Omntec PROTEUS Mini-Me RD7CTS Programming Instructions

Remote display

Advertisement

Quick Links

 
 
 
RD7CTS Remote Display
 
 
1. Powering On 
For installation instructions, refer to 
document DI00028 (PROTEUS RD7CTS 
Installation Instructions). 
If plugging into an OMNTEC OEL8000II's RS‐
232 port, make sure it is connected to 
COMM2 or COMM3 of the motherboard 
and set for Remote Mode. 
When the RD7CTS is powered on and not 
connected to an ATG, the display will show 
the screen below.  (See Figure 1.0) 
 
After connecting to an ATG, the RD7CTS will 
update its information to show the correct 
time and date as well as Inventory.  (See 
Figure 2.0) 
 
 
 
Figure 1.0 
Figure 2.0 
OMNTEC Mfg., Inc., 2420 Pond Road, Ronkonkoma, NY 11779 
Phone (631) 981‐2001  Fax (631) 981‐2007  www.OMNTEC.com 
File Name: DP00028 rev2050.docx  Page 1 of 2  Rev Date: 12‐10‐2020 
2. Navigating to Setup 
From the System Status Menu, press HELP 
MENU. (See Figure 3.0) 
 
In HELP MENU press SETUP.   Default 
password is "000000" (See Figure 4.0) 
 
 
Below is the SETUP MENU. (See Figure 5.0) 
 
 
 
 
 
 
 
 
Programming Instructions 
Figure 3.0 
Figure 4.0 
Figure 5.0 
 
 

Advertisement

loading

Summary of Contents for Omntec PROTEUS Mini-Me RD7CTS

  • Page 1       Programming Instructions  RD7CTS Remote Display       1. Powering On  2. Navigating to Setup  For installation instructions, refer to  From the System Status Menu, press HELP  document DI00028 (PROTEUS RD7CTS  MENU. (See Figure 3.0)  Installation Instructions).  If plugging into an OMNTEC OEL8000II’s RS‐ 232 port, make sure it is connected to  COMM2 or COMM3 of the motherboard  and set for Remote Mode.  When the RD7CTS is powered on and not  connected to an ATG, the display will show    the screen below.  (See Figure 1.0)  Figure 3.0    In HELP MENU press SETUP.   Default  password is “000000” (See Figure 4.0)      Figure 1.0  After connecting to an ATG, the RD7CTS will  update its information to show the correct    time and date as well as Inventory.  (See  Figure 4.0    Figure 2.0) ...
  • Page 2 Use the info page as a guide to program  these parameters.  (See Figure 6.0)    Figure 8.0      6. Unit Mode  Figure 6.0    When a single Mini‐Me is connected via RS‐ 4. Changing Baud Rate  232, the unit mode should be set for  To change the Baud Rate, select Remote  Transmitter.  When multiple Mini‐Me’s are  Communications Settings.  The baud rate  connected via RS‐232‐422 extender, the  and other options will cycle through preset  farthest Mini‐Me from the ATG should be  values each time you press Change.  Match  set for Transmitter and each additional  these to the main ATG.  Selecting View  Mini‐Me in between should be set for  Polling Data will allow the user to view  Receiver.  When using RS‐485, all Mini‐Me’s  communications between the Mini‐Me and  should be set for Receiver.  (See Figure 9.0)  main ATG.  (See Figure 7.0)      Figure 9.0      Figure 7.0  **Important:  Always press SAVE when finished.**  OMNTEC Mfg., Inc., 2420 Pond Road, Ronkonkoma, NY 11779  Phone (631) 981‐2001  Fax (631) 981‐2007  www.OMNTEC.com  File Name: DP00028 rev2050.docx  Page 2 of 2  Rev Date: 12‐10‐2020 ...