IKA EUROSTAR 100 control Operating Instructions Manual

IKA EUROSTAR 100 control Operating Instructions Manual

Hide thumbs Also See for EUROSTAR 100 control:

Advertisement

Quick Links

20000003965b
EUROSTAR_092016
IKA
EUROSTAR 60 control
®
IKA
EUROSTAR 100 control
®
Operating instructions
EN

Advertisement

Table of Contents
loading

Summary of Contents for IKA EUROSTAR 100 control

  • Page 1 20000003965b EUROSTAR_092016 EUROSTAR 60 control ® EUROSTAR 100 control ® Operating instructions...
  • Page 2 EUROSTAR Wireless Controller station (WiCo) Fig. 2 Fig. 1 Fig. 3 Fig. 4 K - EUROSTAR 100 control RS 232 Temp. Sensor Fig. 5 Fig. 6 Fig. 7 Fig. 8...
  • Page 3: Table Of Contents

    Drive Error codes Motor protection Warranty Speed – normal operation Accessories Speed – overload operation Permitted IKA ® stirrer tools Output shaft Technical data Speed display Declaration of conformity We declare under our sole responsibility that this product corresponds to the regulations 2014/35/EU, 2006/42/EC, 2014/30/EU and 2011/65/EU and conforms with the standards or standardized documents EN 61010-1, EN 61010-2-051, EN 61326-1, EN 60529 und EN ISO 12100.
  • Page 4: Explication Of Warning Symbols

    • Socket must be earthed (protective ground contact). precautions (e.g. shatter protection). In any case, when using • The voltage stated on the type plate must correspond to the mains critical or hazardous materials in your processes, IKA ® recom- voltage.
  • Page 5 Disposal instructions: • If the instrument is operated too long in overload or if the ambi- • When disposing of the IKA battery pack, please tape over the ® ent temperature is too high, the instrument switches off per- contacts with adhesive tape to prevent short-circuiting due to manently.
  • Page 6: Correct Use

    - In the case of any damage a detailed report must be sent im- mediately (post, rail or forwarder). • Delivery scope: Adapter Adapter - EUROSTAR 60 control or EUROSTAR 100 control stirrer Europe, Switzerland USA, China with a Wireless Controller (WiCo) of the type ordered - An operating instructions...
  • Page 7: Speed - Overload Operation

    Message in the display: Error 4 (see “Error codes” section). Output shaft The clamping chuck and output shaft permit clamping IKA recom- ® For safety reason, the stirrer cover must be pushed back into the mend stirrer tools (see section “Permitted IKA...
  • Page 8: Switching On The Instrument

    - Install the driver automatically, if it is not already installed - Prompt the user to perform a manual installation Securing the stirring shaft protector Open http://www.ika.com/ika/lws/download/usb-driver.zip Diagram (see Fig. 5) Charging the RB 1 battery pack (rechargeable battery) Use a stirring shaft protector (Q), e.g.
  • Page 9: Useful Information

    Return to the previous menu level / reset the torque Rev button: Reversal of the direction of rotation (only the EUROSTAR 100 control) Note: Can be activated only when the station is in stand-by mode. Working screen at the time of delivery: Bluetooth ®...
  • Page 10 - is connected to the power supply unit OS 1.0 via a USB cable 00:00 This symbol indicates that the stirrer is in intermittent mode. - is connected to the EUROSTAR station via the charger contacts. Note: For the EUROSTAR 100 control the symbol changes LIMIT Speed limit:...
  • Page 11 Factory Settings ………………………………..……………………………………..… activated Bluetooth Information Version ………………………………………… yes Operating Mode ……………………………… yes Safe Speed ……………………..……………… yes Max Speed ………………………..….……….. yes Max Torque …………………...……………… yes Interval Run ………………………….………… yes Interval Stop ………………………...………… yes Note:  Only for EUROSTAR 100 control!
  • Page 12: Torque Limit

    Menu (details): Stirring: Speed Limit: Torque Display: The ”Speed Limit” menu allows the user to set the desired maxi- The ”Torque Display” menu allows the user to specify that the mum upper speed limit for the EUROSTAR 60 / 100 control torque is shown in the display.
  • Page 13: Display

    Temperature: Programs: In the ”Temperature” menu the user can specify that the tem- Under menu "Programs", 5 user-defined speed (rpm)-time pro- perature sensor is displayed on the display/working screen. A tick files can be created. In addition, the user could define the intermit- shows that the option is activated.
  • Page 14: Program 1

    View the program in graph: After a program is being edited, press the "Back" button to save the settings. Press the "Back" button again, the screen back to follow screen. Programs Program 1 Program 2 Program 3 Program 4 Program 5 Start Edit Delete...
  • Page 15 Sample for editing the program: PROGRAM 1 PROGRAM 1 Programs Programs Programs Time Interm. Time Interm. hh:mm Mode hh:mm Mode Program 1 Program 1 Program 1 00:00 00:00 Program 2 Program 2 Program 2 Program 3 Program 3 Program 3 Program 4 Program 4 Program 4...
  • Page 16: Safety

    Settings: Safety: Languages: Time Out: The “Languages“ option allows the user to select the desired In the “Time Out“ menu, the user can set a time limit. This time language by turning and pressing the rotary/push knob (B). A tick limit applies if there is a communication failure between the indicates the language that is set for the system.
  • Page 17: Interfaces And Outputs

    1.1). Installation: First, download the latest driver for IKA® devices with USB in- The NAMUR commands and the additional specific IKA ® terface from http://www.ika.com/ika/lws/download/usb-driver.zip mmands serve only as low level commands for communication and install the driver by running the setup file.
  • Page 18: Maintenance And Cleaning

    For cleaning disconnect the main plug! When ordering spare parts, please give: - machine type - manufacturing number, see type plate Use only cleaning agents which have been approved by IKA ® - item and designation of the spare part see www.ika.com, clean IKA ®...
  • Page 19: Error Codes

    - Contact the service department - Send the instrument for repair, including a short description of the fault. Warranty In accordance with IKA ® warranty conditions, the warranty period The warranty does not cover worn out parts, nor does it apply is 24 months.
  • Page 20: Technical Data

    Technical data EUROSTAR 60 control EUROSTAR 100 control EUROSTAR station + Wireless Controller (WiCo) Speed range under nominal load 0 / 30 – 2000 0 / 30 – 1300 Speed adjustment Stepless Speed display TFT / Wireless Controller Speed setting accuracy ±...