Fan control in heating thermo - OFF

■ When the room temperature reaches the set temperature during heating operation, the heating thermostat turns OFF.
Fan control in heating thermo - OFF can be selected.
RLH012A503_EN.indd 25
RLH012A503_EN.indd 25
1
Select the Fan control in heating thermo - OFF by
pressing the MENU switch.
2
Select the Fan control by pressing the " or
TIMER)" button.
Initial
Fireplace
display
function
The unit operates at the FAN SPEED set by the remote control.
Heat generated from other heat sources can be circulated in the
room by operating the indoor fan continuously.
The air-conditioner controls the FAN SPEED automatically.
The indoor fan starts and stops the operation at regular intervals
in order to avoid cold draft during heating thermo - OFF.
The indoor fan stops. To use this function additional work is
required, so consult your dealer.
Otherwise, it may take time to return to heating and the heating
capacity may be insufficient.
3
Press the ON/OFF button.
NOTICE
• Once Fan control in heating thermo - OFF is configured, it is stored in the
air-conditioner even if the power source is turned off. To change Fan control in
heating thermo - OFF, set again with the remote control.
EN-25
(TEMP/
Normal
Interval
Stop
function
function