Trouble Conditions; Trouble Acknowledgement; Alarm Memory; Door Chime - Impassa SCW90551-433 User Manual

Self-contained wireless alarm system
Table of Contents

Advertisement

11. Trouble Conditions

When a trouble condition is detected, the Trouble ( ) indicator will turn on and the keypad will beep
every 10 seconds. Press the [#] button to silence the beeps. Press [
The Trouble ( ) indicator will flash. Use the scroll [<][>] keys to view troubles.
Trouble
Alternate
Communicator Trouble
Service Required
(Press [1] for more infor-
mation)
Loss of AC Power
Telephone Line Fault
Failure to
Communicate
Module/Sensor Fault
Module/Sensor Tamper
Module/Sensor Low Bat-
tery
Loss of Time & Date
Blank Display / No
Response
"Panel Response Not
Received" message

12. Trouble Acknowledgement

When the Troubles Inhibit Arming feature is enabled, the Trouble Acknowledgement feature may be
used to acknowledge and override the existing troubles, so the system can be armed. To use this fea-
ture, press
when the keypad displays, "Trouble Acknowledgement." An override event will also be logged, thus
identifying the user. To override open, faulted or tampered zones use the Zone Bypass feature
(
).

13. Alarm Memory

When an alarm occurs, the Alarm Memory message will be displayed. To view which sensor(s) gen-
erated the alarm, press [
in alarm memory. Press [#] to exit. To clear the memory, arm/set and disarm/unset the system.
If an alarm sounded while armed/set, the system will automatically go to alarm memory when you
disarm the system. In this instance, you should proceed with caution, as the intruder may still be
within the building/premises.

14. Door Chime

To turn the door chime function on or off, press and hold the Chime
press [
][4]. The system will sound 3 beeps to indicate the door chime is on, or one long tone to indi-
,
cate that door chime is off.
Indicates SIM Card Lock, 3G Network Trouble, Ethernet Trouble,
Central Station Receiver Trouble, Supervision Trouble, and SMS
Config Trouble. Press [<][>] to scroll through individual troubles.
Indicates Low Battery, System Trouble, System Tamper or RF Jam
detected.
If the building and/or neighbourhood has lost electrical power, the
system will continue to operate on battery power for several hours.
The system has detected that the telephone line is disconnected.
The system attempted to communicate with the monitoring station
but failed. This may be due to a telephone line fault.
The system is experiencing difficulties with one or more module/
sensor on the system. Continue to press [5] to navigate through the
zone, keypad, and siren fault menus.
The system has detected a tamper condition with one or more mod-
ule/sensor on the system. Continue to press
the zone, keypad, and siren tamper menus.
The system has detected a low battery condition with one or more
module/sensor on the system. Continue to press
zone(s), wireless key(s), keypad(s), siren(s) and prox tag(s).
If complete power was lost (AC and Battery), the time and date will
need to be re-programmed. Press
Keypad battery may have discharged beyond the usable level.
The keypad has lost wireless communication with the panel. Occa-
sional display of this message may be caused by local radio fre-
quency interference.
to enter the Trouble menu. Scroll
][3]. For the system keypad use the scroll [<][>] buttons to view the sensors
,
Comments
[6]
to navigate through
[7]
[
]
,
.
8
][2] to view the trouble condition.
,
Call for service.
For Ethernet Trouble
check LAN connec-
tions.
Call for service.
Check AC connection.
Call for service.
Call for service.
Call for service.
Call for service.
Call for service.
See section 22.1 Siren
and Keypad Display
to display the
Test. Call for service.
Reprogram Time &
Date.
Replace battery (call for
service if trouble not
cleared).
If trouble persists, call
for service.
left or right and press
button for 2 seconds or
Action
or

Advertisement

Table of Contents
loading