Backplates And Backplanes - Lenovo ThinkSystem SR250 V3 System Configuration Manual

Hide thumbs Also See for ThinkSystem SR250 V3:
Table of Contents

Advertisement

Status
On
Blinking
Off
4
System ID button/LED (blue)
Use this system ID button and the blue system ID LED to visually locate the server. Each time you press the
system ID button, the state of the system ID LED changes. The LED can be changed to on, blinking, or off.
You can also use the Lenovo XClarity Controller or a remote management program to change the state of the
system ID LED to assist in visually locating the server among other servers.
5
System error LED (yellow)
The system error LED helps you to determine if there are any system errors.
Status
Color
On
Yellow
Off
None

Backplates and backplanes

Use this information to identify the backplate or the backplane you use.
Backplate, four 3.5-inch simple-swap drives (connects to onboard connectors)
Figure 11. Backplate, four 3.5-inch simple-swap drives (connects to onboard connectors)
ThinkSystem SR250 V3 System Configuration Guide
26
Color
Description
Green
The server is connected to a network.
The network is connected and active.
Green
None
The server is disconnected from the network.
Description
An error has been detected on the server.
Causes might include one or more of the
following errors:
• The temperature of the server reached
the non-critical temperature threshold.
• The voltage of the server reached the
non-critical voltage threshold.
• A fan has been detected to be running at
low speed.
• The power supply has a critical error.
• The power supply is not connected to
the power.
The server is off or the server is on and is
working correctly.
Action
Check system logs or internal error LEDs to
identify the failed part.
None.