Fig. 3: Cable and line entry
1
O-ring
2
Double nipple
3
Seal insert
Pressure nut (with clamping collar)
4
5
Clamping screws of the strain relief
In the state as delivered, the cable and line entry is already screwed in the
terminal box of the valve.
1.
De-energize and depressurize the relevant system part.
2.
Open the terminal box (internal hexagon, wrench size 3)
3.
Remove the outer sheath of the connection line and the insulation of the
individual conductors. Press the wire end ferrules to the individual conductors.
For the stripping lengths, refer to Fig. 4 and Table 9.
Fig. 4: Stripping lengths
5
L1
L2
RE23178-XE-B/10.20, WE6..6X/...XE..., Bosch Rexroth AG
Assembly
1
2
3
4
L4
L3