Draminski 1QMast Operation Manual

Mastitis detector

Advertisement

Quick Links

MASTITIS DETECTOR
model: 1QMast, 4Q Mast, 4x4Q Mast
4Q Mast
4x4Q Mast
1Q Mast
OPERATION MANUAL
www.draminski.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1QMast and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Draminski 1QMast

  • Page 1 MASTITIS DETECTOR model: 1QMast, 4Q Mast, 4x4Q Mast 4Q Mast 4x4Q Mast 1Q Mast OPERATION MANUAL www.draminski.com...
  • Page 2: Table Of Contents

    CONTENTS 1. INTRODUCTION……………………………………………………………………… 3 2. CONSTRUCTION…...………………………………………………………………… 4 3. OPERATION…………………………………………………………………………… 7 4. MEASUREMENTS…………………………………………………………………….10 5. INTERPRETATION OF RESULTS…………………………………………………. 14 6. BATTERY REPLACEMENT…………………………………………………………. 15 7. TECHNICAL DATA…………………………………………………………………… 16 8. END NOTES…………………………………………………………………………… 16...
  • Page 3: Introduction

    CONSTRUCTION ELECTRONIC DETECTOR OF SUBCLINICAL MASTITIS IN COWS: Currently, there are three models of Mastitis detectors are available: • Enables the rapid detection of subclinical mastitis in a large number of cows, directly 1. Model : 4x4 Q MAST in the cowhouse just before milking. It allows appropriate preventive steps to be made that could prevent the disease from its transition into a clinical condition.
  • Page 4 2. Model: 4Q MAST 3. Model: 1Q MAST The device consists of a one measurement vessel (cup) with electrodes, electronic unit with LCD panel, handle containing a standard 9 volt battery marked as: 6F22 and a The device consists of a one measurement vessel (cup) with electrodes, electronic unit switch.
  • Page 5: Operation

    OPERATION 2. Model: 4Q MAST The display indicates the proper work of the device. The first checkout of the detector 1. Model: 4x4Q MAST should be conducted with no milk in the cup, in the ‘empty air’, when electrodes are spaced.
  • Page 6: Measurements

    3. Model: 1Q MAST MEASUREMENTS The display indicates the proper work of the device. The first checkout of the detector Before starting your measurement the following should be done: should be conducted with no milk in the cup, in the ‘empty air’, when electrodes are 1.
  • Page 7 Measurements are made in the following way: 8. The detector is automatically switched off after 30 seconds of idle operation following the last pressing of the switch. Model: 4x4Q MAST The device may be also switched off by pressing and holding the switch for more than 3 seconds.
  • Page 8: Interpretation Of Results

    Note ! INTERPRETATION OF RESULTS Rinsing should also be completed after testing a quarter in which a subclinical condition has been detected. That way, residues of milk from that sample will IT IS NECESSARY TO EVALUATE RESULTS ACCORDING TO TWO CRITERIA: not affect the measurement of another quarter.
  • Page 9: Battery Replacement

    quarter A = 340 TECHNICAL DATA quarter B = 350 quarter C = 350 Weight - approx. 450 g (4x4Q Mast) quarter D = 260 a result below 300 units and a difference of 90 units - approx. 300g (4Q Mast, 1Q Mast) compared to the highest result (quarters B and C) an old cow, 9 lactation,...