GatesAir Intraplex DS-961DF Installation And Operation Manual

Five-port multi-rate synchronous data module

Advertisement

Quick Links

Installation and Operation Manual
Intraplex®
DS-961DF/DG Five-Port
Multi-Rate Synchronous Data Module
DS-961DF/DG Five-Port Multi-Rate Synchronous Data Module
Version 1.3
GatesAir.com

Advertisement

Table of Contents
loading

Summary of Contents for GatesAir Intraplex DS-961DF

  • Page 1 Installation and Operation Manual Intraplex® DS-961DF/DG Five-Port Multi-Rate Synchronous Data Module DS-961DF/DG Five-Port Multi-Rate Synchronous Data Module Version 1.3 GatesAir.com...
  • Page 3 ©2014 GatesAir, Inc. . Proprietary and Confidential. GatesAir considers this document and its contents to be proprietary and confidential. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of GatesAir.
  • Page 4 Versio Date Revisions Made Editor 6/30/ Put entire manual into new template, reformatted, and Lacona Darrah updated with ISDN information and clarification for CM5/7 and CM11 on Jumper 7. *Version numbers usually correspond to software releases. If the manual versions differ in number from the release, the front page shows both the manual version and the release version.
  • Page 5: Table Of Contents

    3.2.3 Remote Control Configuration ..............3-2 3.3 Mounting ..................3-2 Section 4 – Testing ................ 4-1 Section 5 – Specifications .............. 5-1 NOTICE OF FCC COMPLIANCE ..............5-1 Appendix A - Module Adapter – DS-961DF/DG ......A-1 GatesAir Intraplex Products...
  • Page 6 Table 2-7. Card Address Setting - SW1, Positions 1 - 6 ........2-7 Table 2-8. Remote Configuration Settings (P Codes) in T1 Mode ....... 2-9 Table 2-9. Remote Configuration Settings (P Codes) in DDS/ISDN Mode ..2-10 Table 2-10. Remote Configuration Settings (S Codes) in DDS/ISDN Mode ..2-11 GatesAir Intraplex Products...
  • Page 7: Section 1 - Introduction

    No header here Section 1 - Introduction This manual describes the setup and installation procedures for the Intraplex DS-961DF/DG Five-Port Multi- Rate Synchronous Data Module. Experienced users may refer directly to the tables in Section 2 for configuration data. As of January, 2006, the DS-961DF module is no longer in production. Functionally, the DS-961DF and DS-961DG modules are identical.
  • Page 8 DS-961DF/DG Five Port Multi-Rate Synchronous Module Section 1- Introduction Version 1.3 GatesAir Intraplex Products...
  • Page 9: Section 2 - Functional Description & Setup

    9600 bps Figure 2-1 shows a simplified block diagram of the DS-961DF/DG. Figure 2-1. DS-961DF/DG Data Module, Block Diagram Note: The DS-961DF/DG is compatible with the DS-961D when jumper 7 is in CM-5 mode. GatesAir Intraplex Products...
  • Page 10: Transmit Side

    DOWN. However, when it is installed in a drop and insert multiplexer (Site 2), the TERM switch setting must be DOWN to transmit and receive via the DI/A port (toward Site 1) and UP to transmit and receive via the DI/B port (toward Site 3). GatesAir Intraplex Products...
  • Page 11: Controls And Indicator Lights

    The DS-961DF/DG has these features (Figures 2-3 and 2-4): ● Three switch banks ● Seven setup jumpers ● Four indicator lights Tables 2-1 through 2-6 describe the meaning and usage of these controls and indicator lights. Figure 2-3. DS-961DF/DG Data Module, Front View GatesAir Intraplex Products...
  • Page 12: Figure 2-4. Ds-961Df/Dg Data Module, Top View

    DS-961DF/DG Five Port Multi-Rate Synchronous Module Section 2- Functional Description & Setup Version 1.3 JMP1: NORMAL 3-CHANNEL Figure 2-4. DS-961DF/DG Data Module, Top View GatesAir Intraplex Products...
  • Page 13: Table 2-1. Indicator Lights

