Download Print this page

OPTEX FA Fastus UR-DS4AD Instruction Manual

Io-link hub analog i/o module

Advertisement

Quick Links

For technical support of Optex IO-LINK contact Ramco Innovations today. Got an application and need help? - email us at nsales@ramcoi.com
INSTRUCTION MANUAL
IO-Link Hub Analog I/O Module
UR-DS4AD
(4-input)
OPTEX FA CO., LTD.
Thank you for purchasing the UR-DS4AD IO-Link Analog 4-input Module.
This manual includes the information required to use the UR-DS4AD. Please
read this manual carefully before use, and fully understand the functions and
performance before using this product correctly. Also, keep this manual in a
safe place after reading it, and always keep it handy.
Safety Precautions
Safety precautions for ensuring safe operation of this product are displayed as
follows with the following symbols.
Precautions listed here describe important information about safety. Make sure
to follow them accordingly.
Safety Symbols
Indicates that any improper operation or handling may
result in moderate or minor injury, and in rare cases,
WARNING
serious injury or death. Also indicates a risk of serious
property damage.
Indicates that any improper operation or handling may
CAUTION
result in minor injury or property damage.
WARNING
Do not disassemble, repair, modify, deform under pressure or attempt
to incinerate this product.
Doing so may cause injury or fire.
Do not use this product in water or in a location where it may be exposed to
water. Do not use this product if wet.
Doing so may cause a fire or damage the product.
This product is not explosion-proof and should not be used around
flammable or explosive gases or liquids.
Doing so may cause ignition resulting in an explosion or fire.
Do not use air dusters or any spray that uses flammable gas around the
product or on the inside of the product.
Doing so may cause ignition resulting in an explosion or fire.
Do not use this product in environments other than industrial environments.
If used in other environments, it may cause induction and radiation interference.
Do not install this product or its cables in any of the following locations.
Doing so may cause a fire, damage or a malfunction.
1. Locations where dust, salt, iron powders or vapor (steam) is present.
2. Locations subjected to corrosive gases or flammable gases.
3. Locations where water, oil or chemical splashes may occur.
4. Locations where heavy vibrations or impacts may occur.
5. Locations where the ambient temperature exceeds the rated range.
6. Locations subject to rapid temperature changes
(or where condensation occurs).
7. Locations with strong electric or magnetic fields.
8. Outdoor locations or locations subject to direct light.
Do not use the product at voltages or with AC power supplies that
exceed the rated voltage.
Doing so may cause a fire or damage the product.
What to do in the event of a malfunction such as smoke being emitted
from the product:
If you detect any malfunction including emission of smoke, abnormal
smells or sounds or the body becoming very hot, immediately stop
operating the product and turn off the power.
Failure to do so can cause fire.
Repairing the product is dangerous and should in no way be performed
by the customer. Contact an OPTEX FA sales representative for repairs.
What to do if water enters the product:
If water or any other liquid enters the product or the cable, immediately
stop operating the product and turn off the power. Using the product in
this condition may cause a fire.
0813951
CAUTION
Do not touch this product or the cable with wet hands. Incorrect wiring
can cause product failure or malfunction.
When wiring this product, do so properly according to this manual and
specified instruction manuals.
Incorrect wiring can cause product failure or malfunction.
Connect only specified cables to this product.
Use of cables other than those specified can cause malfunction.
Keep wiring separate from high voltage and motor circuits. Using the
same wiring can cause malfunction or failure.
If this is unavoidable, shield with a conductor such as an earthed
conduit.
Install this product as far away as possible from high-voltage
equipment, equipment that generates large switching surges and
equipment that generates noise, such as welding machines or inverter
motors.
Use this product with the end plate (sold separately) mounted to the
DIN rail.
Make sure locking mechanisms are locked before use.
Tighten the mounting screws that attach the power terminal block to the
main unit with a torque value of 0.25 N•m or less.
Do not apply torsional stress to cables. Doing so can cause cables and
connectors to malfunction.
Secure the communications cable drawn out of this product within
lengths of 30 cm to ensure no load is applied to the product.
Do not drop this product or subject it to strong impact or vibrations.
Doing so can cause malfunction.
This product generates heat during operation, so do not maintain
physical contact for long periods of time.
Doing so can cause low-temperature burns, etc.
Use this product within the rated range.
