Page 1
Iss.0 3 P e r s o n T i e O f f P o s t Instruction Manual Models of device covered GM-200A GM-135 GM-135CP GM-136 GM138 Read and understand instructions before using this equipment Do not throw instructions away...
Page 2
Contents About & Warning Fall arrest systems General use Operation and Use Cleaning & Inspection Records & Service Log Table Lubrication Schedule...
Page 3
8&9 Operating instructions Examination and General Specification Checklist Description maintenance Base Plates Declaration of Conformity...
Page 4
ABOUT & WARNING The Safehold Three Person It is essential for the safety of the user that if the product is re-sold Tie off Post is a three person outside of the UK, the reseller anchor or two person recovery...
Any equipment must be as the serious injury or death. If in doubt, manufacturer intended. Do not use contact SafeHold Ltd. for advice. altered or modified equipment. All authorised users must reference Repairs must only be carried out...
If large enough ground clearance. in doubt contact SAFEHOLD LTD. Never remove a products label as for advice. it contains information important to the use of the device. If the label Always ensure a potential fall path...
Page 7
Tie-Off Mast, environmental conditions. after a fall; periodic examination recommended that the periodic shall only conducted examination frequency be at least SafeHold Ltd. or by a competent every 6 months. person authorised by SafeHold...
Weight: 11.7 kg / 26 lbs. • Tie-Off height is 1.9m (75 inches) from the walking surface. • Locks onto SafeHold Anchor Bases with 2 locking pins. • Maximum working load:140 kg / 350 lbs per person, maximum 300kg / 660lbs.
Page 9
Lower Mast a Shock Absorber installed on Section. The Lower Mast Section is the inner side of the Lower Mast pinned on to the SafeHold Anchor Section. The Upper Mast Section Base. is pinned to slide along the slots...
Page 10
It is the responsibility of the user / operator of this equipment to inspect all components of the Tie-Off Mast before each use. Never use the Tie-Off Mast if it’s damaged or displays excessive wear. Any questions regarding operation, maintenance or loading conditions contact SafeHold.
Before each use: Proper Fall Arrest System components are required using a full body harness and a fall arrest system with a maximum arrest force (M.A.F) 6kN peak / 1350lbs and 4kN / 900lbs average. Check whether the pin connecting the Upper Mast Section & Lower Mast Section is at the top of the slot.
Page 12
This device person. The inspection should must be inspected according to be recorded on the enclosed SAFEHOLD's recommendations schedule. Connect only to fall for safe use. Prior to each use it arrest attachment of a full body should be checked by the user harness.
Page 13
TIE OFF POST SERVICE LOG Serial No: Date of first issue: Model #: User: Date Results/Condition: Inspected by: Next Inspection Date:...
APPENDIX A - ANCHOR BASES AND ACCESSORIES GM135 For use on transformers. Double pin style plate that is welded to top surface of transformer for permanent mounting. GM135CP For use on transformers. Double pin style plate that fits Waukesha Power transformers.
EU DECLARATION OF CONFORMITY This declaration of conformity is issued under the sole responsibility of the manufacturer: SAFEHOLD LTD: Unit 15, Regis Ind Estate, Dorset Road, Sheerness, Kent, ME12 1LY. sales@safe-hold.com +44 (0) 1795 668862 Model No. GM200A/GM135/GM135CP/GM136/GM138 Part Code...