Table of Contents Safety Instructions Model Indication and How to Order Summary of Product parts Definition and terminology Mounting and Installation Installation Wiring Pressure Setting Outline of Settings Initial Setting 3 Step Setting Mode Simple Setting Mode Function Selection Mode Function selection mode Default setting F 0 Units selection function...
Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
Page 4
Safety Instructions Caution 1.The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Page 5
Operator ♦This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. ♦Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
Page 6
Caution ■Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result. ■After maintenance is complete, perform appropriate functional inspections and leak tests. Stop operation if the equipment does not function properly or there is a leakage of fluid. When leakage occurs from parts other than the piping, the product might be faulty.
Page 7
●Product handling ∗Installation •Tighten to the specified tightening torque. If the tightening torque is exceeded the mounting screws and brackets may be broken. If the tightening torque is insufficient, the product can be displaced and loosen the mounting screws. •Be sure to ground terminal FG when using a commercially available switch-mode power supply. •Do not drop, hit or apply shock to the product.
Page 8
•Do not use a load which generates surge voltage. When a surge-generating load such as a relay or solenoid is driven directly, use a product with a built-in surge absorbing element. •The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes in the system.
Model Indication and How to Order ○Accessories/Part numbers If an option is required independently, order with the following part numbers. Items Part No. Remarks Bracket Self tapping screws: Nominal size 3 x 8L (2 pcs.) ZS-46-A1 Panel mount adapter ZS-46-B Panel mount adapter + Front protective cover ZS-46-D Front protective cover...
Summary of Product parts ○Names of individual parts Operation light: Displays the switch operating condition. LCD display: Displays the current status of pressure, setting mode, selected display units and error code. 4 types of display can be selected for the main display: Single colour of constant red or green; or switching from red to green or green to red corresponding to the output.
■Definition and terminology Term Definition Performs pressure setting automatically by detecting the increase and decrease in pressure. For example, if this function is used for a suction test, Auto-preset the pressure setting will be completed by performing suction and release of the workpiece.
Page 12
Term Definition Fine adjustment mode Refer to "Display value fine adjustment (function)". Abbreviation of full span and full scale; difference between the minimum and maximum rated pressure values. means the maximum fluctuation range of F.S. the product rated value. (full span/full scale) For example, when the rated pressure range is -0.100 to 1.000 [MPa]: F.S.
Page 13
Term Definition Shows the maximum pressure from when the power was supplied to the Peak value display (mode) current time. Operating mode in which the digital display turns off and power consumption Power saving mode is reduced. The set pressure value that determines the point at which the product turns Pressure setting ON and OFF.
Mounting and Installation ■Installation ○Mounting with bracket ●Mount the bracket to the body with mounting screws (Self tapping screws: Nominal size 3 x 8L (2 pcs)), then set the body to the specified position. ∗: Tighten the bracket mounting screws to a torque of 0.5±0.05 N•m. Self tapping screws are used, and should not be re-used several times.
Page 15
○Mounting with panel mount adapter ●Mount part (a) to the front of the body and fix it. Then insert the body with (a) into the panel until (a) comes into contact with the panel front surface. Next, mount part (b) to the body from the rear and insert it until (b) comes into contact with the panel for fixing.
■Wiring ○Wiring connections ●Connections should be made with the power supply turned off. ●Use a separate route for the product wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise. ●If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal.
Page 17
○Attaching the connector to the lead wire ●Sensor wire is stripped as shown in the right figure. (Refer to the table below for correspondence between connector and electrical wire gauge.) Lead wire table AWG No. Conductor size (mm Overall diameter (mm) Colour of cover SMC product No.
Page 18
○Internal circuit and wiring example NPN (2 outputs) + copy function setting PNP (2 outputs) + copy function setting NPN (2 outputs) + analogue voltage output setting NPN (2 outputs) + analogue current output setting PNP (2 outputs) + analogue voltage output setting PNP (2 outputs) + analogue current output setting -17- No.PS※※-OMW0014-B...
Pressure Setting Default settings When the pressure exceeds the set value, the switch will be turned on. When the pressure falls below the set value by the amount of hysteresis or more, the switch will be turned off. The default setting is that the output is turned ON at -50.5 kPa when the pressure range of the connected sensor is vacuum pressure.
