IBM eServer BladeCenter 8677 Installation And User Manual page 73

Table of Contents

Advertisement

3
5
6 7
8
1
2
4
MAC MAC MAC
1a
2a
3a
1b
2b
3b
Note: 2nd switch module is optional
Each blade server has two independent Ethernet controllers, each with its own
MAC address and a dedicated 1000-Mbps link to one of the switch modules
(Controller 1 to Switch A and Controller 2 to Switch B in this diagram). In this
configuration (the default), the blade servers share access to four external ports on
each switch. There is no internal data path between the two switches within the
BladeCenter chassis; an external network device is required for data packets to flow
from one internal switch to the other.
The management module has a separate internal 100-Mbps link to each switch.
These links are for internal management and control only. No data packets are
allowed to flow from application programs on the blade servers to the management
module over this path. A separate, non-switched path (not shown) is used for
communication between the management module and a service processor on each
blade server.
A typical, preferred BladeCenter network topology is shown in the following
illustration. See the IBM Eserver BladeCenter Planning and Installation Guide for
more information and other topologies and guidelines.
1 Gbps links
Switch A
9 10 11 12 13 14
Mgmt
Mod
Switch B
1 Gbps links
Chapter 4. Configuring your BladeCenter unit
1 Gbps or
100 Mbps links
10/100 Mbps
100 Mbps
links
57