OPERATION
To switch to propane:
l Open the cylinder valve on the LP gas cylinder to start
the flow of propane.
l Rotate the fuel selector switch fully counterclockwise for
PROPANE.
l Turn off the flow of gasoline.
HIGH ALTITUDE OPERATION
Engine power is reduced the higher you operate above sea
level. Output will be reduced approximately 3.5% for every
1,000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at altitudes
over 5,000 ft. (1524 m). Operation without this adjustment
will cause decreased performance, increased fuel consump-
tion, and increased emissions.
NOTICE
DO NOT operate the generator at alti-
tudes below 2,000 ft. (762 m) with the high altitude kit
installed. Engine damage may occur.
High Altitude
Carburetor Kit
DATA CENTER
See Figure 15.
Push the mode button to cycle through the data display
modes.
Voltage: Displays current voltage output.
Frequency (Hz): Displays power output frequency in Hertz.
Lifetime Hours: Displays the lifetime run hours.
Fuel Level: Indicates how much gasoline remains in the
fuel tank.
Run Time/Maintenance: Displays current run time. Resets
to zero when shut down. Maintenance reminder displayed
when required.
Maintenance Codes:
  P25 – Change engine oil
  P50 – Clean air filter, Change engine oil
  P100 – Change engine oil, clean air filter, replace fuel filter
BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated running
watts during the first five hours of operation.
Use supplied oil until first recommend oil change. Do not
use full synthetic oil during break in period. Full synthetic oil
may prevent proper breaking and seating of the piston rings.
Vary the load occasionally to allow stator windings to heat
and cool and help seat the piston rings.
Part# 518527-01
FIG. 14
A
A - Gasoline position
B - Propane position
C - Fuel selector switch
FIG. 15
A
C
E
A - Voltage
B - Power output
C - Lifetime hours
D - Fuel level
E - Run time/maintenance reminder
F - Mode button
BEFORE STARTING THE GENERATOR
Verify that:
l The generator is placed in a safe, appropriate location.
l The generator is on a dry, flat, and level surface.
l Oil and fuel levels are within safe operating range.
l All loads are disconnected from the control panel recep-
tacles.
l The ECO mode switch is in the OFF position.
B
C
F
B
D
English | 19