Outline of Settings Power is supplied The product code is displayed for approximately 3 sec. after supplying power. After that, measurement mode is displayed. ∗: Within approximately 0.2 second after power-on, the switch starts. [Initial Setting] (Refer to page 21) Set the pressure range, display unit and switch output NPN/PNP specification.
Initial Setting Set the pressure range, display unit and NPN/PNP output specifications. Measurement mode Press the SET button between 3 and 5 seconds. [F 0] Display the switching function of the pressure range, display unit and switch output specifications. Press the SET button. Move on to pressure range setting.
Page 23
Setting of the lower limit of the additional rated range Press the UP or DOWN button to change the value. Press the button continuously to keep changing the value. Set the value that is required to be displayed when the sensor input signal is 0%. The setting range is -1500 to 1500 digit.
Page 24
Switching setting of switch output NPN/PNP specifications The switch output of this product can be switched to NPN or PNP output in accordance with the user device construction. Press the UP or DOWN button to select switch output specification. Press the SET button to set. Return to function selection mode.
3 Step Setting Mode 3 step setting mode In this mode, the set values can be input in just 3 steps. Use this mode if the product is to be used straight away, after changing only the set values. (The current pressure value is displayed on the main display.) <Operation>...
Page 26
The product turns on within a set pressure range (OUT1: from P1L to P1H, OUT2: from P2L to P2H) during window comparator mode. Set P1L/P2L, the lower limit of the switch operation, and P1H/P2H, the upper limit of the switch operation and WH1/WH2 (hysteresis) following the instructions given on page 24. (When reversed output is selected, the sub display (left) shows [n1L]/[n2L] and [n1H]/[n2H].) Please refer to the "List of output modes"...
Simple Setting Mode <Operation> [Simple setting mode (hysteresis mode) In the simple setting mode, the set value, hysteresis and delay time can be changed while checking the current pressure value (main display). (1) Press and hold the SET button between 1 and 3 seconds in measurement mode. [SEt] is displayed on the main display.
Page 28
In the window comparator mode, set P1L/P2L, the lower limit of the switch operation, and P1H/P2H, the upper limit of the switch operation, WH1/WH2 (hysteresis) and dt1/dt2 (delay time) following the instructions given on page 26. (When reversed output is selected, the sub display (left) shows [n1L]/[n2L] and [n1H]/[n2H].) Please refer to the "List of output modes"...
Function Selection Mode ■Function selection mode In measurement mode, press the SET button between 3 and 5 seconds, to display [F 0]. Select to display the function to be changed [F□□]. Press and hold the SET button for 2 seconds or longer in function selection mode to return to measurement mode.
Page 30
•[F 2] Setting of OUT2 Page Item Explanation Default setting Either hysteresis mode, window comparator mode, error output Output mode Hysteresis mode or switch output OFF can be selected. Reversed output Selects which type of switch output is used, normal or reversed. Normal output Pressure setting Sets the ON and OFF point of the switch output.
■[F 0] Switching function of pressure range, display unit and switch output specifications Pressure range setting Pressure range that matches with the connected sensor can be selected. In addition, the required range can be set and displayed. (Additional range) •Relation between analog input and digital display Set value 0.002 0 kPa...
Page 32
<Operation> Press the UP or DOWN button in function selection mode to display [F 0]. Press the SET button. Move on to pressure range setting. Pressure range setting Press the UP or DOWN button to select pressure range. [USEr] is selected. Press the SET button to move on to the setting of the minimum unit of the additional range.
Page 33
Setting of the upper limit of the additional rated range Press the UP or DOWN button to change the value. Press the button continuously to keep changing the value. Set the value that is required to be displayed when the sensor input signal is 100%. The setting range is -1500 to 1500 digit.
Page 34
●Settable range of the additional range <Minimum settable unit [Udot]: "0.001", "0.01", "0.1", "1"> <Minimum settable unit [Udot]: "0.002", "0.02", "0.2", "2"> ∗: When pressure range, minimum unit/lower limit/upper limit of additional range is changed, setting below will be initialized and cleared.
