7) Move the control switch to the "ON" position (1 short beep occurs, then 3 seconds later
1 long beep occurs). Replace the front panel. To avoid excessive foaming in the water
tank, there is a 1 minute delay before circulation begins. After approximately 30 minutes
of circulation, the icemaker performs 3 rinse cycles.
8) When the control board starts beeping (5 beep sequence), remove the front panel.
Move the control switch to the "OFF" position.
9) In bad or severe water conditions, turn off the power supply, then remove, clean
(cleaning solution = 5 oz. Hoshizaki "Scale Away" per gallon of warm water), rinse, and
replace the cube guide, float switch, water supply tubes, spray tubes, and spray guides;
turn on the power supply when complete. Otherwise, continue to step 10.
Sanitizing
10) Confirm the mode switch is in the "CLEAN" position, then move the control switch to the
"ON" position (1 short beep occurs, then 3 seconds later 1 long beep occurs).
Replace the front panel. The water tank drains and then fills.
11) When the control board starts beeping (2 beep sequence), remove the front panel.
Move the control switch to the "OFF" position.
12) Remove the front insulation panel, then pour 7.5% sodium hypochlorite solution
(chlorine bleach) into the water tank. See table below for amount. Replace the front
insulation panel.
IMPORTANT! Use regular bleach with no additives. Using a bleach with additives
causes excessive foaming during sanitizing, reducing the effectiveness of
sanitizing.
13) Move the control switch to the "ON" position (1 short beep occurs, then 3 seconds later
1 long beep occurs). Replace the front panel. To avoid excessive foaming in the water
tank, there is a 1 minute delay before circulation begins. After approximately 30 minutes
of circulation, the icemaker performs 3 rinse cycles.
14) When the control board starts beeping (5 beep sequence), remove the front panel.
Move the control switch to the "OFF" position.
15) Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly
after cleaning.
16) Move the mode switch to the "ICE" position, then move the control switch to the "ON"
position. Note: If on a dispenser unit, turn on the dispenser unit power supply.
17) Replace all panels in their correct positions.
Model
KML-325/500
KML-700
7.5% Sodium Hypochlorite
Solution (Chlorine Bleach)
0.6 fl. oz. (17 ml)