720P (record in 1080p), frame rate: 25fps, bit rate: 2M. (Optional) SDI: SMA outer screw inner hole interface, 1080P 30fps output. (Optional) AV: no AV output @2022 FOXTECH All Rights Reserved 9...
7 PWM channels). You can choose needed functions according to actual usage to reduce the required number of PWM channels. 3.1.1 PWM Connection Diagram (Connect pitch chan- nel as example) @2022 FOXTECH All Rights Reserved 10...
SYK 30 TIR EO/IR Camera Manual Receiver Remote Controller Connection Diagram @2022 FOXTECH All Rights Reserved 11...
Page 13
Yaw Stop Yaw Right 3) Mode (PWM Mode channel in to adjust speed control/one key to Home position etc functions. Rotary knob or 3-gear switch on remote control are optional. 3-gear switch as example.) @2022 FOXTECH All Rights Reserved 12...
Page 14
3.4) Operate 4 times continuously and quickly, from position 2 - 3 - 2 - 3 - 2 - 3 - 2 - 3 - 2, to enable Follow Yaw Mode (gimbal yaw follows by frame) @2022 FOXTECH All Rights Reserved 13...
Page 15
Switch from Position 2 to 3: IR color switching: white hot, black hot, pseudo color. 6) Pic/Rec (PWM Pic/Rec channel in to control take picture and record. Joystick, rotary knob or 3-gear switch on remote control are optional. 3-gear switch as example.) @2022 FOXTECH All Rights Reserved 14...
Page 16
Switch from Position 2 to 1: IR digital zoom, 1x~4x Switch from Position 2 to 3: Exit the tracking, display the cross cursor. Adjust the cross cursor to lock target object and start tracking Switch from Position 3 to 2: Cancel tracking @2022 FOXTECH All Rights Reserved 15...
Page 17
TTL communication requirements: TTL signal is 3.3V, baud rate: 115200, data bit 8, stop bit 1, no parity, HEX send and receive. Connection Diagram (PC - USB to TTL Cable- Gimbal Camera as example): USB to TTL Cable Control Box Connection Diagram @2022 FOXTECH All Rights Reserved 16...
Connect the external S.Bus to S.Bus port on the control box, and the external S.bus signal GND connect to the GND interface of the control box. Wiring Diagram (Take Futaba remote control for example): @2022 FOXTECH All Rights Reserved 17...
PWM function description) Channel 9: Yaw Control Channel 10: Pitch Control Channel 11: Mode Control Channel 12: Zoom Control Channel 13: Focus Control Channel 14: Pic/Rec Control Channel 15: Multi Backup @2022 FOXTECH All Rights Reserved 18...
Page 20
(serial port protocol) + Checksum (CS = body checksum, checksum is calculated as a sum of all bytes of data body modulo 256)]. Or directly use UI Viewlink to control after TCP connection. @2022 FOXTECH All Rights Reserved 19...
JPG(1920*1080) MP4 (1080P/720P 25fps/30fps) Video storage format PWM / TTL / S.BUS / TCP(IP output) Control method Gimbal Spec Pitch/Tilt: -40°~110°, Roll: ±70°, Mechanical Range Yaw/Pan: ±300° / ±360°*N (IP / SDI output version) @2022 FOXTECH All Rights Reserved 20...
Page 22
SD: 47.8°(wide end) ~ 1.7°(tele end) Sync system Internal S/N ratio more than 50dB Min illumination Color 0.01lux@F1.6 Auto, Manual, Priority mode (shutter priority & iris priority), Exposure control Bright, EV compensation, Slow AE @2022 FOXTECH All Rights Reserved 21...
Page 23
16 steps Defog Camera Object Tracking Update rate of 50Hz deviation pixel Output delay of deviation pixel Minimum object contrast Minimum object 32*32 pixel size Maximum object 128*128 pixel size Tracking speed 32 pixel/frame @2022 FOXTECH All Rights Reserved 22...
Page 25
0℃~120℃ (For thermometry version only) Thermal Imager Object Tracking Update rate of 50Hz deviation pixel Output delay of deviation pixel Minimum object size 32*32 pixel Maximum object size 128*128 pixel Tracking speed 32 pixel/frame @2022 FOXTECH All Rights Reserved 24...
Page 26
Object memory time 100 frames (4s) Packing Information N.W. 1395g Product meas. 127.6*164.5*173.5mm 1pc gimbal camera device, 16pcs screws, 4pcs copper cylinders, 12pcs damping Accessories balls, 4pcs damping boards, 1pc USB to TTL cable / box @2022 FOXTECH All Rights Reserved 25...
Page 27
5. How to modify the code stream parameters of SYK-30 IP output? A: You can use the movement configuration tool to set the resolu- tion, bit rate, push mode,Video encoding format, network port output frame rate, encoding packet format, storage format. @2022 FOXTECH All Rights Reserved 26...