( ) Referring to Pictorial 3, place a solder lug on the right hand spade bolt as viewed from the
bottom, adda 6-32 nut and tighten.
—_
On the left hand spade bolt, place a 2-lug terminal strip TD, a lockwasher and nut.
Posi-
tion as shown in Pictorial 3.
~_
Solder a 1 3/4" length of shield braid directly on the chassis and sub-chassis as shown in
Pictorial 3.
{ ) Mount the pilot light in the upper right panel hole, as viewed from the front.
See Figure 7
for method of mounting
fo)
( ) Mount
the three
shielded
onnectors in the holes marked AF IN, AF
OUT,
and RF OUT.
8
NOTE:
The controls are
mounted
through both the chassis and panel and hold the panel to the
chassis.
Refer to Figure 5 for method of mounting
controls.
The controls
are
lettered
the
Same as the hole markings on Figure 6.
( ) Mount the two position EXT-INT modulation switch in hole K.
Position terminals
as shown
in Pictorial 3.
( ) Mount
the 1 megohm potentiometer L in hole L, and position terminals as shown in Picto-
rial 3.
( ) Mount the 1 K® control M in hole M, and position terminals as shown in Pictorial 3.
~_
_—
Mount
the three position attenuator switch N in hole N, and position terminals as shown in
Pictorial 3.
7
=| —~
ay,
© Gea)
Ye
@)
¢
ay
GROUND
~
Ce
HOT
LUG
N ~
PILOT
LIGHT
ASSEMBLY
Figure 7
Figure
8
ee
WIRING
OF
CHASSIS
eu
NOTE:
Exercise care when wiring chassis to avoid damage to E band coils.
) \
( ) Twist
the two black wires from the power transformer together and connect either wire to
TB3 (NS).
( } Connect the other black wire to TB1 (NS).
( ) Connect
a .01 pfd (10,000 wyf) ceramic
condenser from TB3 (NS) to the solder lug on the
opposite side of hole F (NS).
( ) Connect a .01 ufd ceramic condenser from TB2 (NS) to the same solder lug (S).
( ) Connect either red wire from the transformer
to the negative selenium rectifier terminal.
(The terminal nearest the chassis. ) (S).