Misting system

Advertisement

Quick Links

INTRODUCTION
If you received this manual as part of the Misting Kit, please see page 5. For all other applications, continue on...
The Pro-Watch Misting System is a liquid dispenser designed to automatically spray predetermined volumes of
chemicals such as deodorants and odor suppressants into trash compactors, trash bins, or any other application
requiring chemical treatment. The microprocessor timer activates the peristaltic pump which pushes liquid through a
spray nozzle, permitting large areas of waste to be treated.
The Pro-Watch uses an MT-300 control, capable of up to 20 separate run events per day. Each event can run for up
to 16 minutes. The MT-300 also has a security feature to prevent accidental or unauthorized programming changes,
and an "onboard" battery (with 5-year life) keeps the current time setting in the event of main power loss. All
programmed information is saved in non-volatile memory.
INSTALLATION
APPLICATION NOTE: Do not use system in freezing temperatures.
(1) Mount the unit on a wall using the supplied mounting bracket (customer must supply hardware to install).
Choose a mounting location near both the injection point and chemical supply. CAUTION: Do not mount the unit
in the direct path of steam. This can short circuit and permanently damage your system.
(2) If applicable, connect main power wires as shown in the wiring diagram on page 3, and per local electrical
codes. Failure to do so will void warranty.
(3) Mount the spray nozzle assembly (horizontal or vertical) in the desired location. Do not remove the green
protective cap from the nozzle while mounting — it prevents damage to the spray tip from tools or handling.
(4) Install poly tubing between the pickup tube and the input (left) side of the pump's squeeze tube. Use a hose
clamp to secure poly tubing to the squeeze tube. Be sure to draw poly tubing through the end of the pickup tube.
(5) Insert the footvalve (strainer) into the bottom of the poly tube.
(6) Install poly tubing between the output (right) side of the pump's squeeze tube and the elbow fitting on the spray
nozzle assembly. Push the poly tubing into the elbow fitting to secure it. Use a hose clamp to secure poly tubing
to the squeeze tube.
(7) Remove the green protective cap mentioned in step 3.
(8) To prime the pump, insert the pickup tube into the chemical container and press the "PRIME 1" button on the
front cover of the system. The pump will run as long as the button is pressed.
HOW TO EASILY CALCULATE PUMP RUN TIMES
The pump dispenses about 3 ounces per minute under normal operation with the nozzle in place. The actual flow
rate of the pump will vary depending on product viscosity, tubing distance, and other factors. The steps below will
help you in determining the run time required to dispense the volume needed for your application.
(1) Make sure the chemical lines (both the pickup side and output side of the pump) are fully primed.
(2) Place a beaker or measuring cup under the spray nozzle, then hold down the PRIME 1 button for 30 seconds.
(3) Check the volume dispensed into your container and multiply by 2 — this will determine the actual flow rate of
the pump in oz/minute.
(4) Use this flow rate to determine how long you will need the pump to run to delivery the dosage required for your
application.
0900905 Rev: F (03/02)
352:$7&+0,67,1*6<67(0
,16758&7,210$18$/
Page 1 of 8

Advertisement

Table of Contents
loading

Summary of Contents for Idex Knight Pro-Watch

  • Page 1 352:$7&+0,67,1*6<67(0 ,16758&7,210$18$/ INTRODUCTION If you received this manual as part of the Misting Kit, please see page 5. For all other applications, continue on... The Pro-Watch Misting System is a liquid dispenser designed to automatically spray predetermined volumes of chemicals such as deodorants and odor suppressants into trash compactors, trash bins, or any other application requiring chemical treatment.
  • Page 2: Operation Notes

    OPERATION NOTES • During normal operation, the clock will display briefly when a run event starts, or while PRIME button is pressed. • During programming, if a button is not pushed within 2 minutes, the display will disappear and the control will return to normal operation.
  • Page 3: Wiring Diagram

    WIRING DIAGRAM 0900905 Rev: F (03/02) Page 3 of 8...
  • Page 4 SPRAY NOZZLE DIAGRAM IMPORTANT: If the nozzle assembly is ever disassembled from the push-connect fitting, the threads of the push-connect fitting should be coated with pipe thread sealant (Knight P/N 1900203 or equivalent) before re-assembling. Page 4 of 8 0900905 Rev: F (03/02)
  • Page 5 MISTING KIT OVERVIEW The Misting Kit includes all parts necessary to convert a standard Pro-Watch dispenser to a Misting System. Use of this kit is only recommended for Pro-Watch systems that have a transformer (internal or external) and is not intended for use with battery-operated versions.
  • Page 6: Troubleshooting

    TROUBLESHOOTING Pump runs too slowly: No power: Check roller block for binding. Check the in-line fuse to the power transformer. Check the voltage at the transformer. Check voltage (24 VDC applied to the pump motor terminals will result in the highest speeds). Check input terminals on board for loose screws and correct input voltage.
  • Page 7 NOTES: 0900905 Rev: F (03/02) Page 7 of 8...
  • Page 8: Warranty

    Warranty does not cover liability resulting from performance of this equipment nor the labor to replace this equipment. Product abuse or misuse voids warranty. .1,*+7 ,1& A Unit of IDEX Corporation World Headquarters: 20531 Crescent Bay Drive, Lake Forest, CA 92630-8825 (USA) TEL: 949-595-4800, FAX: 949-595-4801, www.knightequip.com Atlanta Branch:...

Table of Contents