■[F 1] Setting of OUT1 Set the output mode of OUT1. Output turns on when the pressure is greater than the set value. The default setting is to turn on the product when the pressure reaches the center of the atmospheric pressure and upper limit of the rated pressure range.
Page 36
Hysteresis setting Set the pressure referring to the setting method on page 24. Hysteresis mode: [H_1] Window comparator mode: [WH1] The snap shot function can be used. (Refer to page 66) Press the SET button to set. Move on to delay time setting. Delay time setting Set the delay time referring to the setting method on page 26.
Page 37
●List of output modes If the point at which the switch output changes is outside of the set pressure range due to the selection of normal or reversed output, the hysteresis value is automatically adjusted. ∗1: The applicable errors are "Er6 to 9", "o.r." and "Er1 or 2" (excluding the error output). (Er7 may not be output depending on the status of the data) ∗: The figure above shows an operation at OUT 1.
■[F 2] Setting of OUT2 Set the output mode of OUT2. Output turns on when the pressure is greater than the set value. The default setting is to turn on the product when the pressure reaches the center of the atmospheric pressure and upper limit of the rated pressure range.
Page 39
Hysteresis setting Set the pressure referring to the setting method on page 24. Hysteresis mode: [H_2] Window comparator mode: [WH2] The snap shot function can be used. (Refer to page 66) Press the SET button to set. Move on to delay time setting. Delay time setting Set the delay time referring to the setting method on...
■[F 3] Digital filter setting The Digital filter can be selected to filter the pressure measurement. Output chattering or flicker in the measurement mode display can be reduced by setting the digital filter. <Operation> Press the UP or DOWN button in function selection mode to display [F 3]. Press the SET button.
■[F 4] Auto-preset function This function will automatically calculate and set the optimum pressure based on the actual operating condition, when hysteresis mode has been selected. <Operation> Press the UP or DOWN button in function selection mode to display [F 4]. Press the SET button.
Page 42
●Auto-preset When auto-preset is selected in function selection mode, the set value can be calculated and memorized from the measured pressure. Repeating the suction and release of the workpiece to be set for several times will automatically optimize the set value. (1) Selection of auto-preset OUT1 mode Press the SET button in measurement mode to display [AP1 REdY].
■[F 5] FUNC terminal setting When the product with analog output/auto shift input function is used, the FUNC terminal setting can be selected. Analog output: Outputs proportional output according to the applied pressure. Auto-shift: The display indicates the change of relative flow from the reference value. Auto-shift zero: The display is set to zero when the signal is input, and therefore the display indicates the change of relative flow from the reference value.
Page 44
Setting of analogue free span function Press the button to select the analogue free span function. [oFF] not used [on] is enabled Press the SET Press the SET button to set. button to set. Return to Move on to set function value.
Page 45
Setting of effective output Press the UP or DOWN button to select the effective output. Press the SET Return to function button to set. selection mode. [F 5] FUNC terminal setting completed -44- No.PS※※-OMW0014-B...
Page 46
Conditions and explanations for auto-shift function •Maintain a constant pressure for 5 ms or longer from the end of the auto-shift input signal. •The sub screen displays "ASin ooo" for approximately 1 second during auto-shift input, and the pressure value is stored as the corrective value "C_5". •With the corrected value stored, the set value is compensated.
■[F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value. Pressure can be adjusted in the following range of ±5%R.D. <Operation> Press the UP or DOWN button in function selection mode to display [F 6]. Press the SET button.
■[F10] Sub display setting Change the display style of the sub display. Detailed set contents are shown in the pages from 48. <Operation> Press the UP or DOWN button in function selection mode to display [F10]. Press the SET button. Move on to sub display setting.
Page 49
<Sub display> •Standard The Standard display function displays the items and values on the sub display. The displayed item varies depending on the setting of the output mode. Select the displayed items by pressing the UP or DOWN button in measurement mode. (Hysteresis mode, error output, switch output off) (Window comparator mode) -48-...
Page 50
•2 value display The 2 value display function displays the items listed below on the right and left side of the sub display. List of items for selection Sub display Item Details Remarks Left side Right side When hysteresis mode is ○...
