9
Programming Menu
To save the settings and return to the normal operation mode, press and re-
lease the trigger. Otherwise press the MODE button to move to the Emissivity
parameter.
9.4 Setting the Emissivity
If you are continuing from the previous menu, use the arrow buttons to set the
emissivity value between 0.01 to 1.00 and use the LOG button to select a pre-
set location (see Figure 9.2).
To access this setting with the meter off, pull and release the trigger to enter
the HOLD mode, long press the MODE button to enter the program menu,
and then press the MODE button twice. Now use the arrows to set the emis-
sivity. See Section 7.6 for additional Emissivity information.
Figure 9.2 Setting the emissivity value and selecting a preset.
To save the setting and return to the normal operation mode, press and re-
lease the trigger. Otherwise press the MODE button to move to the tempera-
ture units parameter.
9.5 Setting the Temperature Units
If you are continuing from the previous menu, use the arrow buttons to select
℃ or ℉.
To access this setting with the meter off, pull and release the trigger to enter
the HOLD mode, long press the MODE button to enter the program menu,
and then press the MODE button three times. Now use the arrows to select
the unit of measure.
18
#NAS100131; r. AC/92852/92852; en-US