Lincoln Electric Flextec 500X CE Operator's Manual page 6

Table of Contents

Advertisement

ECO design information
The equipment has been designed in order to be compliant with the Directive 2009/125/EC and the Regulation
2019/1784/EU.
Flextec 500x CE
idle state,
set the Weld Terminals to off and Local/Remote to remote and wait until the fan is off. The fan will be off when
the units are powered up, or will turn off after a delay of (up to) 5 minutes if the welding output was just disabled.
The value of efficiency and consumption in idle state have been measured by method and conditions defined in the
product standard EN 60974-1
Manufacturer's name, product name, code number, product number, serial number and date of production can be read
from rating plate and serial number label.
Typical gas usage for MIG/MAG equipment:
Material type
diameter
Carbon, low alloy
0,9 - 1,1
steel
Aluminum
0,8 - 1,6
Austenitic stainless
0,8 - 1,6
steel
Cooper alloy
0,9 - 1,6
Magnesium
1,6 - 2,4
Tig Process:
In TIG welding process, gas usage depends on cross-sectional area of the nozzle. For comonly used torches:
Helium: 14-24 l/min
Argon: 7-16 l/min
Notice: Excessive flow rates causes turbulence in the gas stream which may aspirate atmospheric contaminantion into
the welding pool.
Notice: A cross wind or draft moving can disrupt the shielding gas coverage, in the interest of saving of protective gas
use screen to block air flow.
End of life
At end of life of product, it has to be disposal for recycling in accordance with Directive 2012/19/EU (WEEE), information
about the dismantling of product and Critical Raw Material (CRM) present in the product, can be found at:
www.lincolnelectriceurope.com
ECO design information
Efficiency and idle power consumption:
Efficiency when max power
Name
consumption / Idle power
Wire
DC electrode positive
Current
[mm]
[A]
95 - 200
90 - 240
85 - 300
175 - 385
70 - 335
consumption
89.5% / 75W
Wire Feeding
Voltage
[m/min]
[V]
18 - 22
3,5 – 6,5
18 - 26
5,5 – 9,5
21 - 28
3 - 7
23 - 26
6 - 11
16 - 26
4 - 15
1
Equivalent model
Flextec 500x with
CE filter
Shielding Gas
Ar 75%, CO
25%
2
Argon
Ar 98%, O
2% /
2
He 90%, Ar 7,5% CO
2,5%
2
Argon
Argon
ECO design information
Gas flow
[l/min]
12
14 - 19
14 - 16
12 - 16
24 - 28

Advertisement

Table of Contents
loading

This manual is also suitable for:

1280712808

Table of Contents