Page 51
Table showing the output mode and output form when Md1 and Md2 are selected. Output mode Output style Display style Normal output Hysteresis mode Reversed output Normal output Window comparator mode Reversed output Error output Normal/Reversed output Switch output off When using the 2 value display function, 3 step setting is not available for the display.
Page 52
•Level bar display The Level bar display is a function used to visualize the pressure and the ON area for the switch output on the sub display. The display style varies depending on the setting of the output mode. (In hysteresis mode or window comparator mode) The threshold bar displaying the switch output ON area is displayed according to the table below, using the output mode.
Page 53
During an error output or when the switch output setting is OFF, the pressure value meter at the atmospheric pressure is displayed according to the table below. Rated range Display at atmospheric pressure Other than compound pressure Compound pressure •Character string display The Character string display function will display the specified characters on the sub display (right).
■[F11] Display resolution setting This function is to change the pressure display resolution. The flicker of the display can be reduced. <Operation> Press the UP or DOWN button in function selection mode to display [F11]. Press the SET button. Move on to display resolution setting. Display resolution setting Press the UP or DOWN button to select the display resolution.
■[F80] Power saving mode Power saving mode can be selected. When selected and no buttons are pressed for 30 seconds, the product will shift to power saving mode. <Operation> Press the UP or DOWN button in function selection mode to display [F80]. Press the SET button.
■[F81] Security code The security code can be turned on or off and the security code can be changed when unlocked. <Operation> Press the UP or DOWN button in function selection mode to display [F81]. Press the SET button. Move on to security code. Security code Press the UP or DOWN button to select the setting of security code.
Page 57
Security code changing Press the UP or DOWN button to input the ∗ changed security code on the main display. For instructions on how to enter the security code, refer to "How to input and change the security code" on page 69. After entry, the changed security code will flash by pressing the SET button for 1 second.
■[F82] Input of line name Function to display the specified character string on the sub display. To display in the measurement mode, select 2 value display [dUAL] or character string display [LinE] using the setting on [F10] Sub display setting. <Operation>...
●Special function setting ■[F90] Setting of all functions All functions can be set in turn. <Operation> Press the UP or DOWN button in function selection mode to display [F90]. Press the SET button. Move on to setting of all functions. Setting of all functions Press the UP or DOWN button to select all functions.
Page 60
●Setting of each function Order Function Pressure range setting Display unit selection Switching setting of switch output NPN/PNP specifications Output mode setting of OUT1 Reversed output setting of OUT1 Pressure setting of OUT1 Hysteresis setting of OUT1 Delay time setting of OUT1 Display colour setting Output mode setting of OUT2 Reversed output setting of OUT2...
■[F96] Input signal check The sensor input signal (1 to 5 V or 4 to 20 mA) and the external input signal can be checked. <Operation> Press the UP or DOWN button in function selection mode to display [F96]. Press the SET button. Move on to input signal check.
■[F97] Selection of copy function The set values can be copied. The set values of pressure and functions can be copied. When the input, output and unit specifications are the same, this function becomes available. The set value can be copied to up to 10 pressure switches simultaneously.
Page 63
Copy ready status Even though the power supply is turned OFF, the copy ready status will be retained. Press the SET button to start copying. The copy source sensor monitor The copy destination sensor monitor Sending/ Main display: Main display: Red Receiving Green •When completed...
■[F98] Output check The switch output or analogue output can be selected for an output check. The output can be turned ON/OFF manually for checking. <Operation> Press the UP or DOWN button in function selection mode to display [F98]. Press the SET button. Move on to output check.
Page 65
OUT2 output check Press the UP or DOWN button to select OUT2 output check. When switching of analogue output is selected for the setting of [F 5] FUNC terminal function Press the SET button to move on to FUNC terminal function setting.
■[F99] Reset to default settings If the product settings are uncertain, the default values can be restored. <Operation> Press the UP or DOWN button in function selection mode to display [F99]. Press the SET button. Move on to reset to default settings. Reset to default settings Press the UP or DOWN button to display [ON], then press the SET and DOWN buttons simultaneously for 5 second or longer.
