Summary of Contents for Datalogic PowerScan 7000BT SRI
Page 1
® PowerScan 7000BT SRI Linear Imager Quick Reference Guide...
Page 2
Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Con- tact Datalogic" page.
Statement of Agency Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two con- ditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Class B Compliance Statement The user is cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment.
Agreement. If you do not intend to be bound to the terms of this Agree- ment, Datalogic is not willing to license the Software to you, you may not use the Datalogic Product or the Software, and you must contact the party from whom you acquired the Datalogic Product for instructions.
Page 5
Datalogic Scanning, Inc., Legal Department, 111 SW Fifth Ave. Suite 4100, Portland, OR 97204-3644. In the defense or settlement of any such claim, Datalogic may, at its option, 1) procure for End User the right to continue using the Datalogic Product, 2) modify the Datalogic Product so that it becomes non-infringing,...
252.227-7013(c)(1)(ii), whichever is applicable. If End User is using the Datalogic Product outside of the United States, End User must comply with the appli- cable local laws of the country in which the Datalogic Product is used, with U.S. export control laws, and with the English language version of this Agreement.
Table of Contents Statement of Agency Compliance ............i FCC Class B Compliance Statement ........... i FCC RF Radiation Exposure Statement ......... i Canadian Notice ................i Power Supply ................. i Solids and Water Protection ............ii Software Product Policy ............... iv Laser Cautions ................
Getting Started Installing the Battery Pack To charge the Battery Pack, See “Battery Pack Charging and Maintenance” on page 7. Datalogic recommends annual replacement of NOTE rechargeable battery packs to ensure maximum performance. Do not discharge the battery using any device except for the scan- ner.
Page 10
Always charge the battery at 32° – 113°F (0° - 45°C) temperature range. Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any other CAUTION power supplies can damage the linear imager and void your war- ranty.
Getting Started Figure 1. Battery Pack Installation & Removal Scanner Alignment Pins Battery Pack Release Latch Release Latch Verifying Scanner Operation Before Linking to the Base Station Once a charged Battery Pack has been installed in the scanner, scan a good sample bar code of the symbology type your scanner is pro- grammed to read.
) to prevent undue strain on the socket. Figure 2 This Base Station MUST be used with a Datalogic approved power supply. It is not designed to obtain its power off of the terminal (POT). Connection to a host terminal without first connecting the external power supply may result in damage to the terminal.
Getting Started Host Connection — The interface type was specified at the time your scanner was ordered, however you should verify before connection that the scanner’s cable type is compatible with your host equipment. Most connections plug directly into the host device as shown in .
Page 14
ascending tones from the scanner. A “high-low-high-low” tone indicates the link attempt was unsuccessful. A single LED flash during this tone indicates no Base Station was discovered. Two green LED flashes during this tone indicates that more than one Base Station was discovered and the scanner did not link.
4. On the PC, search for Bluetooth devices that are in range and select the “Datalogic PS7000 Scanner.” 5. Connect with the serial port for the Datalogic PS7000 Scanner. Note which serial port number is assigned to the scanner. 6. Open your serial port application and connect to the scanner using the serial port that was assigned in the previous step.
There presently are no US, North America or World disposal require- ments for Lithium-Ion batteries such as the Battery Pack, so when they won't hold a charge anymore they can be disposed of; preferably through a recycling center. Contact your local government for disposal or recy- cling practices in your area.
Getting Started Interface Selection Select the desired interface by scanning the associated bar code below. For Keyboard Wedge interfaces, see for a listing of associated Table 1-1 keyboard types. INTERFACE SELECTION BARCODE RS-232 Standard RS-232 Wincor-Nixdorf Wand Emulation IBM 4683 Port 5B IBM 4683 Port 9B...
Page 19
Getting Started IBM 3153 IBM 316X, 3179/3180/319X/3270 IBM 3151/3152-010, 347X/348X DIGITAL VT 220/320/330/340/350/382 DIGITAL VT420 DIGITAL VT 510/520 IBM ANSI Style Keyboard DIGITAL VT 510/520 IBM PC Style Keyboard SUN SPARC 5/10 SUN 420/440, ITX Reference the Product Reference Guide (PRG) for more information about keyboard support.
Page 20
Keyboard Wedge H Keyboard Wedge I Keyboard Wedge J Keyboard Wedge K Keyboard Wedge L Keyboard Wedge M Keyboard Wedge N Keyboard Wedge O Keyboard Wedge P Keyboard Wedge Q Keyboard Wedge R PowerScan® 7000BT SRI...
Getting Started Keyboard Wedge S Keyboard Wedge T Keyboard Wedge U Keyboard Wedge V Keyboard Wedge W Keyboard Wedge X Resetting the Standard Product Defaults If programming settings for your scanner are in an unknown condition, factory settings can be restored by scanning the “Standard Product Default Settings”...
How to Scan When the trigger is pressed, the scanner projects a red, horizontal illumi- nating beam. This beam will remain on until the trigger is released, a bar code is read, or until a time-out period expires. If the surface being scanned is highly reflective (e.g., laminated), it may be necessary to tilt the item or the scanner slightly (15°...
Troubleshooting Figure 6. Scanning Bar Codes Decrease..or Increase distance from bar code to adjust aiming beam width to cross all bars. Stacked Sweep stacked bar codes slowly and smoothly from top to bottom (or bottom to top). Troubleshooting Troubleshoot your scanning system by performing the following checks: Troubleshooting the RF System For the RF system, ensure...
• the scanner is linked to the desired Base Station. See "Linking the Scanner to a Base Station" on page 5 • the scanner is within reasonable operating range of the Base Sta- tion, with no major obstructions between the radio units such as thick walls or heavy machinery.
Page 25
Troubleshooting • are enabled in the scanner. See the Product Reference Guide (PRG) for more about configuring the scanner to read symbolo- gies). • Is the bar code displayed but not entered? The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return or Tab key, for example).
Page 26
• The scanner sounds other than a standard “Good Read” beep fol- lowed by an “Acknowledge ” beep when reading a bar code (indi- cating the bar code has been read and properly transmitted). • Verify the scanner is linked to and within range of its Base Sta- tion.
Page 27
Equipment Type: Barcode Scanning Equipment Products: PowerScan 7000BT family with Dock Placed into EU Service: April 2007 under the Datalogic trademark. October 2006 under the PSC trade- mark. Responsible Datalogic Scanning, Inc. 959 Terry St. Eugene, OR USA Manufacturer: Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC English: This equipment is in compliance with the essential requirements &...