Mounting
6 7 3
6 7 4
28 | EN
Inserting a sealing insert
Using a sealing insert, the standard flush mounted boxes can be made
airtight at a later stage when mounting the devices.
Fig 25: Inserting a sealing insert
1. Screw the device screws out of the flush-mounted box.
2. Pierce the sealing insert with the cables.
3. Insert the sealing insert in the flush-mounted box.
4. Connect the device with cables and insert it in the sealing insert.
5. Fasten the sealing insert and the device using the device screws.
Mounting a plaster compensation ring
The compensation ring can be used to compensate for an offset of 10 or
20 mm between the top edge of the flush-mounted box and the wall or
plaster surface.
Fig 26: Mounting a plaster compensation ring
1. Screw the device screws out of the flush-mounted box.
OBO Bettermann