Fault
F
NL
I
N
S
‡ No suction power during wet
cleaning
DK
‡ Voltage fluctuations
SF
E
P
GR
TR
SLO
HR
SK
CZ
PL
H
RO
BG
RUS
EST
LV
LT
AL
MK
SR
UK
20
Cause
> Seal/tank rim between the
upper section of the cleaner
and the dirt tank is dirty/
defective.
> Filter bag is full.
> Filter element is clogged.
> Tank is full (floater closes the
suction opening).
> Impedance of power supply is
too high.
Remedy
Clean/replace seal.
See section "Replacing the
filter bag".
See section "Cleaning the filter
element" and "Replacing the
filter element".
Switch off the cleaner. Empty
the tank.
Use a suitable extension cord
(see section "Technical data").
Connect the cleaner to another
socket closer to the fuse box.
Voltage fluctuations over 7
% should not occur if the
impedance at the transfer point
is ≤ 0.15 Ω.