Other Settings ○Snap shot function The current pressure value can be stored to the switch output ON/OFF set point. When the items of sub display (left) below are selected in 3 step setting mode, simple setting mode or function selection mode ([F 1] Setting of OUT1, [F 2] Setting of OUT2), by pressing the UP and DOWN buttons simultaneously for 1 second or longer, the value of the sub display (right) shows [- - -], and the values corresponding to the current pressure values are automatically displayed.
Page 68
○Key-lock function The key-lock function is used to prevent errors occurring due to unintentional changes of the set values. If the SET button is pressed while the keys are locked, [LoC] is displayed on the sub display (left) for approximately 1 second. (Each setting and peak/bottom values are displayed with UP and DOWN buttons.) <Operation - Without security code input ->...
Page 69
<Operation – With security code input -> •Locking (1) Press the SET button for 5 seconds or longer in measurement mode. When [oPE] is displayed on the main display, release the button. The current setting [LoC] or [UnL] will be displayed on the sub display. (2) Select the key [LoC] with UP or DOWN button, and press the SET button to set.
Page 70
●How to input and change the security code The left most digit starts flashing. Press the UP or DOWN button to select a value. Press the SET button to make the next digit to the right flash. (If the SET button is pressed at the last digit, the first digit will start flashing.) After the setting is complete, press and hold the SET button for 1 second or longer.
Maintenance How to reset the product after a power cut or forcible de-energizing The setting of the product will be retained as it was before a power cut or de-energizing. The output condition is also basically recovered to that before a power cut or de-energizing, but may change depending on the operating environment.
Troubleshooting ○Troubleshooting When any failure occurs with this product, the following chart can be used to identify the cause of the failure. If a cause applicable to the troubles cannot be identified and normal operation is recovered by replacement with a new product, this indicates that the product itself was faulty. Problems with the product may be due to the operating environment (installation etc).
Page 73
The display is Refer to Trouble No.7 Displayed value is not unstable. correct Refer to Trouble No.9 The display turns OFF. Refer to Trouble No.9 The display is missing. Refer to Trouble No.10 Display flashes. There are differences in the displayed values Refer to Trouble No.11 when using more than one product.
Page 74
○Troubleshooting list Problem Problem possible Problem Investigation method Countermeasures causes •The switch (1) Check the set pressure value. output does not (2) Check the settings of the (1) Adjust the set pressure turn OFF. operation mode, hysteresis and value. The operation Incorrect output type.
Page 75
Problem Problem possible Problem Investigation method Countermeasures causes (1) Check if the output current is 80 (1)(2) Connect the mA or more. appropriate load. (2) Check if the connected load (3) Use a relay with a surge complies with the specification. Excess current voltage suppressor or Check if the load is short circuited.
Page 76
Problem Problem possible Problem Investigation method Countermeasures causes Applied voltage Check the pressure range setting. Incorrect does not match Check if the connected pressure Select the correct pressure pressure range with the displayed sensor and the set pressure range range. setting pressure value.
Page 77
Problem Problem possible Problem Investigation method Countermeasures causes Unit s selection function is not available for fixed to SI Model selection units type. (model selected Check if the product number printed Display (kPa↔MPa is available) does not have on the product indicates units measurement ∗: The units selection function is units selection...
Page 78
○Error indication function This function is to display error location and content when a problem or error has occurred. Error Error displayed Description Measures Turn the power off and remove Over current The switch output load current is 80 mA the cause of the over current.
Specifications Product No. PSE3##A series Rated pressure range Display/set pressure range Refer to the table for each pressure specification (page 79) Display/min. setting unit Power supply voltage 12 to 24 VDC ±10%, ripple max. 10% (p-p) Current consumption 35 mA or less Protection Polarity protection Display accuracy...
Page 80
Product No. PSE3##A series ∗4 Unit Select from MPa, kPa, Pa, kgf/cm , bar, mbar, psi, inHg, mmHg or mmH2O Display type Number of displays 3-screen display (Main display, sub display x 2) 1) Main display: Red/Green Display colour 2) Sub display: Orange Main display: 4 digit (7-segments) Number of display digits Sub display: 4 digit (Upper 1 digit 11-segments, 7-segments for other)