    Port 5 Fixed Output Level 1 – 2 MA-404 Pin 3 provides constant mark voltage T1 Operation 1 – 2 (CM5/7) DDS and ISDN Operation 2 – 3 (CM11) When using Intraplex CM-10 and CM-11 common modules GatesAir Intraplex Products...
  • Page 14: Table 2-4. Configuration Switches

    D U D U U U D U U D D U D U D U D U D U D U D D U U D U D D D U D D D *U = UP, D = DOWN GatesAir Intraplex Products...
  • Page 15: Table 2-6. Rate Select - Sw3, Positions 1 - 3

    In a full size shelf, it is generally set to the physical slot number the card occupies. It may be set to any number from 1 to 36, which is not in use by another card in the same multiplexer. GatesAir Intraplex Products...
  • Page 16: Remote Control Interface

    In addition to the P codes, you can also turn service on or off for the card by sending SRVC = ON or SRVC = OFF in the parameter field of a SET command. Table 2-8 lists the meaning of all the P codes for this module. Table 2-9 lists the P codes used in DDS/ISDN mode. GatesAir Intraplex Products...
  • Page 17: S Codes

    The input buffers must be used when the DTE device timing is in use, so this code sets both of these conditions. Note 3 These codes are active only when internal timing is selected (P5 = 0). GatesAir Intraplex Products...
  • Page 18: Table 2-9. Remote Configuration Settings (P Codes) In Dds/Isdn Mode

    INV E B 0 0 0 0 0 0 0 0 DOWN = LOOPBACK ON  UP = LOOPBACK OFF LOOP Make sure that jumper 7 is in the 2-3 position for DDS/ISDN systems (Table 2-3). 2-10 GatesAir Intraplex Products...
  • Page 19: Table 2-10. Remote Configuration Settings (S Codes) In Dds/Isdn Mode

    B 0 0 0 0 0 0 0 0 The card is in frame.  The card is out of frame. B 0 0 0 0 0 0 0 0 No transmission alarm.  Transmission alarm GatesAir 2-11 Intraplex Products...
  • Page 20 DS-961DF/DG Five Port Multi-Rate Synchronous Module Section 2- Functional Description & Setup Version 1.3 2-12 GatesAir Intraplex Products...
  • Page 21: Section 3 - Installation

    7. Select the buffer in/timing using SW3/position 4. If using three-channel mode, this position should be 8. If using internal DS-961DF/DG module timing, set each channel to NORMAL or inverted clock using SW3/positions 5 - 9. 9. Set the loop switch UP, SW3/position 10. GatesAir Intraplex Products...
  • Page 22: Local Control Configuration

    Insert the module into the selected slot in the Intraplex multiplexer. Warning! The module must be inserted so that the white ejector tab is at the bottom in a full size (5¼" high) shelf, or at the right in a compact (1¾" high) shelf. GatesAir Intraplex Products...
  • Page 23: Section 4 - Testing

    If there is an apparent malfunction during end-to-end testing, first check that the configuration at the two ends is identical. Most problems occur at the common equipment or facility level. The Troubleshooting section in your multiplexer operation manual gives system analysis procedures. GatesAir Intraplex Products...
  • Page 24 DS-961DF/DG Five Port Multi-Rate Synchronous Module Section 4- Testing Version 1.3 GatesAir Intraplex Products...
  • Page 25: Section 5 - Specifications

    Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense. GatesAir Intraplex Products...
  • Page 26 DS-961DF/DG Five Port Multi-Rate Synchronous Module Section 5 - Specifications Version 1.3 GatesAir Intraplex Products...
  • Page 27: Appendix A - Module Adapter - Ds-961Df/Dg

    Note: If the Buffer In mode is selected and jumpers JMP2-6 are jumpered 2 to 3 on the DS-961DF, the terminal timing input is selected. If JMP2-6 are jumpered 1 to 2, pin 3 is a fixed RS-232 output level. GatesAir Intraplex Products...
  • Page 28: Figure A-2. Ma-404 Module Adapter, Jumper Settings

    DS-961DF/DG Five Port Multi-Rate Synchronous Module Appendix – DS-961DF/DG Version 1.3 JMP1 JMP2 JMP3 NORMAL THREE CHANNEL JMP1 JMP1 JMP2 JMP2 JMP3 JMP3 Figure A-2. MA-404 Module Adapter, Jumper Settings GatesAir Intraplex Products...