Electric fireplace with mounting bracket kit for adjustable installation

Advertisement

Quick Links

TM/MC
GY
GY
GY
GY

Advertisement

Table of Contents
loading

Summary of Contents for Kennedy II Commercial Series

  • Page 1 TM/MC...
  • Page 2 Page 3 07.23.2023...
  • Page 3: Listing Approvals

    Dimensions PRODUCT DIMENSIONS CARTON DIMENSIONS Model No. F/F’ Width x Depth x Height JR-42S / EF-WM502 42” 11.8” 1.3” 16” 44.4” 62.99" W X 9.45” D X 24.80" H 18.3” 4.6” 47.0” / EF-WM502 GY 119.4cm 106.7cm 30cm 3.3cm 40.6cm 112.8cm 160cm W X 24cm D X 63cm H 46.5cm 46.5cm...
  • Page 4 07.23.2023...
  • Page 5 Apps Smart Life app Smart Life Available voice control for Alexa and Google. Scan the QR codes bellow. Alexa “Hey Google” 07.23.2023...
  • Page 6 07.23.2023...
  • Page 7 07.23.2023...
  • Page 8 07.23.2023...
  • Page 9 Option 1: Hanging the Appliance on the Wall NOTE: It is strongly recommended that the mounting bracket be screwed into the wall studs where possible. If the wall studs cannot be used, ensure that the supplied plastic anchors are used to affix the bracket to the wall and the bracket is adequately secured 07.23.2023...
  • Page 10 Option 2: Recessing the Appliance Flush into the Wall NOTE: The slim design of our units allow 07.23.2023...
  • Page 11 47”/119.38cm 18.3”/46.48cm 4.6”/11.68cm 45.4”/115.32cm 17”/43.18cm 4.6”/11.68cm EF-WM502 EF-WM502 GY 55”/139.7cm 18.3”/46.48cm 4.6”/11.68cm 53.4”/135.64cm 17”/43.18cm 4.6”/11.68cm EF-WM503 EF-WM503 GY 65”/165.1cm 18.3”/46.48cm 4.6”/11.68cm 63.4”/161.04cm 17”/43.18cm 4.6”/11.68cm EF-WM504 EF-WM504 GY 77”/195.58cm 18.3”/46.48cm 4.6”/11.68cm 75.4”/191.52cm 17”/43.18cm 4.6”/11.68cm EF-WM505 EF-WM505 GY 07.23.2023...
  • Page 12 Unscrew and remove power cord. 07.23.2023...
  • Page 13 Wall Thermostat Wiring (24AWG) 07.23.2023...
  • Page 14 Front Glass Removal Crystal Embers and Wood Logs Installation 07.23.2023...
  • Page 15 Ensure steps 1-2 in the"Main Power Switch"procedure are first followed. 2. Press the “ button to turn on/off the fireplace; If turn on (indicate "ON"), the Red, blue and yellow flame (F4), ember bed (E3) LEDs at the brightest level. Press again, the heater is in OFF status indicate "OF", goes off after 5 seconds.
  • Page 16 3. Reset the Fireplace by pressing and holding the flame button for 5 seconds, then release. 4. A connecting progress screen will show network scanning is active until the device is added succcesfully. The Kennedy Fireplace control screen will now be active. 4. Check for Firmware Update 5.
  • Page 17: Voice Control

    Voice Control • Available for Alexa and Google Assistant, you can use voice commands to control many features of the fireplace. Install the Alexa app and Google Assistant first and follow the steps below to use voice control. • IT IS IMPORTANT TO USE THE EXACT PHRASES AS VARIATIONS MAY NOT WORK. •...
  • Page 18 Multi-functional Operating with Remote Control Turning ON/OFF the appliance: Ensure steps 1-2 in the"Main Power Switch"procedure are first followed. Changing LED options: . (   ,  Note: Steps 2- can be done independently. Page 18 07.15.23...
  • Page 19: Maintenance

    Remote Control Specification Maintenance WARNING Storage Instructions Page 19 07.15.23...
  • Page 20 Wiring Diagram: Standard Model WARNING TOUCH KEY RECEIVER TEMP SENSOR 120V ADPTER T-IN TRAN.-I TEMP MOOD1 R-N1 P-N1 M-N1 MOOD2 F-N1 F-N2 FLAME EMBER MOTOR1 HEATER FLAME MOTOR Page 20 07.15.23...
  • Page 21: Replacement Parts

    Replacement Parts WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. To order parts, contact customercare@jrhome.com FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
  • Page 22 Page 22 07.15.23...
  • Page 23 TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE. Symptom Potential Cause Solution Abnormal noise From heater assembly (item 7) Blower assembly has a defect that is causing noise during high speed rotation.
  • Page 24: Troubleshooting

    Troubleshooting Symptom Potential Cause Solution wire loosing necessary light is not glowing or dimming or wire loosing necessary out or wire loosing necessary Main circuit board burnt out or Inspect the Main circuit board and re- wire loosing place if necessary No warm air coming Room temperature is higher Reset temperature setting...
  • Page 25 2 Years 2 Annees IMPORTANT For questions, concerns or problems with our product please Si vous éprouvez des dicultés, ou si vous avez des questions ou des email our customer service department: préoccupations, prière de faire parvenir un courriel à notre Service à la clientèle customercare@jrhome.com customercare@jrhome.com DATED PROOF OF PURCHASE REQUIRED FOR WARRANTY SERVICE...