RD7CTS Remote Display
3. Changing Parameters
Pressing the information button will show
the user what each parameter will change
within the SETUP MENU. Most parameters
can be changed to the user's preference.
Use the info page as a guide to program
these parameters. (See Figure 6.0)
4. Changing Baud Rate
To change the Baud Rate, select Remote
Communications Settings. The baud rate
and other options will cycle through preset
values each time you press Change. Match
these to the main ATG. Selecting View
Polling Data will allow the user to view
communications between the Mini‐Me and
main ATG. (See Figure 7.0)
Figure 6.0
Figure 7.0
OMNTEC Mfg., Inc., 2420 Pond Road, Ronkonkoma, NY 11779
Phone (631) 981‐2001 Fax (631) 981‐2007 www.OMNTEC.com
File Name: DP00028 rev2050.docx Page 2 of 2 Rev Date: 12‐10‐2020
5. Changing Tank Colors & Orientation
Select Tank Colors + Orientation to choose
different colors for each tank. The user may
also choose to view the tank profile as
horizontal or vertical. (See Figure 8.0)
When a single Mini‐Me is connected via RS‐
232, the unit mode should be set for
Transmitter. When multiple Mini‐Me's are
connected via RS‐232‐422 extender, the
farthest Mini‐Me from the ATG should be
set for Transmitter and each additional
Mini‐Me in between should be set for
Receiver. When using RS‐485, all Mini‐Me's
should be set for Receiver. (See Figure 9.0)
**Important: Always press SAVE when finished.**
Programming Instructions
Figure 8.0
6. Unit Mode
Figure 9.0