Accessories

4.1 Brine Circuit Manifold

The brine circuit manifold merges the individual collector loops
of the heat source system into a single main pipe which is con-
nected to the heat pump. Integrated ball valves allow the indi-
vidual brine circuits to be shut off for de-aeration purposes.

4.2 Brine Controller

If required by the authorities, a low-pressure brine controller
can be installed in the device. In this case, the connection lo-
cated upstream from the brine expansion vessel provided for
this purpose is to be used.

4.3 Remote control

A remote control adds convenience and is available as a special
accessory. Operation and menu navigation are identical to
those of the heat pump manager. Connection takes place via an
interface (special accessories) with RJ 12 Western plug.
NOTE
In the case of heating controllers with a removable operating
element, this can also be used directly as a remote control.
4.4 Building management
technology
The heat pump manager can be connected to a building man-
agement system network via supplementation of the relevant
interface plug-in card. The supplementary installation instruc-
tions of the interface card must be consulted regarding the
exact connection and parameterisation of the interface.
The following network connections can be made on the heat
pump manager:
Modbus
EIB, KNX
Ethernet
CAUTION!
If the heat pump or circulating pumps are controlled
externally, an flow rate switch is required to prevent the
compressor from being switched on when there is no volume
flow.
EN-4
5

Transport

A lift truck is suited for transporting the unit on a level surface.
Carrying straps may be used if the heat pump needs to be
transported on an uneven surface or carried up or down stairs.
These straps can be passed directly underneath the pallet.
CAUTION!
The heat pump is not secured to the pallet.
CAUTION!
The heat pump must not be tilted more than 45° (in any
direction).
Use the holes provided in the sides of the frame to lift the unit
without the pallet. The side panel assemblies must be removed
for this purpose. Any commercially available length of pipe can
be used as a carrying aid.
CAUTION!
Do not use the holes in the panel assemblies for lifting the
device!
452231.66.34a · FD 0201
SIK 6TES - SIK 14TES
www.glendimplex.de