Do not cut power during communication.
Make sure to turn OFF the power before connecting or disconnecting
cables and connectors. Connection or disconnection while running can
cause malfunction.
Always hold the connector when connecting or disconnecting cables
and do not apply excessive force to cables.
When removing a connector, do not touch the terminals inside the
connector or allow foreign objects to get inside.
When using power cables or commercially available switching
regulators, make sure the frame ground (FG) is grounded.
Wait until after transient state (approx. 2 sec.) when power is turned ON
before use.
Make sure to use an isolation transformer for DC power supply.
If a surge occurs in the power supply used, use a surge absorber for the
source of generation.
If this product used in a manner not specified by the manufacturer, the
protection provided by this product may be impaired.
1. Overview
IO-Link Analog I/O Module UR-DS4AD is a remote analog input unit that
specifies 4 analog input signals to control various actuators with process input
data from the IO-Link master.
It can be used to control devices with analog output, such as changing the
speed of a motor, or adjusting flow rate or fan speed.
2. Included Items
UR-DS4AD unit
This instruction manual
Input terminal block: two pieces
Power terminal block: one piece
Ramco Innovations
3. Dimensions
85
4. Installation
Follow the steps below to install this product.
1. Hook the upper hook on the back of the product to the DIN rail.
2. Push the lower side from the front.
3. Push the DIN rail mounting hook up to lock the product in place.
DIN rail
Push-in
DIN rail mounting hook
Install this product at least 10 mm away from an adjacent device and
structure.
5. System Configuration
Configuration software
for field network
communication
UR Master Manager
Field network master
Field network communication
OPTEX FA IO-Link Master, UR Series
IO-Link communication
・・・
IO-Link device
www.optex-ramco.com
(800) 280-6933
6. Connection
█ Wiring to the IO-Link master
(39.9)
21.5
Connect the IO-Link master to either the e-CON socket on this
product or the push-in terminal block (power/IO-Link terminal block).
• Connecting to the IO-Link communication e-CON socket
e-CON socket for IO-Link communication (4 poles)
24 V
NC
0 V
C/Q
Applicable wires should be between AWG 28 to 20 stranded wires with
a rated temperature of 75°C or higher.
• Connecting to the IO-Link communication terminals on the power
terminal block
Power terminal block
Connect to the following IO-Link communication power and the C/Q terminals
Unit (mm)
Unit power supply 24 V
IO-Link communication C/Q (*1)
Unit power supply 0 V
Note 1: C/Q is connected internally with the IO-Link communication e-CON socket.
Applicable wires should be between AWG 24 to 12 stranded wires with
a rated temperature of 75°C or higher.
The length of stripped insulation from the wire for rod type crimp terminal,
solid or stranded wires is from 9 to 10 mm.
█ Wiring to the analog input power supply
Supply power to input devices to the push-in terminal block.
Power terminal block
Applicable wires should be between AWG 24 to 12 stranded wires with
a rated temperature of 75°C or higher.
The length of stripped insulation from the wire for rod type crimp
terminal, solid or stranded wires is from 9 to 10 mm.
█ Wiring to the analog input terminal block
Connect the wires for power supply and input signal of input devices
to the 16-channel push-in terminal blocks.
Input terminal block
Applicable wires should be between AWG 28 to 16 stranded wires with
a rated temperature of 75°C or higher.
The length of stripped insulation from the wire for rod type crimp
terminal, solid or stranded wires is 10 mm.
Output devices
(4-input)
IO-Link Analog 4-input Module
(this product)
e-CON plug
To IO-Link Master
L+
M
I/O
Electric wire insertion port (round hole)
Open/close key (orange)
To IO-Link master
Electric wire insertion port (round hole)
Open/close key (orange)
Supply output power to a pair of the following.
Analog output power supply L+
Analog output power supply L+
Analog output power supply M
Analog output power supply M
Open/close key (orange)
Electric wire insertion port (round hole)
LED
From left to right
Corresponds to
voltage input,
output 0 to 3
analog GND,
sequentially from
current input,
the left.
and shield GND
For power supply to analog output
device (M: 0 V, L+: 24 V)

Advertisement

loading

Summary of Contents for OPTEX FA Fastus UR-DS4AD

  • Page 1 Failure to do so can cause fire. (4-input) ・・・ Repairing the product is dangerous and should in no way be performed by the customer. Contact an OPTEX FA sales representative for repairs. UR-DS4AD unit This instruction manual What to do if water enters the product: ●...
  • Page 2 Vibration resistance IEC 61131-2 compliant endian format. The IO-Link master UR series from OPTEX FA transfers IO-Link process data converted * This equipment has been tested and found to comply with the limits for a Class A dig- Shock resistance IEC 61131-2 compliant ital device, pursuant to part 15 of the FCC Rules.