4.1 Connection to LPG
Use a pressure regulator and make the connection to the tank
according to the provisions of standards regulations in force. Make
sure that feed pressure conforms to the levels shown in the table in
paragraph "5.2 Regulation for LPG".
4.2 Ventilation of rooms
The hob may be installed only in rooms with permanent ventilation,
as required by standards regulations in force. The room in which
the hob is installed must have sufficient air flow to satisfy the
requirements of normal gas combustion and of necessary air
exchange in the room. The air intakes, protected by screens, must
be appropriately sized (regulations in force) and placed so as not to
be blocked in any way. The room where the oven is installed should
be suitably ventilated to avoid overheating or excess humidity
produced by cooking, and in the case of lengthy use a window
should be opened or the speed of any ventilators should be
increased.
4.3 Discharge of combustion products
Discharge of combustion products must be guaranteed by means of
hoods connected to a natural draught flue with certain efficiency, or
by means of forced aspiration.
An efficient aspiration system requires careful planning by a
specialist capable of installing it, respecting the positions and
distances prescribed by standards. After installation, the installer
must issue a certificate of conformity.