Error retrieval
1. Auto Lock
If desk is taken through 5 full cycles in a row, it will be automatically locked to prevent overheating. It needs to be powered off and on again to
continue the use.
2. Error Code Form
Error Code
Reason
E01
Motor is not
connected
E02
Motor overcurrent
E03
Motor Hall failure
E04
Abnormal main
power supply
E05
Abnormal motor
current
E06
Motor power device
failure
E08
Over temperature
protection
E09
Motor blocked
RST
Frequent power
failure
3. Abnormal functioning (abnormal noise or wobble)
Check whether the table legs are perpendicular to the table top, than re-tighten the upper table legs screws and inclined strut screws.
EN
Solution
Please check if the motor cable is connected
After power is off, reconnect all cables. Press
5 seconds to restore factory settings.
After power is off, reconnect all cables. Press
5 seconds to restore factory settings.
After power is off, reconnect all cables. Press
5 seconds to restore factory settings.
After power is off, reconnect all cables. Press
5 seconds to restore factory settings.
After power is off, reconnect all cables. Press
5 seconds to restore factory settings.
Suspend the use for 15 minutes ,wait for the temperature to drop. After power is off,
reconnect all cables.
After power is off, reconnect all cables. Press
5 seconds to restore factory settings.
Check whether the power cord is loose. Restore factory settings.
EN
and
keys at the same time for
and
keys at the same time for
and
keys at the same time for
and
keys at the same time for
and
keys at the same time for
and
keys at the same time for
Need help?