peerless-AV KIL640-EUK Installation Instructions Manual

Black/silver
Hide thumbs Also See for KIL640-EUK:

Advertisement

Quick Links

BLACK
KIL640-EUK
KIL642-EUK
KIL646-EUK
KIL647-EUK
KIL648-EUK
KIL655-EUK
ENG
SILVER
KIL640-S-EUK
KIL642-S-EUK
KIL646-S-EUK
KIL647-S-EUK
KIL648-S-EUK
KIL655-S-EUK
1
2015-07-23
#:150-9057-1

Advertisement

loading

Summary of Contents for peerless-AV KIL640-EUK

  • Page 1 BLACK SILVER KIL640-EUK KIL640-S-EUK KIL642-EUK KIL642-S-EUK KIL646-EUK KIL646-S-EUK KIL647-EUK KIL647-S-EUK KIL648-EUK KIL648-S-EUK KIL655-EUK KIL655-S-EUK 2015-07-23 #:150-9057-1...
  • Page 2 WARNING ENG - Do not begin to install product until you have read and understood the instructions and warnings contained in this user guide. This product is designed to be installed on wood stud, solid concrete or cinder block walls. Hardware is included for wood stud, solid concrete and cinder block installation. Before installing make sure the supporting surface will support the combined load of the equipment and hardware.
  • Page 3 Tools Needed for Assembly. ENG To properly tighten screws: Tighten until screw head makes contact, then tighten another 1/2 turn. Do not overtighten screws. +1/2 5/32" (4mm) 3/8" (10mm) 5/16" (8mm) 2015-07-23 #:150-9057-1...
  • Page 4 Parts (Before beginning, make sure you have all parts shown below). A ( 1 ) B (4) C (4) kiosk M5 x 12 mm M5 x 25 mm D (4) E (4) M6 x 12 mm M6 x 25 mm F (4) G (4) M8 x 12 mm...
  • Page 5 J ( 2 ) 2015-07-23 #:150-9057-1...
  • Page 6 Wood stud wall. Concrete/Cinder block. 3a-1 3a-1 Use stud fi nder to locate and mark stud center lines. 2015-07-23 #:150-9057-1...
  • Page 7 3a-2 Level wallplate. Mark mounting holes on stud center lines. 2015-07-23 #:150-9057-1...
  • Page 8 3a-3 2.5" (64mm) 5/32" 5/32" (4mm) (4mm) Drill mounting holes into supporting surface (2.5" (64 mm) minimum depth required). Mounting hole must center on stud. 3a-4 3/8" (10mm) M (4) 2015-07-23 #:150-9057-1...
  • Page 9 WARNING ENG • When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum compressive strength of 2000 psi. • When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet ASTM C-90 specifi...
  • Page 10 3b-2 2.5" (64mm) 5/16" 5/16" (8mm) (8mm) Drill mounting holes into supporting surface (2.5" (64 mm) minimum depth required). Do not drill into mortar joints. 3b-3 Insert anchor fl ush to concrete. 2015-07-23 #:150-9057-1...
  • Page 11 3b-4 3/8" Maximum 80 in. • lb (9 N.M.). (10mm) Level wallplate. Install using concrete anchors and wood screws provided. M (4) 2015-07-23 #:150-9057-1...
  • Page 12 Center adapter brackets vertically on back of screen. Screws must get at least three full turns and fi t snug. ENG Use of spacers is OPTIONAL. H (4) G(4) B (4) D (4) H (4) H (4) I (4) E (4) F (4) G (4) H (4)
  • Page 13 2015-07-23 #:150-9057-1...
  • Page 14 5-2a 5-2b Note: Mounting Arm swings out to access adapter brackets and behind display 2015-07-23 #:150-9057-1...
  • Page 15 Plug in fan power cord. For use with two pin sockets remove plug adapter 2015-07-23 #:150-9057-1...
  • Page 16: Limited Five-Year Warranty

    This warranty gives specifi c legal rights, and you may also have other rights which vary from state to state. Patent Pending Peerless-AV Peerless-AV Europe Peerless-AV de Mexico 2300 White Oak Circle Unit 3 Watford Interchange, Ave de las Industrias 413...